Quest Dry 132D 

Installation, Operation and Maintenance Instructions

  

1

2

3

9

10

11

12

13

8

4

5

6

7. Service Parts List

Item   Part No. 

Description

4025076 

FAN, MOTORIZED IMPELLER, PROCESS AIR

4035235-07  CAPACITOR, RUN, 15 MFD, 370V, DRY, PROCESS AIR

4019652 

COLLAR, 6” (2 PLACES)

4026315 

FILTER, AIR, 12 X 12 X 1, REACTIVATION AIR

4026798 

FAN, MOTORIZED IMPELLER, REACTIVATION AIR

4037807 

HEATER KIT, DESICCANT

4026898 

THERMAL OVERLOAD, PROCESS AIR

4035235-11  CAPACITOR, RUN, 8 MFD, DRY, REACTIVATION AIR

10 

1970010 

RELAY SPST 110VAC COIL (2)

11 

4026773 

MOTOR, DESICCANT WHEEL

12 

4026795 

BELT, DRIVE, QUEST DESICCANT

13 

4026772 

WHEEL, DESICCANT

15 

4021475 

FILTER, AIR, 16 X 20 X 2, PROCESS AIR

16 

4026194 

SWITCH, ROCKER, DPST, ON-OFF

17 

4025043 

PLATE, SKID

18 

4032315 

CORD (2 PLACES)    

  
Not 

4026922 

GASKET AND BELT REPLACEMENT KIT   

 

Shown  4036559 

3A CIRCURT BREAKER 

 

4022484 

RELAY, SPST, 24VAC COIL 

 

4022487 

TRANSFORMER, 120V/24V, 40VA 

18

1-800-533-7533 

Quest DRY 115 

Installation, Operation and Maintenance Instructions

  

www.thermastor.com

[email protected]

quest

Asset Protection and IAQ Solutions

quest

9

0

8

5

6. Service Parts List

Item   Part No. 

Description

1  4025076 FAN, MOTORIZED IMPELLER, PROCESS AIR

2  4025224 CAPACITOR, RUN, 15 MFD, 370V, DRY, PROCESS AIR

3  4019652 COLLAR, 6” (2 PLACES)

4  4026860 FILTER, AIR, 12 X 12 X 1, REACTIVATION AIR

5  4026798 FAN, MOTORIZED IMPELLER, REACTIVATION AIR

6  4026799 HEATER CORE

8  4926898 THERMAL OVERLOAD CUT-OUT SWITCH, PROCESS AIR

9  4026830 CAPACITOR, RUN, 8 MFD, DRY, REACTIVATION AIR

10 1970010 CONTROL RELAY SPST 110VAC COIL 25AMP CONTACTS (2)

11 4026773 MOTOR, DESICCANT WHEEL

12 4026795 BELT, DRIVE, PHOENIX DESICCANT

13 4026772 WHEEL, DESICCANT

14 4028077 THERMAL OVERLOAD CUT-OUT SWITCH, REACTIVATION AIR

15 4021475 FILTER, AIR, 16 X 20 X 2, PROCESS AIR

16 4026194 SWITCH, ROCKER, DPST, ON-OFF

17 4025043 PLATE, SKID

18 4025078 CORD, 14/3. SjT, 115V W/PLUG 25’ (2 PLACES)   

 

Not 4026922  GASKET AND BELT REPLACEMENT KIT   

 

Shown  

5

8

16

Summary of Contents for Dry 132D

Page 1: ...ion Factory installed 115VAC power cords 2 required 15 Amps each Simple ON OFF operation with optional low voltage control for remote dehumidistat operation Vertical or horizontal operation Multiple ducting options Water Removal Rates Pints Day 65 Pints 100 F 20 180 Pints 90 F 90 150 Pints 80 F 80 132 Pints 80 F 60 AHAM 130 Pints 70 F 80 120 Pints 70 F 60 120 Pints 60 F 80 115 Pints 60 F 60 125 Pi...

Page 2: ...side Drying Space 5 3 Operation 5 3 1 How the Quest DRY 155 Works 5 3 2 Controlling the Quest Dry 132D 6 4 Maintenance 6 4 1 Air Filters 6 4 2 Blower Motors and Rotor Drive Motor 7 4 3 Desiccant Rotor Cassette Assembly 7 5 Service 7 5 1 Warranty 7 5 2 Technical Description 7 a Main Components 7 b Control Circuit 8 c Safety Components 8 5 3 Normal Operation 8 5 4 Troubleshooting 8 6 Wiring Diagram ...

Page 3: ...rk passes through a cold space the duct must be insulated to prevent condensation from forming inside the duct Le Quest Dry 132D est conçu pour être installé SEULEMENT À L INTÉRIEUR Lorsqu utilisée près d une zone d eau l unité doit être branchée sur des circuits DDFT N UTILISEZ PAS le Quest Dry 132D comme banc ou table Évitez d évacuer l air de procédé directement vers les gens Cet appareil ne do...

Page 4: ... Reactivation Duct 6 Start collars included Process Duct 8 Start collars included External Static 0 0 4 WC Process Pressure 0 0 25 WC Reactivation Warranty 1 Year Parts and Labor Low temperature performance is dependent on reactivation air source Supplying warmer reactivation air will significantly increase water removal Dimensions Unit Shipping Width 20 25 Height 36 47 Depth 20 24 Weight 105 Lb 1...

Page 5: ...ing spaces Keeps separation between air inside and air outside of drying space c Outside Drying Space Requires process air to be ducted out from and back into drying space Works well if drying space is too small for mounting unit inside Reduces heat load on drying space 3 Operation The Quest Dry 132D comes complete and can be plugged in and turned on Connected this way the Quest Dry 132D will run ...

Page 6: ...tched on the unit will run When the terminals are not electrically connected the unit will not run Remove the factory installed jumper before installing an external control If the jumper is not removed the Quest Dry 132D will operate continuously as described in 3 2 a IMPORTANT Line voltage controls that interrupt power to the unit may not be used with the Quest Dry 132D The unit uses an internal ...

Page 7: ...f removal Cassette Removal Instructions 4 0 6 1 RELAY 2 4 0 6 1 LOW V RELAY 4 0 6 1 24VAC TRANSFORMER GRN TRANSFORMER PRIMARY EXTERNAL CONTROL TRANSFORMER SECONDARY 3ABREAKER LOW V RELAY COIL TERMINAL BLOCK EXTERNAL CONTROL 3A BREAKER 1 2 4 2 Blower Motors and Rotor Drive Motor All motors on the 132DD are permanently lubricated and do not require maintenance 4 3 Desiccant Rotor Cassette Assembly T...

Page 8: ...n inlet temperature is too high or if there is insufficient reactivation airflow the automatically resetting heater cutout opens and all loads are de energized Once the temperature drops by a few degrees F the switch closes again and the loads are re energized The second heater cutout has a higher temperature limit and only trips if the automatically resetting switch hasn t opened This higher cuto...

Page 9: ... No continuity across low voltage control terminals 4 Thermal cutout s tripped Unplug unit and allow to cool Identify and correct problem before plugging unit back in 5 Defective relay s 6 Wiring fault inside device Blowers and heater operating rotor not turning 1 Rotor unplugged 2 Belt broken or not properly tensioned Adjust or replace belt 3 Pulley not fixed to driveshaft Tighten or replace set ...

Page 10: ...RG 31 YEL 20 RED 18 VIO 15 VIO 27 BLK 2 BLK 10 VIO 14 WHT 13 WHT 22 WHT 23 BLU 21 BLU 7 BLU 25 BLU 25 YEL 19 VIO 33 ORG 30 YEL 32 BLK 17 BLK 1 BLU 29 BLU 21 TERMINAL BLOCK WHT22 BLK28 WHT 23 1 2 3 4 LINE LINE ROCKER SWITCH POLE 1 ROCKER SWITCH POLE 2 NEUTRAL 24VAC COM NEUTRAL RELAY 1 CONTACT LOW V RELAY CONTACT 1270W HEATER 1360W HEATER HEATER CUTOUT 1 RELAY 2 COIL PROCESS CAPACITOR HEATER CUTOUT ...

Page 11: ...T BREAKER 4022484 RELAY SPST 24VAC COIL 4022487 TRANSFORMER 120V 24V 40VA 18 1 800 533 7533 Quest DRY 115 Installation Operation and Maintenance Instructions www thermastor com sales questprotect com quest Asset Protection and IAQ Solutions quest 9 0 8 5 6 Service Parts List Item Part No Description 1 4025076 FAN MOTORIZED IMPELLER PROCESS AIR 2 4025224 CAPACITOR RUN 15 MFD 370V DRY PROCESS AIR 3 ...

Page 12: ... tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC reasonable control Limitations and Exclusions If any Quest Dry 132D Dehumidifier part is repaired or replaced the new part shall be warranted for only the remainder of the original warranty period applicable thereto but all warranty periods will be extended by t...