14. Configuration Parameters
Parameter no. 1
–
In-wall Switch Type for Load (
) to control I1
With this parameter, you can select between push-button (momentary) and on/off toggle
switch types.
Values (size is 1 byte dec):
•
default value 0
•
0 - push-button (momentary)
•
1 - on/off toggle switch
Parameter no. 5
–
Working mode
With this parameter, you can change the device presentation on the user interface.
Values (size is 1 byte dec):
•
default value 0
•
0 - Dimmer mode
•
1 - Switch mode (works only in 3 way wiring-connection with neutral line)
ⓘ
NOTE: After parameter change, first exclude the device (without setting parameters to
default value) then wait at least 30s before reinclusion.