9. Electrical Diagram (110 - 240VAC, 24-30VDC)  

3-Wired System 

2-Wired System 

 

 

 
 

Notes for diagram:  

Neutral wire (+VDC)

 

Live (line) wire (-VDC)

 

 

Output for electrical device 

 

Input for switch/push button *

 

Service button (used to add or remove the device from the Z-Wave network) 

LED  When the Mini Dimmer is excluded: 

 

green LED is blinking (1 sec ON, 1 sec OFF) 

 

red LED is ON if overload occurs 

 

red LED is blinking (1sec ON, 1 sec OFF) if over temperature occurs 

 

blue LED is blinking (1 sec ON, 1 sec OFF) when calibration is in progress 

 

blue LED is ON if calibration fails 

When the Mini Dimmer is included: 

 

green LED is ON 

 

red LED is ON if overload occurs 

 

red LED is blinking (1sec ON, 1 sec OFF) if over temperature occurs 

 

blue LED is blinking (1 sec ON, 1 sec OFF) when calibration is in progress 

 

blue LED is ON if calibration fails 

 

Summary of Contents for ZMNHHD1

Page 1: ...world most compact dimmer MOSFET switching light device that also supports control of low voltage halogen lamps with electronic transformers dimmable compact fluorescent lights and dimmable LED bulbs...

Page 2: ...lights 12 3 1 Advantages 12 3 2 Highlights 16 4 Package Contents 17 5 Technical Terms for Switches 18 6 Compatibility with Z Wave Gateways hubs 19 7 Installation 21 7 1 Installing the device behind a...

Page 3: ...EN 3 18 Important Disclaimer 57 19 Warning 57 20 Regulations 57 240VAC240VAC...

Page 4: ...additional features and parameters for you to play with We love helping people who enjoy creating new ideas for their home and then using their hard work and skill to turn those ideas into reality We...

Page 5: ...us reading applications in residential and light commercial environments Mature proven and broadly deployed with over 50 million products sold worldwide Z Wave is by far the world market leader in wir...

Page 6: ...stalling the device follow the instructions exactly The manufacturer GOAP d o o Nova Gorica shall not be legally responsible for any equipment damage or personal injury caused by incorrect installatio...

Page 7: ...z 868 4 MHz ZMNHHD7 50 Hz 919 8 MHz ZMNHHD8 50 Hz 865 2 MHz ZMNHHD9 60 Hz 922 5 MHz ZMNHHDA 60 Hz 920 9 921 7 923 1 MHz ZMNHHDB 50 Hz 919 8MHz ZMNHHDC 60 Hz 868 4 MHz ZMNHHDD 60 Hz 919 8 MHz ZMNHHDE 5...

Page 8: ...upports push button momentary switches default and toggle switches It can work with or without the neutral line Qubino Mini Dimmer allows the easiest and quickest installation The Qubino Mini Dimmer a...

Page 9: ...EN 9...

Page 10: ...project Of course there are countless of other options for how to use Qubino Mini Dimmer to remotely control devices via your smartphone 2 1 Installation examples where Mini Dimmer is installed behin...

Page 11: ...This function is independent of other scenes and gateway hub commands Do you know how much energy you consume The Mini Dimmer monitors and reports energy consumption of connected devices in real time...

Page 12: ...vely utilised compared to other dimmers on the market Example dimming a halogen bulb of max illuminance of 100 lux and setting the dimming value to 100 Illuminance Classic dimming in a 3 Wired system...

Page 13: ...ll this is possible because the Qubino Mini Dimmer is the smallest Z Wave dimmer in the world This means it can be mounted fast and easy behind a classic switch which reduces assembly time and install...

Page 14: ...with minimum power loads that are bigger than 0 W valid only in case of 3 wired connection Qubino guarantees 100 device quality Such high quality can be delivered because every Qubino goes through rig...

Page 15: ...The serial and part numbers of your device are given automatically every time you open an inquiry with our support team this instantly shares the relevant device information we need to provide the be...

Page 16: ...ures one of the easiest and quickest installations of devices of this kind fits in even the smallest flush mounting boxes Saves and restores the last status after a power failure Supports auto inclusi...

Page 17: ...EN 17 4 Package Contents Mini Dimmer Device Installation Manual S2 packaging label...

Page 18: ...h Switch Bi stable switch Single pole double throw SPDT Two switches controlling the same light circuit of lights Two way switch Three way switch Two way switch Used when you have three or more switch...

Page 19: ...teway hub before you purchase this device The compatibility table is in preparation for any information please contact us at http qubino com support email NOTE This device must be used in conjunction...

Page 20: ...EN 20...

Page 21: ...e device s terminals NOTE Do not connect the device to loads exceeding the recommended values Connect the device exactly as shown in the provided diagrams Improper wiring may be dangerous and result i...

Page 22: ...nt electrical shock and or equipment damage disconnect electrical power at the main fuse or circuit breaker before installation and maintenance Be aware that even if the circuit breaker is off some vo...

Page 23: ...EN 23 Step 2 Installing the device Connect the device exactly according to the diagrams shown below Before Qubino installation...

Page 24: ...EN 24 After Qubino installation Connection without a neutral line 2 Wired system...

Page 25: ...EN 25 Connection with a neutral line 3 Wired system...

Page 26: ...EN 26 INSTALLATION WITH 2 OR MORE SWITCHES CONTROLLING THE SAME LIGHT Before Qubino installation...

Page 27: ...EN 27 2 WAY SWITCH...

Page 28: ...EN 28 MULTI WAY SWITCHES...

Page 29: ...om metal elements as they may cause signal interference Do not shorten the antenna The device s antenna should be as upright as possible This ensures the device s operational range is maximized up to...

Page 30: ...EN 30 Step 4 Add the device to your Z Wave network For more details on how to include the device please refer to the Z Wave Inclusion chapter...

Page 31: ...EN 31 Step 5 The Installation is now complete It s time to make your life more comfortable with the help of the Qubino Mini Dimmer...

Page 32: ...the device page for more information If you still don t find what you re looking for click on the link to Qubino technical support team They will be able to automatically read the serial and part num...

Page 33: ...d green LED is blinking 1 sec ON 1 sec OFF red LED is ON if overload occurs red LED is blinking 1sec ON 1 sec OFF if over temperature occurs blue LED is blinking 1 sec ON 1 sec OFF when calibration is...

Page 34: ...te allows the device to receive network infromation from the controller NOTE For S2 inclusion please check chapter 17 Z Wave Security NOTE Please wait at least 30 seconds between each inclusion and ex...

Page 35: ...ice will be removed from your network but any custom configuration parameters will not be erased NOTE LEARN MODE state allows the device to receive network infromation from the conttoller NOTE Please...

Page 36: ...GNALIZATION FOR INCLUSION EXCLUSION LED green LED is blinking 1 sec ON 1 sec OFF module is excluded LED is ON module is included LED red LED is OFF normal operation LED is ON overload LED is blinking...

Page 37: ...r it after each power cycle even if the module is included you need to set the correct value in parameter 71 Calibration Trigger With parameter 72 you can also check the calibration status in case the...

Page 38: ...ote that this command class is active only in switch mode 2 Basic OnOff 16 Supports the following command classes Basic set triggered at change of output and reflecting its state 3 StartStop level cha...

Page 39: ...the output and the overload notification is sent In case the parameter 70 is disabled the Mini Dimmer has also a fixed overload safety value of 220W to prevent any damage to the module Also in this c...

Page 40: ...ue 0 0 push button momentary 1 on off toggle switch Parameter no 5 Working mode With this parameter you can change the device presentation on the user interface Values size is 1 byte dec default value...

Page 41: ...value 0 0 Auto OFF Disabled 1 32536 1 32536 seconds Auto OFF timer enabled for a given amount of seconds Parameter no 12 Turn Load 1 On Automatically with Timer If Load is OFF you can schedule it to t...

Page 42: ...value 0 0 double click disabled 1 double click enabled Parameter no 30 Restore on off status for load after power failure This parameter determines if on off status is saved and restored for the load...

Page 43: ...ared to the last reading Values size is 1 byte dec default value 10 0 Power consumption reporting disabled 1 100 1 100 Power consumption reporting enabled New value is reported only when Wattage in re...

Page 44: ...every 300 seconds or 5 minutes if there was a change compared from the last report Values size is 2 byte dec default value 0 0 Power consumption reporting on time interval disabled 30 32767 30 32767se...

Page 45: ...ng value is set by entering a value NOTE The minimum level may not be higher than the maximum level Parameter no 61 Maximum dimming value The value set in this parameter determines the maximum dimming...

Page 46: ...ault value 1 1s 1 127 1 seconds 127 seconds step is 1 second Parameter no 66 Dimming time when key hold Choose the time during which the Dimmer will move between the min and max dimming values during...

Page 47: ...3 Values size is 1 byte dec default value 0 0 use the start level value 1 ignore the start level value NOTE Parameter is valid only in Dimmer mode In Switch mode the parameter has no effect Parameter...

Page 48: ...can be turned back on by input I1 or sending a control frame Values size is 2 byte dec default value 200 1 200 1 W 200W 0 function not active NOTE This functionality is not an overload safety protecti...

Page 49: ...s Values size is 1 byte dec default value 2 calibration failed 1 calibration was successful 2 calibration failed Parameter no 73 Alarm Notification events This parameter defines the module behaviour i...

Page 50: ...r defines the time interval of the blinking state once the module receives an alarm notification event Minimum step increase is 1 minute Values size is 1 byte dec default value 10 10 minutes 1 125 1 1...

Page 51: ...indoors 98 ft Dimensions WxHxD package 38x33 5x15 5mm 79x52x22mm Weight with package 28g 34g Electricity consumption 0 4W Mounting 60 mm 2 36 in or 2M depth 60 mm 2 36 in Switching MOSFET Trailing ed...

Page 52: ...according to the diagram To restore the dimmer to its regular operation please power cycle the device When overload occurs an Over load detected notification is sent to the gateway hub Maximum Power L...

Page 53: ...ulb CFL low voltage halogen bulbs with electronic transformer LED 40W 240VAC 20W 110VAC CFL LVH Electronic transformer 70W 240VAC 35W 110VAC Low voltage halogen bulbs with conventional transformer Oth...

Page 54: ...V2 COMMAND_CLASS_SECURITY_V1 COMMAND_CLASS_SECURITY_2_V1 COMMAND_CLASS_VERSION_V2 S0 S2 COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 S0 S2 COMMAND_CLASS_POWERLEVEL_V1 S0 S2 COMMAND_CLASS_MANUFACTURER_SPECIFI...

Page 55: ...Enabled Z Wave Plus Product can be included and operated in any Z Wave network with other Z Wave certified devices from any other manufacturers All constantly powered nodes in the same network will a...

Page 56: ...inserted in the packaging which must not be lost Do not remove the DSK from the product As a backup measure use the label in the packaging The first five digits of the key are highlighted or underline...

Page 57: ...us substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new ones the retailer is legally obligated to take back y...

Page 58: ...of P N Example P N ZMNHHDxHxS2Px GOAP d o o Nova Gorica Ulica Klementa Juga 007 5250 Solkan Slovenia E mail info qubino com Tel 386 5 335 95 00 Web www qubino com Date 29 03 2019 V 1 8 1 DON T MISS O...

Reviews: