12. Associations
Use associations for direct communication between the Mini Dimmer and other devices within
your Z-Wave network without the need of your primary gateway (hub).
Association Groups:
Root device:
ID
Name
Allowed
nodes
Description
1
Lifeline
1
Supports the following command classes:
•
Device Reset Locally: triggered upon request
•
Meter Report: triggered according to Configuration
parameters 40 and 42
•
Notification Report: triggered on overload/over
temperature
•
Switch Multilevel Report: triggered upon request or
according to Configuration parameters 11 and 12
(note that this command class is active only in
dimmer mode)
•
Switch Binary Report: triggered upon request or
according to Configuration parameters 11 and 12
(note that this command class is active only in switch
mode)
2
Basic OnOff
16
Supports the following command classes:
•
Basic set: triggered at change of output and
reflecting its state
3
StartStop level
change
16
Supports the following command classes:
•
Start/Stop Level Change: triggered upon holding and
releasing the switch connected to I1
4
Multilevel set
16
Supports the following command classes:
•
Switch Multilevel Set: triggered at change of output
and reflecting its state
ⓘ
NOTE: Association 3 StartStop level change is switch type dependant. The switch must be a
bi-stable switch type otherwise the association can not be trigered. To know how to chnae the
switch type connected please refer to chapter Configuration parameters for more information.
ⓘ
NOTE: When the device is in switch mode (parameter 5 set to 1), association groups 3 and 4
have are not available. Please refer to chapter Configuration parameters for more information.
Summary of Contents for ZMNHHD1
Page 3: ...EN 3 18 Important Disclaimer 57 19 Warning 57 20 Regulations 57 240VAC240VAC...
Page 9: ...EN 9...
Page 17: ...EN 17 4 Package Contents Mini Dimmer Device Installation Manual S2 packaging label...
Page 20: ...EN 20...
Page 24: ...EN 24 After Qubino installation Connection without a neutral line 2 Wired system...
Page 25: ...EN 25 Connection with a neutral line 3 Wired system...
Page 27: ...EN 27 2 WAY SWITCH...
Page 28: ...EN 28 MULTI WAY SWITCHES...