11. Removing the device from a Z-Wave network
(Exclusion)
REMOVAL FROM A ZWAVE NETWORK (Z-WAVE EXCLUSION)
1. Connect the device to the power supply
2. Make sure the device is within direct range of your Z-Wave gateway (hub) or use a hand-
held Z-Wave remote to perform exclusion
3. Enable add/remove mode on your Z-Wave gateway (hub)
4. Toggle the switch connected to the I1 terminal 3 times within 3 seconds
OR
If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2
and 6 seconds
5. The device will be removed from your network but any custom configuration parameters
will not be erased
FACTORY RESET
1. Connect the device to the power supply
2. Within the first minute (60 seconds) the device is connected to the power supply, toggle the
switch connected to the I1 terminal 5 times within 3 seconds (5 times change switch state).
OR
If the device is powered by 24 V SELV supply, press and hold the S (Service) button for at least 6
seconds
ⓘ
By resetting the device, all custom parameters previously set on the device will return to
their default values, and the owner ID will be deleted. Use this reset procedure only when the
main gateway (hub) is missing or otherwise inoperable.
Summary of Contents for ZMNHDD2
Page 18: ...EN 18 4 Package Contents Flush Dimmer Device Installation Manual...
Page 25: ...EN 25 After Qubino installation Wiring with one switch...
Page 26: ...EN 26 INSTALLATION WITH ON OFF SWITCH AND SCENE SWITCHES...
Page 27: ...EN 27 INSTALLATION WITH 3 WAY SWITCH...
Page 29: ...EN 29 2 WAY SWITCH...
Page 30: ...EN 30 MULTI WAY SWITCHES...
Page 31: ...EN 31 INSTALLATION WHERE THERE IS NO NEUTRAL LINE N IN SWITCH BOX Before Qubino installation...
Page 32: ...EN 32 After Qubino installation...
Page 38: ...EN 38 Step 2 Switch of the power supply Step 3 Connect the temperature sensor as shown below...
Page 39: ...EN 39 Step 4 Place the temperature sensor in the switch box Step 5 Turn the fuse on...
Page 40: ...EN 40 Step 6 Re include the device to your network...
Page 41: ...EN 41 Step 7 Start using the temperature sensor in connection with your device...