Step 2 

 Switch of the power supply  

 

Step 3 

 Connect the temperature sensor as shown below  

 

 

Summary of Contents for ZMNHDD2

Page 1: ...NO FLUSH DIMMER The Qubino Flush Dimmer is a MOSFET switching light device that also supports control of low voltage halogen lamps with electronic transformers dimmable compact fluorescent lights and...

Page 2: ...s 17 4 Package Contents 18 5 Technical Terms for Switches 19 6 Compatibility with Z Wave Gateways hubs 21 7 Installation 22 7 1 Installing the device behind a light switch 23 7 2 Installing the Qubino...

Page 3: ...additional features and parameters for you to play with We love helping people who enjoy creating new ideas for their home and then using their hard work and skill to turn those ideas into reality We...

Page 4: ...us reading applications in residential and light commercial environments Mature proven and broadly deployed with over 50 million products sold worldwide Z Wave is by far the world market leader in wir...

Page 5: ...stalling the device follow the instructions exactly The manufacturer GOAP d o o Nova Gorica shall not be legally responsible for any equipment damage or personal injury caused by incorrect installatio...

Page 6: ...69 0 MHz ZMNHDD5 50 Hz 916 0 MHz ZMNHDD6 50 Hz 868 4 MHz ZMNHDD7 50 Hz 919 8 MHz ZMNHDD8 50 Hz 865 2 MHz ZMNHDD9 60 Hz 922 5 MHz ZMNHDDA 60 Hz 919 7 921 7 923 7 MHz ZMNHDDB 50 Hz 868 1 MHz ZMNHDDC 60...

Page 7: ...and dimmable LED bulbs It measures power consumption of the connected device and can be paired with a digital temperature sensor sold separately It supports push button momentary switches and toggle...

Page 8: ...sh Dimmer supported functions Dim the Lights Turn on off kWh Measurement W Measurement Temperature Sensor Automatically turn ON OFF Scene 1 Trigger Scene 2 Trigger Associations Z Wave Repeater Auto in...

Page 9: ...ourse there are countless of other options for how to use Qubino Flush Dimmer to remotely control devices via your smartphone 2 1 Installation examples where Flush Dimmer is installed behind a wall sw...

Page 10: ...EN 10 Remotely measure room temperature The temperature sensor is sold separately for more info please see Qubino catalogue Product ordering code model number ZMNHEA1...

Page 11: ...et period of time when you re away from home For example the light will automatically turn off if it s been on for 8 hours let s say This function is independent of other scenes and gateway hub comman...

Page 12: ...ces in your Z Wave network with the Flush Dimmer Connect the Flush Dimmer with other devices in your network to remotely and automatically trigger another Z Wave device And have other Z Wave devices t...

Page 13: ...he ambient air or water temperature It s the only Z Wave dimmer in the world which offers this option With a connected sensor the user can monitor accurate measurements of the room temperature pool wa...

Page 14: ...Home turn on all the lights in the house o Switch connected to input I3 Leaving Home turn off all the lights in the house Qubino Dimmer allows a direct connection of even the smallest bulbs It s the...

Page 15: ...ing procedure By scanning the QR code on the back of your Qubino device the serial and part numbers will be automatically copied on your mobile phone they also provide direct access to Qubino s techni...

Page 16: ...ineered and manufactured in the EU and contains only the highest quality components The Qubino Flush Dimmer is certified by an independent European Institute and has CE FCC LVD and EMC certificates to...

Page 17: ...ush mounting boxes Saves and restores the last status after a power failure Supports auto inclusion mode for quick set up Can automatically turn devices on and off after a set period of time helpful w...

Page 18: ...EN 18 4 Package Contents Flush Dimmer Device Installation Manual...

Page 19: ...h Switch Bi stable switch Single pole double throw SPDT Two switches controlling the same light circuit of lights Two way switch Three way switch Two way switch Used when you have three or more switch...

Page 20: ...20 Qubino devices are installed into flush mounting boxes behind the switches You can see some examples below For more information on how to install your device please refer to the Installation chapt...

Page 21: ...s UI I3 updates UI W Measurements kWh Measurements Temperature Measurements Comments Domoticz V3 5877 Fibaro HC Lite v 4 100 Vera edge v 1 7 2406 Zipato 1 1 38 Z Wave me Homeseer 3 0 0 313 Open Z Wave...

Page 22: ...in equipment damage Electrical installation must be protected by directly associated overcurrent protection fuse 1A gG or Time lag T rated breaking capacity 1500A ESKA 522 717 must be used according...

Page 23: ...nt electrical shock and or equipment damage disconnect electrical power at the main fuse or circuit breaker before installation and maintenance Be aware that even if the circuit breaker is off some vo...

Page 24: ...EN 24 Step 2 Installing the device Connect the device exactly according to the diagrams shown below Before Qubino installation...

Page 25: ...EN 25 After Qubino installation Wiring with one switch...

Page 26: ...EN 26 INSTALLATION WITH ON OFF SWITCH AND SCENE SWITCHES...

Page 27: ...EN 27 INSTALLATION WITH 3 WAY SWITCH...

Page 28: ...EN 28 INSTALLATION WITH 2 OR MORE SWITCHES CONTROLLING THE SAME LIGHT Before Qubino installation...

Page 29: ...EN 29 2 WAY SWITCH...

Page 30: ...EN 30 MULTI WAY SWITCHES...

Page 31: ...EN 31 INSTALLATION WHERE THERE IS NO NEUTRAL LINE N IN SWITCH BOX Before Qubino installation...

Page 32: ...EN 32 After Qubino installation...

Page 33: ...om metal elements as they may cause signal interference Do not shorten the antenna The device s antenna should be as upright as possible This ensures the device s operational range is maximized up to...

Page 34: ...EN 34 Step 4 Add the device to your Z Wave network For more details on how to include the device please refer to the Z Wave Inclusion chapter...

Page 35: ...EN 35 Step 5 The Installation is now complete It s time to make your life more comfortable with the help of the Qubino Flush Dimmer...

Page 36: ...ected directly to power supply Install it and forget it there is no need to worry about changing the batteries like with most other Z Wave temperature sensors which run on batteries The temperature se...

Page 37: ...EN 37 Temperature sensor installation example Step 1 Exclude the device if it is already connected to your Z Wave system...

Page 38: ...EN 38 Step 2 Switch of the power supply Step 3 Connect the temperature sensor as shown below...

Page 39: ...EN 39 Step 4 Place the temperature sensor in the switch box Step 5 Turn the fuse on...

Page 40: ...EN 40 Step 6 Re include the device to your network...

Page 41: ...EN 41 Step 7 Start using the temperature sensor in connection with your device...

Page 42: ...the device page for more information If you still don t find what you re looking for click on the link to Qubino technical support team They will be able to automatically read the serial and part num...

Page 43: ...e sensor only for Flush Dimmer device compatible digital temperature sensor which must be ordered separately S Service button WARNING The S Service button must NOT be used when the device is connected...

Page 44: ...ADDING THE DEVICE TO A Z WAVE NETWORK MANUAL INCLUSION 1 Enable add remove mode on your Z Wave gateway hub 2 Connect the device to the power supply with the temperature sensor already connected 3 Tog...

Page 45: ...nd 6 seconds 5 The device will be removed from your network but any custom configuration parameters will not be erased FACTORY RESET 1 Connect the device to the power supply 2 Within the first minute...

Page 46: ...input up to 16 nodes Group 9 Notification report status change report for I3 input up to 16 nodes Group 10 Binary sensor report status change report for I3 input up to 16 nodes Group 11 Multilevel se...

Page 47: ...to 16 nodes Group 4 Binary sensor report status change of the I3 input up to 16 nodes End point 4 External Temperature Sensor Group 1 Lifeline group 0 nodes allowed Group 2 Multilevel sensor report ex...

Page 48: ...e is 1 byte dec default value 0 0 push button momentary 1 on off toggle switch Parameter no 2 In wall Switch Type for Load 1 Q1 to control I2 With this parameter you can select between a push button m...

Page 49: ...Values size is 1 byte dec default value 0 0 NO normally open input type 1 NC normally close input type Parameter no 4 Input 3 contact type Values size is 1 byte dec default value 0 0 NO normally open...

Page 50: ...L ON not active ALL OFF active 2 ALL ON active ALL OFF not active Parameter no 11 Turn Load 1 Q Off Automatically with Timer If Load 1 Q is ON you can schedule it to turn OFF automatically after a per...

Page 51: ...ize is 2 byte dec default value 0 0 Auto ON Disabled 1 32535 1 32535 seconds Auto ON enabled with define time step is 1 second Parameter no 20 Enable Disable the 3 way switch additional switch Dimming...

Page 52: ...lue 0 0 double click disabled 1 double click enabled Parameter no 30 Restore on off status for Q load after power failure This parameter determines if on off status is saved and restored for the load...

Page 53: ...set in this parameter compared to the previous Wattage reading starting at 1 the lowest value possible NOTE Power consumption needs to increase or decrease by at least 1 Watt to be reported REGARDLES...

Page 54: ...be higher than the maximum level 1 min dimming value is defined by the Z Wave multilevel device class Parameter no 61 Maximum dimming value The value set in this parameter determines the maximum dimmi...

Page 55: ...icSet Values size is 2 byte dec default value 100 1s 50 255 500 milliseconds 2550 milliseconds 2 55s step is 10 milliseconds Parameter no 66 Dimming time when key pressed Choose the time during which...

Page 56: ...his parameter is used with association group 3 Values size is 1 byte dec default value 0 0 use the start level value 1 ignore the start level value Parameter no 68 Dimming duration Choose the time dur...

Page 57: ...OTIFICATION_SENSOR Values size is 1 byte dec default value 0 1 Home Security Motion Detection unknown location 2 CO Carbon Monoxide detected unknown location 3 CO2 Carbon Dioxide detected unknown loca...

Page 58: ...ze is 1 byte dec default value 0 1 Home Security Motion Detection unknown location 2 CO Carbon Monoxide detected unknown location 3 CO2 Carbon Dioxide detected unknown location 4 Water Alarm Water Lea...

Page 59: ...an external sensor sold separately This parameter only applies to Celsius temperature unit the Fahrenheit unit is currently not supported Values size is 2 byte dec default value 32536 32536 Offset is...

Page 60: ...elsius temperature unit the Fahrenheit unit is currently not supported Values size is 1 byte dec Default value 5 0 5 C 0 Reporting disabled 1 127 Where 1 stands for 0 1 C and 127 stands for 12 7 C Par...

Page 61: ...r supports secure and unsecure inclusion If the gateway hub does not enable the device to be included as secure it is included as unsecure while retaining the same functionality Values size is 1 byte...

Page 62: ...age 41 8x36 8x16 9 mm 79x52x22 mm 1 65x1 45x0 66 in 3 11x2 05x0 87 in Weight with package 28g 34g 0 98oz 1 20oz Electricity consumption 0 7W For installation in boxes 60 mm 2 36 in or 2M depth 60 mm 2...

Page 63: ...h electronic or conventional transformers Dimmable compact fluorescent bulb CFL If the bulb flickers set parameter 60 minimum dimming value to value 30 or more Dimmable LED bulbs Conventional incandes...

Page 64: ...COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_POWERLEVEL_V1 COMMAND_CLASS_SECURITY Securely Supported Command Classes COMMAND_CLASS_SWITCH_ALL_V1 COMMAND_CLASS_SWITCH_BINARY_V1 COMMAND_CLASS_SE...

Page 65: ...ER_SWITCH_MULTILEVEL Command Classes COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_SECURITY COMMAND_CLASS_ASSOCIATION_2 COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2...

Page 66: ...CLASS_MULTI_CHANNEL_ASSOCIATION_V3 COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 COMMAND_CLASS_SENSOR_BINARY_V1 COMMAND_CLASS_NOTIFICATION_V5 COMMAND_CLASS_MARK COMMAND_CLASS_BASIC_V1 Endpoint 3 I3 Device Cla...

Page 67: ...S_INFO_V2 COMMAND_CLASS_SECURITY COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 COMMAND_CLASS_SENSOR_MULTILEVEL_V7 NOTE The Endpoint 3 co...

Page 68: ...e BASIC_SET command To be turned ON Command Class Basic Basic Set Basic Value 0x01 0x63 in percentage FF set to last value To be turned OFF Command Class Basic Basic Set Basic Value 0x00 COMMAND_CLASS...

Page 69: ...les Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause...

Page 70: ...te electrical and electronic equipment Directive do not dispose of this product as household waste or commercial waste Waste electrical and electronic equipment should be appropriately collected and r...

Reviews: