O
PERATION
Harmony
Ball Return Manual
–
400-254-022
34
Rev. Date 3/16
8.4
SOFTWARE
QubicaAMF will occasionally develop new and improved software for the Harmony Ball Return
to improve particular features and enhance the overall functionality of the lift. It is
recommended that each ball return have the latest available software installed. To load
software:
1.
Go to QAMF’s FTP site (
ftp://qcustomer:[email protected]/BallLift/
and download the software file to the root directory of a USB thumb drive. All software
updates are in the form of UPD files.
Be sure that the most recent software is the only UPD file on the thumb drive.
2.
Confim the control unit is
connected to AC power before
beginning the update process.
3.
Remove the ball return hood and
clear the hood error by pressing the
MODE SELECT button.
4.
Wait for the control box to
calibrate. Calibration is finished
once the BALL EXIT and INTRUSION
LEDs are no longer flashing.
Note that the LEDs will not
stop flashing in the event of a control box failure.
5.
Insert the thumb drive into the USB port on the side of the control box (shown above).
6.
The unit will immediately write a log file to the thumb drive. Once complete, the BALL
EXIT and INTRUSION LEDs will alternately flash green. The LEDs remain flashing during
steps #7 and #8.
7.
Unplug the thumb drive.
8.
Reinsert the thumb drive into the USB port.
9.
Press and release the MODE SELECT button. The unit will begin to reprogram itself.
10.
Once reprogramming is complete, red will begin flashing in sequence across the LEDs.
This indicates that the software has loaded.
If the BALL EXIT LED is the only LED flashing red; the software did not load
properly.
11.
Unplug the thumb drive.
12.
Press the MODE SELECT button.
13.
Close the hood.
14.
The control box will recalibrate once more and then function with the newly loaded