O
PERATION
Harmony
Ball Return Manual
–
400-254-022
33
Rev. Date 3/16
When an error occurs, the STATUS LED will blink red and an alarm will sound. Press the MODE
SELECT button to clear an error and enter MANUAL mode. The various errors are listed below.
Additionally, refer to the Stop Code Decal on the upper rail.
Error
Description
LEDs
STA
TU
S
IN
TR
US
IO
N
BA
LL
E
X
IT
BA
LL
E
N
TR
Y
1. Lift Control
Overheat
The control box’s thermal
protection has been activated.
Internal temperature has
exceeded 203°F (95°C).
2. E-STOP
The E-STOP button has been
pressed.
3. Hood Opened
The hood has been removed.
4. Ball Entry
Failure
Ball Entry sensor has been
activated for 10+ seconds.
5. Intrusion Board
Calibration Failure
The intrusion board failed to
calibrate.
6. Intrusion Board
Failure
Communication between the
control box and the intrusion
board has failed.