QUATRO
Air Technologies Inc.
Fresh Air Purifiers
-----------------------------------------------------------------------------------------------
Engineers Of Clean Air
UV Light Installation - AF1000
Tools required
:
•
#3 Philips screwdriver
OR
•
#2 Robertson screwdriver
Caution: Never expose eyes or skin to UV-C energy.
Warning
: Before installing or servicing the UV-C lights,
turn unit power off
.
Note: there is a kill switch that serves this function, as an extra safety precaution.
Note
: UV-C light bulbs should be
replaced annually
. Visible blue light is not an indication of
UV-C output; UV-C wavelength is invisible.
1. Turn off your AF1000-IVF unit.
2. Open the unit door; Use your screwdriver to unfasten the (2) screws securing it.
Material
Part Number
UV-C Light bulb (pack of 4)
#E718
Spare Filter
(
Note:
UV-C lights are packaged
and placed in the bottom
compartment of the unit to remain
safe during shipping.