7. Insert the new UV-C lightbulb [#E718] into the power supply socket; secure by hand
tightening the clamp nut to create an interference fit.
8. Insert the UV light assembly into the mounting ring.
Note: Make sure to observe alignment slots on the mounting ring, allowing for an easy fit.
9. Pull up on the yellow safety latch. Turn the UV light assembly clock-wise (Note: approx.
60 degrees CW until installed). Push down on the yellow safety latch to lock into
mounting ring.
10. Align the power cap and twist on; Clockwise rotation until you hear it snap into place.
11. Close the unit door and secure by fastening the screws back into place.
For visual purposes, the
HEPA filter above the
UV-C light bulb has
been removed.