9.3 

POSITIONING OF UNIT 

 

Mounted  on  four  casters,  the  unit  can  be  wheeled  virtually  anywhere  in  the  room  for  optimal  convenience.  The  unit  is  designed  in  an  up-flow 
configuration allowing the air to create a "sweeping" effect across the room. The clean air is released from top of unit, moving across the room in a 
downward motion. The clean air pushes particulate and gaseous matter towards the floor level and draws it in the intake grille located at bottom of 
unit. This configuration allows the particles which have already accumulated towards the ground to be pulled towards the return air grille. This results 
in a very effective means of space cleaning. The 

AF iSeries Purifier

 is more efficient the closer it is placed to its intended source. Conversely, the 

unit's efficiency is diminished as it is placed further from the source of pollutants. 

 

 

9.3 

REDUCTION IN AIRFLOW 

As the unit cleans the air, the filters are removing the submicronic particles and dust from the air stream.  As the filters accumulate debris (both visible 
and microscopic), a restriction on the blower/motor is created.  As the restriction becomes greater, the air capacity delivered by the blower decreases 
rendering the unit less effective.  IT IS VERY IMPORTANT TO CHANGE FILTERS ON A REGULAR BASIS. 
 

 

10.0 

TROUBLESHOOTING GUIDE 

Symptoms 

Possible Cause 

Suggested Solution 

Unit will not start 

o Faulty Power supply 
o Blown fuse 
o Unit not plugged into receptacle 

o Check breaker box 
o Replace fuse 
o Plug unit in 

Excessive noise 

o Blower wheel contacting cone 
o Fan isolators loose or off 

o Realign/replace wheel 
o Replace isolator 

Insufficient airflow 

o Obstruction in system 
o Clogged filters 

o Remove obstruction 
o Replace filters 

Excessive airflow 

o Filters not in place 

o Install filters 

 

11.0 

WARRANTY 

QUATRO Air Technologies warrants its equipment to be free from defect in material and workmanship under normal use and service for a 
period of one year from date of shipment.  QUATRO's obligation under this warranty shall be limited to replacing any parts, thereof, which shall 
be demonstrated to have been defective.  This is expressly in lieu of all other warranties, express or implied, including the warranties of 
merchantability and fitness. 
QUATRO claims no warranty as to merchantability or as to the fitness of the merchandise for any particular use and shall not be liable for any 
loss or damage.  No person, firm or corporation is authorised to assume for QUATRO any other liability in connection with the sale of these 
goods.  Equipment, parts and material manufactured by others and incorporated in QUATRO's equipment are warranted by QUATRO only to 
the extent of the original manufacturer's liability to QUATRO Air Technologies Inc. 
Conditions and Limitations: 

This warranty does not cover

 abuse, misuse, maintenance negligence, improper assembly, acts of vandalism, acts of God, fear wear, 

modifications of the equipment or installation of a part not recommended by QUATRO Air Technologies, as well as operation of the equipment at 
voltages other than those specified by QUATRO Air Technologies Inc. 
 
 
 
 
 
 

Summary of Contents for AF Series

Page 1: ...ntenance Keep all fastening hardware tight to ensure that the unit is in good working condition Familiarise yourself with the way in which filters are removed installed and serviced All filters must b...

Page 2: ...ited if airflow is obstructed c Insert male end of cord into the correct voltage circuit Control will emit 3 beeps and 4 LEDs will flash along with those beeps d Press Power button and adjust airflow...

Page 3: ...ust be taken not to damage the exposed portions of the new HEPA filter DO NOT bend aluminium separators as this will obstruct airflow j RESET Service Filter s Light see section 8 6 8 3 Optional CHEMIC...

Page 4: ...ptimum efficiency ensure all casters are tightly fastened The motor is equipped with electric motor grade double shielded ball bearings and a special lubricant assuring long life and quiet operation N...

Page 5: ...Remote Control subD 9 pin connector can purchase an optional foot pedal switch part AA175 to turn unit on off remotely Also pins 1 and 2 can be wired to any dry contact switch for remote on off capabi...

Page 6: ...not plugged into receptacle o Check breaker box o Replace fuse o Plug unit in Excessive noise o Blower wheel contacting cone o Fan isolators loose or off o Realign replace wheel o Replace isolator Ins...

Page 7: ...on system complete with adjustable inlet grill and adjustable discharge grills installed If it is desired to operate as a negative pressure system the 6 AF1000 or the 10 AF2000 discharge collars will...

Page 8: ...he cutting drilling process If you decide not to replace the HEPA filter you must place something on top of the filter to protect against the metal shavings dropping into the filter Step 2 Remove the...

Page 9: ...he unit Step 7 Use the self tapping screws to fix the plate on to the top of the unit permanently For units built with serial numbers greater than 75288 the 3 black grills will be mounted on a separat...

Page 10: ...re is a kill switch that serves this function as an extra safety precaution Note UV C light bulbs should be replaced annually Visible blue light is not an indication of UV C output UV C wavelength is...

Page 11: ...r cap counter clockwise and remove 4 Slide out the yellow safety latch 5 Twist the power supply counter clockwise and remove the UV light assembly 6 Loosen the clamp nut and remove the old UV C lightb...

Page 12: ...alignment slots on the mounting ring allowing for an easy fit 9 Pull up on the yellow safety latch Turn the UV light assembly clock wise Note approx 60 degrees CW until installed Push down on the yel...

Reviews: