nanoTX
TM
Telemetry Transmitter
52
Quasonix, Inc.
Mnemonic
Command
Name
Description
Option (s)
Required
Setting
Saved?
Factory
Default
RA or RN
Randomizer
Report or set randomizer state
Examples:
RA
Report the randomizer
state
RA 0
Set randomizer OFF
RA 1
Set IRIG-106 randomizer
ON
RA 2
Set CCSDS randomizer
ON
Standard
RA 2
requires
LD6
option and
LDPC
enabled
Y
RA 0
RC
(or PP or
RL)
Recall
Configuration
Load a saved configuration into
the active configuration if the
configuration number entered is
valid
If the selected configuration has
no valid data or the command is
issued without a configuration
number, the transmitter is
initialized with the default data
and saved.
Example:
RC
Load configuration 0
(default setup)
RC 3
Load configuration 3
Standard
N/A
N/A
RF
RF Output
Report or set RF output control
state
Note that there may be no RF
output, even if the software
control is set to ON. This can
happen if there is no valid clock in
use, or if the RF on/off hardware
pin is in the OFF state.
Examples:
RF
Report the RF output
state
RF 0
Set RF output OFF
RF 1
Set RF output ON
Standard
Y
RF 1
(if option
CP07,
default is
RF 0)