nanoTX
TM
Telemetry Transmitter
42
Quasonix, Inc.
Mnemonic
Command
Name
Description
Option (s)
Required
Setting
Saved?
Factory
Default
CF
Clock Free
Report or set the clock free state.
Examples:
CF
Report the clock free
state
CF 0
Unit uses its internal bit
sync (internally synthesized)
CF 1
Unit uses its externally
applied clock
CF
Y
CF 1
CP
Clock Polarity
Report or set clock polarity
Examples:
CP
Display the current clock
polarity
CP 0
Set clock polarity to NOT
inverted
CP 1
Set clock polarity to
inverted
CP A Set clock polarity to auto;
Automatically selects the most
reliable clock edge
Standard
Y
CP 0
CR
Current Preset
Read
Reports the currently selected
software preset being used by the
transmitter
Standard
N/A
N/A
CS
Clock Source
Report or set the clock source
Unit always reverts to CS 0
(external) at power-up
Examples:
CS
Display the current clock
source
CS 0
Set clock source to
external
CS 1
Set clock source to
internal
When set to internal clock source,
the data source must also be set
to internal via the DS command in
order to have synchronous,
usable data.
Standard
N
CS 0