nanoTX
TM
Telemetry Transmitter
45
Quasonix, Inc.
Mnemonic
Command
Name
Description
Option (s)
Required
Setting
Saved?
Factory
Default
H (or HE)
Help
Displays a list of available
commands
Commands require a carriage
return at the end of the line and
may also accept parameters
Some commands may not be
enabled depending on required
options
Standard
N/A
N/A
HP
High Power
Report or set high power level
Valid range is 0-31 in 1 dB steps
or 0-31.5 in 0.5 dB steps,
depending on the transmitter
Examples:
HP
Report the present high
power level
HP 31 Set high power to 31
HP Max Set high power to the
highest allowable value for the
unit
HP Min Set high power to the
minimum allowable value for the
unit
DP
Y
HP 31
HX
eXtended Help
Displays a full list of available
commands
Standard
N/A
N/A