nanoTX
TM
Telemetry Transmitter
50
Quasonix, Inc.
Mnemonic
Command
Name
Description
Option (s)
Required
Setting
Saved?
Factory
Default
MC
NRZ-M
Conversion
Enables or disables the NRZ-L to
NRZ-M conversion
Examples:
MC
Show the current NRZ
state
MC 1
Enable the NRZ-L to
NRZ-M conversion
MC 0
Disable the NRZ-L to
NRZ-M conversion
CE
Y
MC 0
MJ
Modulation
Scaling Step
Size
Sets the current modulation
scaling factor used when the
single key Power Step Up and
Power Step Down functions are
used
Valid range is .0009 to 10.01
MS
Y
MJ 1.5
MO
Modulation
Report or set modulation setting
Mode 6, Carrier only, is present
on every transmitter
Examples:
MO
Report the modulation
setting
MO 0 Set modulation to
PCM/FM
MO 1 Set modulation to
SOQPSK-TG
MO 2 Set modulation to MULTI-
h CPM
MO 6 Carrier only, no
modulation
Standard
Y
MO 0 or
the first
one the
customer
has
installed
on the
unit
Example:
MO 1 if
no
PCM/FM
installed;
MO 2 if
only
CPM
installed
MS
Modulation
Scaling
Scales the deviation (modulation
index) of the transmitted signal
relative to the standard default
deviation
Example:
For PCM/FM
– if the standard
modulation index is 0.7, setting
MS to 2.0 scales a modulation
index of 1.4
Value range is .09 to 128.01
MS
Y
MS 1