Quark-Elec IS20 Manual Download Page 8

 

 

 

IS20 Manual                                                     

 

 

 

V 1.0 

8  of  23 

2023 

 
 

4.1.  Power and NMEA 0183 input/output connector 

The IS20 uses industry standard six-core screened M12 cable for power supply and NMEA 0183 
input/output connection. 

It operates on a 12V DC power supply. To properly connect the IS20, please follow these guidelines: 
Connect the red wire to the positive supply (12V) using a 2-amp fuse, and securely connect the black 
wire to the ground (GND). It is crucial to avoid connecting any of the other data wires to the 12V power 
source, as doing so could potentially damage the device. Rest assured, the IS20 is equipped with 
reverse polarity protection, ensuring the device remains safeguarded in the event of a faulty installation. 

The IS20 can also be powered through the NMEA 2000 port using an N2K cable. When utilizing an 
NMEA 2000 cable, we advise leaving the red and black wires open (please use tape or a suitable 
protective measure to safeguard the header wire). 

The NMEA 0183 input and output of the IS20 are galvanically isolated, in accordance with the NMEA 
standard. Galvanic isolation, also known as opto-isolation, effectively prevents the flow of unwanted 
currents between the instruments and the IS20. This protective feature against potential damage and 
significantly reduces interference with radio signals. 

The NMEA 0183 input of the IS20 supports two different baud rates: 4.8kbps and 38.4kbps. These baud 
rates can be selected from the settings page, allowing you to choose the appropriate data source for the 
IS20. The selected data source provides real-time data to the IS20, which is then displayed on the 
screen for easy monitoring. 

Furthermore, the IS20 has the capability to transmit (repeat) data from the NMEA 0183 input and send it 
to other devices using NMEA 0183 wires. The output baud rate can be configured via the settings page. 
If you wish to forward the data to a computer, you will need a TTL to USB adapter (not included). This 
enables the input data to be displayed on software running on your computer, enhancing data visibility 
and analysis capabilities. 

 

4.2.  Type-C connector 

The IS20 is supplied with a type-C USB connector and USB cable for settings and upgrade its firmware. 
The USB cable can be linked directly to a USB port on the Windows PC.   

4.3.  NMEA 2000 connector 

The IS20 provides a standard male NMEA 2000 connector.   

Data sources provide live data to the system. Apart from NMEA 0183 input port, the IS20 can also be 
connected to a NMEA 2000 network to receive NMEA 2000 data. The NMEA 2000 connector also 
provides the power supply to IS20.   

4.4.  WiFi antenna 

The supplied WiFi antenna needs to be connected to the SMA connector on rear. Connectivity in Station 
Modes on 802.11 b/g/n provides WiFi input of all messages from a server (e.g. a wireless router). This 
WiFi connection can also be disabled by setup into standby mode. 

Connect the antenna by screwing them in clockwise until hand tight. 

 

Summary of Contents for IS20

Page 1: ...ay Night mode for improved visibility Data views include wind speed position depth engine environment fuel and navigation NMEA 0183 NMEA2000 and WiFi network data inputs Efficient power consumption Ve...

Page 2: ...8 4 3 NMEA 2000 connector 8 4 4 WiFi antenna 8 5 Getting Started 9 5 1 Turning the unit on and off 9 5 2 Adjust the brightness 9 5 3 Setup 9 6 Display settings 9 6 1 Data Source 10 6 2 Unit 11 6 3 Dis...

Page 3: ...nd wind data To ensure seamless operation and continued support the IS20 offers firmware updates that can be conveniently maintained by connecting the device to the internet This enables the addition...

Page 4: ...a magnetic compass the IS20 should not be installed within the compass safe distance value listed in the product specifications For example the AS08 needs 0 6 meters minimum distance Airflow to preve...

Page 5: ...e between the case and the mounting holes and cutting the hole too large could compromise the stability of the device after it is mounted Do not use the device as a template when drilling the mounting...

Page 6: ...IS20 Manual V 1 0 6 of 23 2023 Figure 4 Flush mounting cut off drawing 3 Front Panel and buttons Figure 5 IS20 front panel...

Page 7: ...RROW Move down in menu previous favourite page or decrease a numeric value 4 ENTER Select a menu option and to enter the next menu level 5 OK Select menu item or save the setting 4 Connecting the disp...

Page 8: ...rates 4 8kbps and 38 4kbps These baud rates can be selected from the settings page allowing you to choose the appropriate data source for the IS20 The selected data source provides real time data to...

Page 9: ...his page you can conveniently adjust the screen brightness to your desired level ensuring optimal visibility in different lighting conditions 5 3 Setup To access the setup page on the IS20 simply doub...

Page 10: ...nput at a baud rate of 38 4kbps displaying the corresponding data The IS20 is compatible with NMEA 2000 enabling seamless communication with NMEA 2000 sensors and devices when connected to a NMEA 2000...

Page 11: ...Unit menu allows you to specify the preferred units of measure used for data items Currently the following units are supported by the IS20 Depth feet meters or fathom Speed m s knots or km h Temperat...

Page 12: ...French German Greek Italian Norwegian Polish Portuguese Spanish Swedish 6 3 2 Colour scheme The colour scheme and brightness settings allow the display to be set up to be easily visible in most weath...

Page 13: ...nd date setting 6 5 WiFi The IS20 display instrument features WiFi connectivity which allows the display to be connected to and to receive marine navigation data from other devices The IS20 can be set...

Page 14: ...e unique to the IS20 on the network For example if your router s IP address is 192 168 1 1 the IS20 s IP address should be 192 168 1 X where X is a number from 2 to 255 Please ensure this IP address i...

Page 15: ...ng To set up an alarm the data type has to be selected first The current firmware supports the following data types Depth SOG COG heading bearing TWS TWA TWD AWS AWA water temperature water speed ROT...

Page 16: ...quirements For your convenience the whitelist feature allows you to specify and list preferred message types ensuring optimal data handling and management Figure 17 IS20 General Setting Within the gen...

Page 17: ...features and improve the overall customer experience To ensure you have access to the latest advancements the IS20 multifunction display offers firmware update capabilities You can update the firmware...

Page 18: ...e file in hex format to the DFU_APP or similar drive Wait for the copy process to complete which typically takes around 10 to 15 seconds 5 Close the window that displays the drive 6 Turn off the power...

Page 19: ...r a versatile range of styles and formats to ensure the data is presented in a visually appealing and easily understandable manner 7 1 Digital Pages The IS20 offers data display options with support f...

Page 20: ...ehensive and personalized overview of relevant information for enhanced situational awareness 7 3 Rolling road page Figure 20 Rolling road page The rolling road provides waypoint and course deviation...

Page 21: ...ue Heading and Status VDR Set and Drift VHW Water Speed and Heading VLW Dual Ground Water Distance VTG Course Over Ground and Ground Speed VWR Relative Apparent Wind Speed and Angle XDR Battery inform...

Page 22: ...143 4 113 4 54 3 Display size 4 3 diagonal 4 3 Aspect ratio Screen Resolution 800x480 Data input type NMEA 0183 NMEA 2000 WiFi NMEA 2000 load equivalency number LEN 5 Waterproof rating IPx7 Humidity...

Page 23: ...ir distributors or dealers accept responsibility or liability either to the products user or their estate for any accident loss injury or damage whatsoever arising out of the use or of liability to us...

Reviews: