IS20 Manual
V 1.0
16 of 23
2023
Figure 16 Alarm page
This warning message will automatically disappear once the measured data returns to the safety
range. Alternatively, it can be disabled by tapping on the warning window. Additionally, users
have the option to manually disable the warning message by clicking on the warning window
itself, providing flexibility and control over alarm notifications.
6.7. General
You have the flexibility to select the desired baud rate for the output from the available drop-down
menu, catering to various application requirements.
For your convenience, the whitelist feature allows you to specify and list preferred message
types, ensuring optimal data handling and management.
Figure 17 IS20 General Setting
Within the general options of the IS20, users could configure the following settings:
-
NMEA 0183 Output Baud Rate: The IS20 offers a standard NMEA 0183 differential output,
allowing users to repeat the input data and transmit it to other devices such as VHF radios,
autopilots, or computers. The baud rate for this output can be adjusted to align with the
requirements of the connected devices.
-
NMEA 0183 Output Whitelist: The whitelist function enables users to specify the types of
sentences that are permitted for output through the NMEA 0183 interface. By listing the