StorNext QM1200, QS1200 or QS2400 Base System - Replacing a Drive

April 2015

Quantum Corporation

- 1 -

Replacing a Drive in the StorNext QM1200, QS1200 or QS2400 Base 

System

In this procedure, you will replace a failed drive with a new drive.

Before you start to replace a drive in the base system, gather antistatic protection and a replacement drive.

You can determine whether you have a failed drive in two ways: 

The Recovery Guru directs you to replace a failed drive.

You locate the failed drive by checking the amber Service Action Required LEDs in three locations:

Base system 

Drive drawer 

Drive itself 

Locating the Service Action Required LEDs 

Refer to the following sections to locate the service action required LEDs: 

QM1200/QS1200 Drive Tray

 

QS2400 Drive Tray

 

Drive Status LEDs

 

QM1200/QS1200 Drive Tray 

Figure 1

 provides an illustration of the QM1200/QS1200 service action required LED. 

Figure 1  QM1200/QS1200 Service Action Required LED 

1.

Service Action Required LED (Amber)

Summary of Contents for StorNext QM1200

Page 1: ...StorNext QM1200 QS1200 or QS2400 Base System Replacing a Drive 6 67542 02 Rev B 6 67542 02 B...

Page 2: ...tum the Quantum Logo Backup Recovery Archive It s What We Do Be Certain Be Quantum Certain DLT the DLT Logo DLTSage DLTtape the DLTtape Logo DXi DXi Accent Dynamic Powerdown FastSense FlexLink GoProte...

Page 3: ...drive in two ways The Recovery Guru directs you to replace a failed drive You locate the failed drive by checking the amber Service Action Required LEDs in three locations Base system Drive drawer Dr...

Page 4: ...ustration of the QS2400 service action required LED Figure 2 QS2400 service action required LED 1 Service Action Required LED Amber Drive Status LEDs Figure 3 provides an illustration of the drive sta...

Page 5: ...drive on a flat static free surface near the base system b Save all packing materials in case you need to return the drive ATTENTION Possible equipment damage You must replace the drive within three m...

Page 6: ...ED to locate the failed drive Figure 4 and Figure 5 You can also check the Drive Service Action Required LED on the drive Figure 6 Figure 4 QM1200 QS1200 Service Action Required LED 1 Service Action R...

Page 7: ...drive the blue Drive Service Action Allowed LED must be on Figure 6 Item1 7 Remove the failed drive from the base system a Pull the drive handle to the left for a drive in the QM1200 or QS1200 base s...

Page 8: ...to lock the drive securely in place As the drive spins up the Drive Power LED might blink intermittently which indicates that data is being restored to the new drive 2 Check the Drive Power LED and th...

Page 9: ...contact your Customer and Technical Support representative No Go to step 6 6 Remove the antistatic protection 7 Gather support data about your updated storage array by using one of these methods Use t...

Reviews: