Variables and Traps Quick Reference

Table 5

Status Traps

Event

Trap ID

Description

Physical Library Online 
Status Change

101

Issued when the physical library is brought online or 
taken offline.

Physical Library Door 
Status Change

102

Issued when the physical library door has been 
opened, closed, locked, or unlocked.

I/E Station Door Status 
Change

103

Issued when a partition has been brought online or 
taken offline.

RCU Ready

110

Issued when the robotics go from “not ready” to 
“ready” state.

RCU Not Ready

111

Issued when the robotics go from “ready” to “not 
ready” state. Traps 110 and 111 may occur as part of a 
startup or shutdown procedure. If seen at another 
time, it may indicate that the front door is open.

Logical Library Online 
Status Change

204

Issued when a logical library, also known as a 
partition, is brought online or taken offline.

RAS Status Change:
Connectivity

400

Issued when the status of the connectivity subsystem 
changes, which includes the I/O management unit, I/O 
blades, and other components. This may indicate a 
change to “good” status, so check the return value for 
required action. If the return value shows an issue, use 
the LMC to determine the corrective actions.

RAS Status Change: 
Control

401

Issued when the status of the control subsystem 
changes, which includes system firmware, the 
operator panel, and the MCB, RCU, and other control 
blades. If the return value shows an issue, use the 
LMC to determine the corrective actions.

RAS Status Change: 
Cooling

402

Issued when the status of the cooling subsystem 
changes. If the return value shows an issue, use the 
LMC to determine the corrective actions.

RAS Status Change: 
Drives and Media

403

Issued when the status of the drives and/or media 
(including drive brick firmware) changes. If the return 
value shows an issue, use the LMC to determine the 
corrective actions.

RAS Status Change: 
Power

404

Issued when the status of the power subsystem 
changes. If the return value shows an issue, use the 
LMC to determine the corrective actions.

RAS Status Change: 
Robotics

405

Issued when the status of the robotics subsystem 
changes. If the return value shows an issue, use the 
LMC to determine the corrective actions.

Startup Sequence 
Completed

500

Indicates the library startup sequence has completed.

Shutdown Sequence 
Completed

501

Indicates the library shutdown sequence has 
completed.

Summary of Contents for Scalar i2000

Page 1: ...6 01159 03 Scalar i 2000 B a s i c S N M P R e f e r e n c e G u i d e B a s i c S N M P R e f e r e n c e G u i d e Quantum Scalar i2000 Library Quantum Scalar i2000 Library...

Page 2: ...t 2007 by Quantum Corporation All rights reserved Your right to copy this manual is limited by copyright law Making copies or adaptations without prior written authorization of Quantum Corporation is...

Page 3: ...ueries 6 3 Library Identification 7 Product Name 7 Logical Library Name 7 4 Library Status and Health 9 Drive Online Offline Status 9 Drive Overall Health 10 Physical Library Online Offline State 10 R...

Page 4: ...RAS System Status Change Traps 14 Trap 400 connectivityGroupStatusChange 14 Trap 401 controlGroupStatusChange 14 Trap 402 coolingGroupStatusChange 14 Trap 403 drivesAndMediaGroupStatusChange 14 Trap 4...

Page 5: ...ar i2000 MIBs contact technical support This basic SNMP reference is written for library customers partners third party management software developers and other parties interested in integrating the S...

Page 6: ...m support Scalar i2000 User s Guide 6 00421 xx ADIC Management Console User s Guide 6 00064 xx Note Release Notes are also available for this product The Release Notes describe changes to your system...

Page 7: ...cluding answers to frequently asked questions FAQs You can also access software firmware and drivers through this site For further assistance or if training is desired contact Quantum For the most upd...

Page 8: ...4 About This Guide and Your Product...

Page 9: ...on the Scalar i2000 The MIB variables described in this document are the only ones supported by Quantum for external management of the library All other variables in the MIB are for internal use only...

Page 10: ...gather status information about specific components of the library Frequent MIB queries are not required however since the SNMP agent is event driven GETs must also include an instance number This in...

Page 11: ...and it is unique for the entire library Quantum recommends querying the Product Name so that the framework application will list the type of library being monitored Logical Library Name OID 1 3 6 1 4...

Page 12: ...8 Library Identification...

Page 13: ...s variable indicates whether a drive is varied on or varied off Instance There will be one instance for every physical drive in the library Query the specific instance that you need to access Drives a...

Page 14: ...ary Query the specific instance that you need to access Drives are listed in sequential order See Table 1 on the previous page for details on interpreting the format of a drive instance ID Alerted by...

Page 15: ...onDoorStatus Type INTEGER Values open 1 closed 2 closedAndLocked 3 closedAndUnlocked 4 controllerFailed 5 Description The state of the Import Export station door is returned by the phIeStationDoorStat...

Page 16: ...ble provides a concise way to assess the health of the library s subsystems The library functionality is divided into six status groups connectivity control cooling drives and media power and robotics...

Page 17: ...s shutdown sequence which includes reboot and shutdown ADIC Management MIB These informational traps are defined in the ADIC Management MIB Each is issued with enterprise OID management which resolves...

Page 18: ...sChange The state of the connectivity hardware software has changed Trap 401 controlGroupStatusChange The state of the control hardware software has changed Trap 402 coolingGroupStatusChange The state...

Page 19: ...000 Basic SNMP Reference Guide 15 Trap 404 powerGroupStatusChange The state of the power hardware software has changed Trap 405 roboticsGroupStatusChange The state of the robotics hardware software ha...

Page 20: ...16 SNMP Traps...

Page 21: ...of system components with identification and status for each Traps for a changed configuration added and removed components Library startup and shutdown traps ADIC Management MIB The ADIC Management M...

Page 22: ...e Scalar i2000 MIBs reference the following SNMP standard MIBs RFC 1155 SMI RFC 1212 RFC 1213 MIB RFC 1215 These MIBs are necessary for accurate compilation of the Scalar i2000 MIBs and should be incl...

Page 23: ...use the LMC to determine what RAS tickets have been generated for the drive Physical Library Online Offline Status 200 20 80 10 1 5 Indicates if the library is online or offline Use the LMC to confirm...

Page 24: ...turn value for required action If the return value shows an issue use the LMC to determine the corrective actions RAS Status Change Control 401 Issued when the status of the control subsystem changes...

Page 25: ...y identification 7 logical library name 7 product name 7 Library Management Console LMC 5 6 20 library status and health 9 drive online offline status 9 drive overall health 10 I E station door status...

Page 26: ...ed 13 startupSequenceCompleted 13 symbols and notes explained 1 T training contact Quantum 3 Trap 101 13 Trap 102 13 Trap 103 13 Trap 110 13 Trap 111 14 Trap 400 14 Trap 401 14 Trap 402 14 Trap 403 14...

Reviews: