SCSI Description
5–194
Quantum Atlas 10K II Ultra160/m SCSI Hard Disk Drives
RESERVE (10) Command (56h) (continued)
Table 5–92 RESERVE (10) Command — Field Descriptions
Field
Description
3rd Pty
When set to 1, it indicates that the Third Party Device ID field is valid.
LongID
When 0, indicates that the third party device associated with the
reservation release has a number smaller than 255 and the ID value
can be sent within the CDB. If set = 1, indicates that the third party
device ID is greater than 255, the ID value within the CDB is ignored,
and the parameter list length is at least eight.
Third Party Device ID
Required and used only when the 3rdPty bit is set, in which case this
field specifies the SCSI ID of the initiator to be granted the reservation
of the logical unit. The drive preserves the reservation until one of the
following occurs:
• It is superseded by another valid RESERVE command from the
initiator.
• It is released by the same initiator.
• It is released by a TARGET RESET message from any initiator.
• It is released by a hard reset condition.
The drive ignores any attempt to release the reservation made by any
other initiator. For example, if ID7 sends ID2 a Third Party reservation
on behalf of ID6 (the target at ID2 gets reserved for the initiator ID6),
then only ID7 can release the target at ID2 (using a Third Party release).
ID6 cannot release the reservation even though the reservation was
made on its behalf.
Extent
If 0, requests that the entire logical unit be reserved for use only by the
initiator until the request is supplanted by another valid RESERVE
command from the same initiator, or until released via a RELEASE (10)
command from the reserving initiator, a hard reset, or a power on
cycle.
If set = 1, the extent reservation option is implemented. This option
allows an application client in a multitasking environment to have
multiple reservations.
The size of the extent list is defined by the contents of the Parameter
List Length field. The extent list consists of zero or more descriptors.
Each descriptor defines an extent beginning at the specified logical
block address for the specified number of blocks. If the number of
blocks is 0, the extent begins at the specified logical block address and
continues through the last logical block address on the logical unit.
The data format of extent descriptors is shown in Figure 5-91.
Summary of Contents for Quantum Atlas 10K II 9.2/18.4/36.7/73.4 GB
Page 15: ...Contents Quantum Atlas 10K II Ultra 160 m SCSI Hard Disk Drives xv...
Page 19: ...Contents Quantum Atlas 10K II Ultra 160 m SCSI Hard Disk Drives xix...
Page 25: ...About This Manual 1 4 Quantum Atlas 10K II Ultra 160 m SCSI Hard Disk Drives...
Page 55: ...Installation 3 28 Quantum Atlas 10K II Ultra 160 m SCSI Hard Disk Drives...
Page 69: ...SCSI Description 5 2 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 79: ...SCSI Description 5 12 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 81: ...SCSI Description 5 14 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 83: ...SCSI Description 5 16 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 87: ...SCSI Description 5 20 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 89: ...SCSI Description 5 22 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 99: ...SCSI Description 5 32 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 119: ...SCSI Description 5 52 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 125: ...SCSI Description 5 58 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 203: ...SCSI Description 5 136 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 205: ...SCSI Description 5 138 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 213: ...SCSI Description 5 146 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 217: ...SCSI Description 5 150 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 221: ...SCSI Description 5 154 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 231: ...SCSI Description 5 164 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 265: ...SCSI Description 5 198 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 267: ...SCSI Description 5 200 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 269: ...SCSI Description 5 202 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 275: ...SCSI Description 5 208 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 277: ...SCSI Description 5 210 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 279: ...SCSI Description 5 212 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 281: ...SCSI Description 5 214 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 283: ...SCSI Description 5 216 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 285: ...SCSI Description 5 218 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 291: ...SCSI Description 5 224 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 293: ...SCSI Description 5 226 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 295: ...SCSI Description 5 228 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 297: ...SCSI Description 5 230 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 315: ...Feature Descriptions 6 14 Quantum Atlas 10K II Ultra 160 m SCSI Hard Disk Drives...
Page 321: ...Appendix A Quick Reference A 6 Quantum Atlas 10K II Ultra 160 m SCSI Hard Disk Drives...
Page 363: ...Appendix B SCSI Bus Signal Timing B 42 Quantum Atlas 10K II Ultra 160 m SCSI Hard Disk Drives...
Page 369: ...Index I 4 Quantum Atlas 10K II Ultra 160 m SCSI Hard Disk Drives...
Page 370: ......
Page 371: ...500 McCarthy Blvd Milpitas CA 95035 408 894 4000 www quantum com June 8 2000 81 122517 04...