SCSI Description
5–90
Quantum Atlas 10K II Ultra160/m SCSI Hard Disk Drives
MODE SELECT (6) Command (15h) (continued)
Table 5–42 Codes Used by the MRIE Field
Field
Description
0h
No reporting of informational exception condition. This method instructs the disk drive
not to report these conditions.
1h
Asynchronous Event Reporting. This method of reporting instructs the disk drive to
report informational exception conditions by using the rules for asynchronous event
reporting as described in the SCSI-3 Architecture Model and the relevant Protocol
Standard. The sense key will be set to RECOVERED ERROR and the additional sense
code will indicate the cause of the informational exception condition.
2h
Generate Unit Attention. This method of reporting instructs the disk drive to report
informational exception conditions by returning a CHECK CONDITION status on any
command. The sense key is set to UNIT ATTENTION and the additional sense code will
indicate the cause of the information exception condition. The command that has the
CHECK CONDITION will not be executed before the informational exception condition
is reported.
3h
Conditionally Generate Recovered Error. This method of reporting instructs the disk
drive to report informational exception conditions dependent on the value of the PER
bit of the Error Recovery Paramaters Mode Page, by returning a CHECK CONDITION
status on any command. The sense key will be set to RECOVERED ERROR and the
additional sense code will indicate the cause of the informational exception condition.
The command that has the CHECK CONDITION will complete before and informational
exception condition is reported.
4h
Unconditionally Generate Recovered Error. This method of reporting instructs the disk
drive to report informational exception conditions regardless of the value of the PER bit
of the Error Recovery Parameters Mode Page, by returning a CHECK CONDITION status
on any command. The sense key will be set to RECOVERED ERROR and the additional
sense code will indicate the cause of the informational exception condition. The
command that has the CHECK CONDITION will complete without error before any
informational exception condition will be reported.
5h
Generate No Sense. This method of reporting instructs the disk drive to report
informational exception conditions by returning a CHECK CONDITION status on any
command. The sense key will be set to NO SENSE and the additional sense code will
indicate the cause of the informational exception condition. The command that has
the CHECK CONDITION will complete without error before any informational exception
condition is reported.
6h
Only Report Informational Exception Condition On Request. This method of reporting
instructs the disk drive to preserve the informational exception(s) data. To learn about
these exception conditions, the application client polls the disk drive via an unsolicited
REQUEST SENSE command. The sense key is set to NO SENSE and the additional sense
code will indicate the cause of the informational exception condition.
7h – Bh
Reserved.
Ch – Fh
Vendor-specific.
Summary of Contents for Quantum Atlas 10K II 9.2/18.4/36.7/73.4 GB
Page 15: ...Contents Quantum Atlas 10K II Ultra 160 m SCSI Hard Disk Drives xv...
Page 19: ...Contents Quantum Atlas 10K II Ultra 160 m SCSI Hard Disk Drives xix...
Page 25: ...About This Manual 1 4 Quantum Atlas 10K II Ultra 160 m SCSI Hard Disk Drives...
Page 55: ...Installation 3 28 Quantum Atlas 10K II Ultra 160 m SCSI Hard Disk Drives...
Page 69: ...SCSI Description 5 2 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 79: ...SCSI Description 5 12 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 81: ...SCSI Description 5 14 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 83: ...SCSI Description 5 16 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 87: ...SCSI Description 5 20 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 89: ...SCSI Description 5 22 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 99: ...SCSI Description 5 32 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 119: ...SCSI Description 5 52 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 125: ...SCSI Description 5 58 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 203: ...SCSI Description 5 136 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 205: ...SCSI Description 5 138 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 213: ...SCSI Description 5 146 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 217: ...SCSI Description 5 150 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 221: ...SCSI Description 5 154 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 231: ...SCSI Description 5 164 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 265: ...SCSI Description 5 198 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 267: ...SCSI Description 5 200 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 269: ...SCSI Description 5 202 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 275: ...SCSI Description 5 208 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 277: ...SCSI Description 5 210 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 279: ...SCSI Description 5 212 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 281: ...SCSI Description 5 214 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 283: ...SCSI Description 5 216 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 285: ...SCSI Description 5 218 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 291: ...SCSI Description 5 224 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 293: ...SCSI Description 5 226 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 295: ...SCSI Description 5 228 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 297: ...SCSI Description 5 230 Quantum Atlas 10K II Ultra160 m SCSI Hard Disk Drives...
Page 315: ...Feature Descriptions 6 14 Quantum Atlas 10K II Ultra 160 m SCSI Hard Disk Drives...
Page 321: ...Appendix A Quick Reference A 6 Quantum Atlas 10K II Ultra 160 m SCSI Hard Disk Drives...
Page 363: ...Appendix B SCSI Bus Signal Timing B 42 Quantum Atlas 10K II Ultra 160 m SCSI Hard Disk Drives...
Page 369: ...Index I 4 Quantum Atlas 10K II Ultra 160 m SCSI Hard Disk Drives...
Page 370: ......
Page 371: ...500 McCarthy Blvd Milpitas CA 95035 408 894 4000 www quantum com June 8 2000 81 122517 04...