Installing the Internal LTO-3 Half-Height Tape Drive

LTO-3 Half-Height Tape Drive Quick Start Guide

Figure 3  Internal Parallel SCSI 
Bus Termination Examples

 

    

After configuring the parallel SCSI ID and bus termination power, proceed to 

Mounting 

the Internal Tape Drive

 in the following subsection.

Mounting the Internal 
Tape Drive

0

You can mount the internal LTO-3 Half-Height Tape Drive either horizontally or 

vertically, but not upside down (see 

figure 4

). 

Figure 4  Acceptable Mounting 
Orientations

Note:

The internal parallel SCSI LTO-3 Half-Height Tape Drive does not provide 

SCSI termination. The last device at the end of the parallel SCSI bus chain must 

have a SCSI bus terminator.

IF you mount the drive . . . 

THEN the . . . 

horizontally,

base of the drive must be within 15 degrees of 
horizontal.

vertically,

side of the drive must be within 5 degrees of 
horizontal.

Tape drive

 

(no termination)

SCSI device

 

(termination 
disabled)

SCSI controller

 

(termination 
enabled)

SCSI device 

 

(termination enabled)

Tape drive

 

(no termination)

SCSI controller

 

(termination enabled)

SCSI terminator

SCSI terminator

            YES                                YES                               YES                                                 NO

     

Summary of Contents for LTO3 A-Series

Page 1: ...ta transfer rate and Dynamic Powerdown to protect the drive and media in the event of power loss Combined with SmartVerify to concurrently verify all data written to the tape these features make Quant...

Page 2: ...ot remove the wrist strap until you finish working with the drive Also avoid contact between the drive other equipment and clothing The wrist strap only protects the equipment from ESD voltages on the...

Page 3: ...nspected and carefully packaged at the factory damage can occur in shipment or when the drive is being unpacked Observe the handling precautions in Handling Precautions and Installation Guidelines and...

Page 4: ...ce on the parallel SCSI bus must have its own unique SCSI ID Use SCSI configuration jumper pins 1 2 3 4 5 6 and 7 8 on the drive back panel to change the SCSI ID of the LTO 3 Half Height Tape Drive se...

Page 5: ...of the parallel SCSI bus must have either A parallel SCSI bus terminator Terminator power enabled See figure 3 for examples of internal parallel SCSI bus termination To disable terminator power remove...

Page 6: ...figure 4 Figure 4 Acceptable Mounting Orientations Note The internal parallel SCSI LTO 3 Half Height Tape Drive does not provide SCSI termination The last device at the end of the parallel SCSI bus c...

Page 7: ...Position the drive in the bay and align either the upper or lower mounting holes whichever is appropriate with the holes in the chassis see figure 5 5 Secure the drive using two M3 0 X 4 metric screws...

Page 8: ...internal drive as follows 1 Verify that the system is shut down and the AC power cord is disconnected from the facility AC power receptacle 2 Depending on the interface configuration of your internal...

Page 9: ...and DC power cables proceed to Restarting the Internal Tape Drive System in the following subsection Restarting the Internal Tape Drive System 0 After connecting the internal drive interface and DC po...

Page 10: ...button SCSI ID selector switch on the drive back panel to change the SCSI ID of the tabletop LTO 3 Half Height Tape Drive see figure 8 Figure 8 Tabletop Parallel SCSI ID Selector Switch IF the default...

Page 11: ...llel SCSI drive either SCSI connector can be used as a SCSI IN or SCSI OUT connection This means you can use either connector to attach the drive to a host computer or to another parallel SCSI device...

Page 12: ...or on the back of the drive Figure 11 Tabletop Parallel SCSI Bus Termination Examples 3 Verify that the tabletop LTO 3 Half Height Tape Drive AC power switch is set to the off position and connect the...

Page 13: ...TO Driver Software Registering the LTO 3 Half Height Tape Drive Installing the LTO Driver Software If you intend to use the LTO 3 Half Height Tape Drive with the Microsoft native backup applet on a Wi...

Page 14: ...tions IECEE International Electrotechnical Commission on Electrical Equipment IECEE for Mutual Recognition of Test Certificates for Electrical Equipment CB Scheme CB Scheme per IEC 60950 1 with detail...

Page 15: ...Emissions per CISPR 22 EN55022 and Immunity per CISPR 24 EN55024 Israel SII CISPR 22 and CISPR 24 Japan Voluntary Control Council for Interface VCCI VCCI New Zealand Australian Communications and Medi...

Page 16: ...101 UK France and Germany 00800 4 QUANTUM EMEA 44 1256 848 766 For worldwide support www quantum com contactsupport 81 81713 02 A01 May 2007 LTO 3 Half Height Tape Drive Quick Start Guide Backup Recov...

Reviews: