ELM & ELM2 EMERGENCY LIGHTING UNIT RECALL INSPECTION & CIRCUIT BOARD REPLACEMENT INSTRUCTIONS | 6
5TH STEP:
REQUESTING A NEW CIRCUIT BOARD:
After determining the total number of recalled
circuit boards, then order free replacement boards
by going to www.lithonia.com and clicking on
“Quantum
®
ELM/ELM2 Recall Information” at the
bottom of the page, or call 888.615.4501.
If any circuit boards are missing one or both of the
rectangular chips in the upper right corner, call the
recall toll-free number at 888.615.4501 rather than
placing your order on-line.
When the replacement boards arrive, proceed to
the 6th step.
A
Recall toll-free number:
888.615.4501
www.lithonia.com
CAUTION:
BEFORE PROCEEDING WITH THESE STEPS, TURN OFF ELECTRICITY AT
FUSE OR CIRCUIT BREAKER LOCATION. READ AND FOLLOW
IMPORTANT
SAFEGUARDS
ON FRONT COVER SHEET.
6TH STEP: REMOVING AND REPLACING RECALLED CIRCUIT BOARD ONCE
REPLACEMENT BOARD HAS BEEN RECEIVED:
Remove the affected emergency lighting units
from the wall. Refer to your previously used
inventory list for all affected units.
Dismount all of the affected units:
A
Note: If your light unit is included in the recall, and you have ordered and received a replacement
circuit board, follow these step-by-step removal and replacement instructions.
ELM2 units only: Disconnect the two blue
and yellow wire lamp connectors (they are
black clasps). The connectors are released by
pressing on the connector lock as shown and
gently pulling the connector apart.
ELM units only: These units do NOT have the
black connectors, so you will not perform this
step yet. Proceed to the step 6D.
Disconnect the lamp connectors
(Blue and Yellow wire harnesses):
C
Disconnect the single pole connector (red
battery wire) to disconnect battery power.
B
Disconnect the red battery wire connector: