background image

DXi6700, DXi6701, and DXi6702 Specifications

17

DXi6700/DXi6701/DXi6702

Table 6  Cable Drops

Table 7  Virtual Device Limits 
and Hardware Interfaces

DXi6700, DXi6701, and DXi6702 Cable Drops

Ethernet Cable Drops

DXi6700 (2 x 1 GbE ports) - 

1 to 2 1 GbE Ethernet connections for NAS or 

OST connectivity, replication, and remote management

DXi6701 (6 x 1 GbE ports) -

 1 to 6 1 GbE Ethernet connections for NAS or 

OST connectivity, replication, and remote management

DXi6702 (2 x 1 GbE ports and 2 x 10 GbE ports) -

 1 to 2 1 GbE Ethernet 

connections and 1 to 2 10 GbE Ethernet connections (optical or Twinax) for 

NAS or OST connectivity, replication, and remote management

Note:

The 10 GbE Copper (Twinax) cable options that Quantum provides 

do not support all switches. Please note the supported switches 

during the purchase-configuration process, and if the Twinax cables 

supplied by Quantum are 

not

 compatible with your switch, then you 

will need to provide your own compatible Twinax cables from your 

switch vendor. Be sure to have these available before the system 

installation takes place.

Fibre Channel Drops

1 to 4 Fibre Channel connections for data transfer and path-to-tape 

connections

Power Outlets

Node

 - 2 USA type 3-prong power outlets (

Nema 5-15

) or 2 C13 type 

3-prong power outlets (

IEC320 C13

). For additional information, see 

Table 8

.

Expansion Module (each)

 - 2 USA type 3-prong power outlets (

Nema 

5-15

) or 2 C13 type 3-prong power outlets (

IEC320 C13

).

USA type 3-prong power outlet (Nema 5-15)

 

C13 type 3-prong power outlet (IEC320 C13

)

DXi6700, DXi6701, and DXi6702 Virtual Device Limits and Hardware Interfaces

Virtual Device Limits

VTL backup target:

 64 partitions maximum

NAS backup target:

 128 shares maximum (NFS or CIFS)

OST backup target:

 100 storage servers maximum

Note:

Samba version: 3.5.2

Summary of Contents for DXi6700 series

Page 1: ...xible easy to use interface options including NAS OST virtual library or mixed presentations as well as Ethernet and Fibre Channel connectivity DXi6700 appliances are part of a comprehensive set of ba...

Page 2: ...on all DXi6700 models Note DXi6700 DXi6701 and DXi6702 support NDMP V4 Data Deduplication Enables the data deduplication capability License key is pre installed on all DXi6700 models Replication Enab...

Page 3: ...stallation be sure to consider leaving room in the rack for future system expansion You can expand the storage capacity of the DXi6700 by adding up to nine expansion modules Also be sure to leave adeq...

Page 4: ...more complex to set up and may require switch configuration changes Use the Custom network option only if it is required by your network Note The Custom network option requires one or more sets of net...

Page 5: ...ts throughout the server and storage ecosystem Possible negative effects of improper configuration range from sub optimal performance to silent network problems that are hard to diagnose In general th...

Page 6: ...t has no effect on data reception inbound to the DXi system Inbound traffic is controlled by the load balancing algorithm within the upstream Ethernet switch Based on the switch algorithm in use traff...

Page 7: ...r switch and configure IP information appropriately on the Network page Intermediate Network Recommendations Intermediate network configurations do not include segmentation but do require switch re co...

Page 8: ...rse port ETH0 and Management and Data traffic will exclusively traverse ETH1 DXi6700 2 x 1 GbE Ports and DXi6701 6 x 1 GbE Ports For advanced network configuration follow these steps 1 For Segmentatio...

Page 9: ...Replication Firewall Port Requirements The following firewall ports must be opened for replication to operate Port 80 Port 1062 Installation and Integration Services Installation and integration of t...

Page 10: ...tum sales representative Service Package Upgrades Quantum s Global Services organization is geared towards delivering the fastest possible response and root cause resolution helping you maximize your...

Page 11: ...ical components in the environment Faster Resolution Time When issues occur StorageCare Guardian provides better diagnostics data that will enable Quantum to identify the root cause for rapid problem...

Page 12: ...1 48 TB 5 48 TB 3 1 56 TB 6 56 TB 2 2 To upgrade the capacity of a DXi6700 to 64 TB or greater the DXi must be converted to a DXi6701 or DXi6702 first For more information about model conversion see...

Page 13: ...ports 2 x 10 GbE Ethernet ports optical or Twinax 4 x 8 Gb Fibre Channel ports 8 TB 3U for node 2U for each expansion module 16 TB 1 24 TB 2 24 TB 1 32 TB 3 32 TB 1 1 40 TB 4 40 TB 2 48 TB 5 48 TB 1 2...

Page 14: ...Dimensions Total Pallet Weight 1 0 Width 43 in 109 2 cm Length 28 in 71 2 cm Height 16 in 40 6 cm Approximately 125 lbs 56 7 kg 1 1 Width 43 in 109 2 cm Length 28 in 71 2 cm Height 26 in 66 0 cm Appr...

Page 15: ...8 Width 52 in 132 1 cm Length 42 in 106 7 cm Height 56 in 91 4 cm Approximately 810 lbs 367 4 kg 1 9 Width 52 in 132 1 cm Length 42 in 106 7 cm Height 56 in 116 8 cm Approximately 885 lbs 401 4 kg Num...

Page 16: ...system components Table 4 Physical Characteristics Table 5 Storage Capacity Table 6 Cable Drops Table 7 Virtual Device Limits and Hardware Interfaces Table 8 Power Requirements Table 4 Physical Chara...

Page 17: ...g the purchase configuration process and if the Twinax cables supplied by Quantum are not compatible with your switch then you will need to provide your own compatible Twinax cables from your switch v...

Page 18: ...45 connector and 4 ports 8 Gb Fibre Channel LC connector DXi6701 6 ports 100 1000BASE T Ethernet RJ45 connector and 4 ports 8 Gb Fibre Channel LC connector DXi6702 2 ports 10 100 1000BASE T Ethernet R...

Page 19: ...ords with IEC320 C13 to Nema 5 15 connectors Two 2 C13 to C14 type 3 prong power cords with IEC320 C13 to IEC320 C14 connectors Expansion Module Two 2 hot swappable redundant power supplies Two 2 USA...

Page 20: ...Xi6702 to an uninterruptable power supply UPS with a minimum UPS capacity rating that meets the power requirements stated above Average AC Current Node 570 Watts 5 7A 100 VAC 1945 BTU hr 570 Watts 2 4...

Page 21: ...pping and storage 30m to 12 000 m 100 to 39 370 ft Vibration and Shock Operational Shock Peak Acceleration 3G Duration 8 milliseconds Wave Shape Sine Operational Vibration Mode Swept frequency Frequen...

Page 22: ...As a long standing and trusted partner the company works closely with a broad network of resellers OEMs and other suppliers to meet customers evolving data protection needs 6 67200 01 B 22 6 67200 01...

Reviews: