SCSI Commands
5-100
Quantum DLT 7000 Tape System
MODE SELECT (6) / (10) Command (15h) / (55h) (continued)
5.9.10
Changeable Parameters within MODE SELECT
The table below lists the MODE SELECT command’s changeable parameters
and their default, minimum, and maximum values. Descriptions of the various
parameters are provided in the discussions of the different mode pages within
MODE SELECT. Note that parameter rounding is supported for all parameters
except for the block descriptor length.
Table 5–48 Changeable Mode Parameters within MODE SELECT
Page: Parameter
Default
Minimum
Maximum
Header: Buffered Mode, Device Specific Byte
1
0
1
Block Descriptor Length
08h
00h
08h
Block Descriptor: Block Length
2.0 GB and 6.0 GB Mode
10.0 GB and 20.0 GB Mode
35.0 GB and 70 GB Mode
0
0
0
0
0
0
40000h
FFFFFEh
FFFFFEh
READ / WRITE Error Recovery (01h): PER bit
0
0
1
Control Mode (0Ah): RLEC
0
0
1
Data Compression (0Fh): DCE
1
0
1
Disconnect / Reconnect (02h): Maximum Burst Size
0080h
0000h
FFFFh
Disconnect / Reconnect (02h): DTDC
0
0
3
Device Configuration (10h): WRITE Delay Time
C8h
Fh
1964h
Device Configuration (10h): SEW
1
0
1
Device Configuration (10h): Select Data Compression
Algorithm
1
0
1
Summary of Contents for 7000DLT Series
Page 1: ...DLT 7000 Tape System Product Manual November 10 2003 81 60000 06...
Page 5: ...USER MANUAL STATEMENTS FOR CLASS B EQUIPMENT continued...
Page 6: ......
Page 38: ...General Description and Specifications 1 14 Quantum DLT 7000 Tape System...
Page 292: ...Appendix C Updating the Firmware C 6 Quantum DLT 7000 Tape System...
Page 310: ...Index Index 6 Quantum DLT 7000 Tape Drive...
Page 311: ......