SCSI Commands
5-36
Quantum DLT 7000 Tape System
LOG SELECT Command (4Ch) (continued)
Bit
Byte
7
6
5
4
3
2
1
0
0 -1
(MSB)
Parameter Code
(LSB)
2
DU
DS
TSD
ETC
TMC
Rsv’d
LP
3
Parameter Length
4 - 7
(MSB)
Parameter Value
(LSB)
NOTE:
Byte 2 is also referred to the Parameter Control Byte.
Figure 5–15 LOG SELECT Log Parameters Format
Table 5–18 LOG SELECT Log Parameters Field Descriptions
Field Name
Description
Parameter Code
Parameter Codes supported for the READ/WRITE error counter pages are as
follows:
Parameter Code
- Descriptions
00h - Errors corrected with substantial delays
01h - Errors corrected with possible delays
02h - Total rewrites or rereads
03h - Total errors corrected
04h - Total times correction algorithm processed
05h - Total bytes processed
06h - Total uncorrected errors
8000h - Vendor Unique