SCSI Commands
Quantum DLT 7000 Tape System
5-79
MODE SELECT (6) / (10) Command (15h) / (55h) (continued)
Table 5–42 Control Mode Page Descriptor - Field Descriptions
Field Name
Description
PS
Parameters Savable. For MODE SELECT, this bit must be 0.
Page Length
The Page Length field indicates the number of bytes in the Control Mode
Page that follow this byte. The valid value for this byte is 06h.
RLEC
Report Log Exception Condition. When set to 1, specifies that the target
will report log exception conditions. When 0, specifies that the target
will not report log exception conditions.
The RLEC bit works in conjunction with the READ / WRITE Error Log
Sense Page, specifically, the TMC bit of the READ / WRITE Error Log
SENSE Page (Page 2 and 3), described earlier in this manual.
The RLEC bit indicates whether the drive should return CHECK
CONDITION status with sense key set to UNIT ATTENTION when one of
the READ and WRITE error counters of the log pages reach a specified
threshold. Thresholds can be modified using LOG SELECT.
Queue Algorithm
Modifier
Must be 0.
Qerr
Queue Error. Must be 0.
DQue
Disable Queuing. Must be 0.
EECA
Enable Extended Contingent Allegiance. Not supported; must be 0.
RAENP
Ready Asynchronous Event Notification. Not supported; must be 0.
UAAENP
Unit Attention Asynchronous Event Notification. Not supported; must be
0.
EAENP
Enable AEN Permission. Asynchronous event notification is not
supported; must be 0.
Ready AEN Holdoff
Period
Not supported; must be 0.
Summary of Contents for 7000DLT Series
Page 1: ...DLT 7000 Tape System Product Manual November 10 2003 81 60000 06...
Page 5: ...USER MANUAL STATEMENTS FOR CLASS B EQUIPMENT continued...
Page 6: ......
Page 38: ...General Description and Specifications 1 14 Quantum DLT 7000 Tape System...
Page 292: ...Appendix C Updating the Firmware C 6 Quantum DLT 7000 Tape System...
Page 310: ...Index Index 6 Quantum DLT 7000 Tape Drive...
Page 311: ......