UANTA COMPUTER INC.
Layer 2/3/4 Managed Switch
_____________________________________________________________________________
LB9
User’s Guide 963/1523
10.5.2
show dcbx priority-flow-control interface
This command displays DCBX priority flow control paramters for an interface.
Syntax
show dcbx priority-flow-control interface <slot/port>
<slot/port>
-
interface number
Default Setting
None
Command Mode
Privileged Exec
Display Message
Port:
Displays the interface number.
Show Type:
Displays the data type, including Admin Config, Oper Config, and Peer Config.
Feature:
Displays the feature name.
Enable:
Displays the enable mode of PFC
Advertise:
Display the advertise mode of PFC
Willing:
Display the willing mode of PFC
Priority Mask:
Display the priority mask of PFC, priority is shown from 0 to 7 in sequence. 0 means
the priority is disabled, and 1 means the priority is enabled.
Max Traffic Class:
Displays the max. traffic class support.
Oper Version:
Displays the operational version of PFC feature.
Max Version:
Displays the maximum version of PFC feature.
Error:
Displays the error code
Operational Mode:
Displays the operational mode of PFC feature.
Syncd with Peer:
Displays if feature is synchronized with peer.
(Quanta) #show dcbx priority-flow-control interface 0/1
Port........................................... 0/1
Show Type...................................... Admin Config
Feature........................................ Priority Flow Control
Enable......................................... true