UANTA COMPUTER INC.
Layer 2/3/4 Managed Switch
_____________________________________________________________________________
LB9
User’s Guide 1090/1523
sFlow Receiver Maximum Datagram Size
- The maximum number of data bytes that can be sent
in a single sample datagram.
sFlow Receiver Address
- The IP address of the sFlow collector.
sFlow Receiver Port
- The destination port for sFlow datagrams.
sFlow Receiver Datagram Version
- The version of sFlow datagrams that should be sent.
Command Buttons
Submit
- Send the updated data to the switch and cause the changes to take effect on the switch.
Refresh
- Refresh the data on the screen with present state of data in the switch.
11.2.14.3
Configuring sFlow Poller Configuration Page
sFlow agent collects time-based sampling of network interface statistics and sends them to the
configured sFlow receivers. A data source configured to collect counter samples is called a poller.
Selection Criteria
Poller Datasource(Slot/Port)
- sFlowDataSource for this sFlow sampler. This Agent will support
Physical ports only.
Configurable Data
Receiver Index
- The sFlowReceiver associated with this counter poller. Allowed range is (1 to 8 )
Poller Interval
- The maximum number of seconds between successive samples of the counters
associated with this data source. A sampling interval of 0 disables counter sampling. Allowed range
is (0 to 86400 secs)
Non-Configurable Data
Poller DataSource
- The interface for which data is being displayed.
Receiver Index
- The sFlowReceiver for this sFlow Counter Poller. If set to 0, the poller
configuration is set to default and the poller is deleted. Only active receivers can be set. If a receiver
expires then all pollers associated with the receiver will also expire. Allowed range is (1 to 8 )
Poller Interval
- The maximum number of seconds between successive samples of the counters
associated with this data source.
Command Buttons
Submit
- Send the updated data to the switch and cause the changes to take effect on the switch.
Refresh
- Refresh the data on the screen with present state of data in the switch.