SANTA FE FREESTANDING
Termination Cap
Hose Clamp
Trim Ring
Flex Hose
Collar
Assembly
6
Appliance Set-Up
A. Outside Air Kit Instructions
Parts Included in Kit:
1 piece of 2 inch x 3 foot flex hose,
2 hose clamps, 1 air intake channel1 collar assembly, 1
termination cap assembly, 1 trim ring, 12 screws. (Discard
air channel it is not need for this appliance).
Tools Needed:
Phillips head screwdriver; wire cutters; hole
saw or jig saw.
1.
Measure distance from floor to air vent opening in
appliance and mark location on wall.
Use saw to cut opening in wall. Cut a 2-1/2 to 3 inch
(64-76mm) opening on inside wall and a 3 to 3-1/2 inch
(76-89mm) opening on outside of house.
2. Remove cover plate and then install the collar
assembly.
3.
Use hose clamp to secure flex pipe to collar assembly.
4.
Slide trim ring over flex pipe and run pipe through wall.
5. Attach hose to outside termination cap with second
hose clamp.
6. Secure termination cap to outside surface.
7. Secure trim ring to interior wall.
CAUTION
Never draw outside combustion air from:
•
Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage
Flex Hose
Hose Clamp
Collar Assembly
Trim Ring
Termination
Cap Assembly
Hose Clamp
Air Intake Channel
(Discard)
Figure 20.2
Figure 20.1