18
7050-145L
August 3, 2018
SANTA FE FREESTANDING
C. Through The Wall & Vertical - Exterior
Figure 18.1
Figure 18.2
D. Vertical - Interior - Typical Installation
Figure 18.3
Firestop
Flashing
Rain Cap
6 in.
(152mm)
Min.
Non-combustible Hearth Pad
3 in. (76mm)
Min.
12 in.
(305mm)
Minimum
3 in. to 3 in.
(76-76mm)
Top Vent Kit
Clean-out Cover
on other side
Non-combustible Hearth Pad
Clean-out Cover
Tee
Wall Thimble
Support
Bracket
every 60 in.
(1.5m)
12 in.
(305mm)
Minimum
Rain Cap
Flashing
2 in. (51mm) minimum
6 in. (152mm)
Minimum
Firestop
Flashing
Rain Cap
6 in.
(152mm)
Minimum.
Non-combustible Hearth Pad
3 in. (76mm)
Minimum.
Cleanout Cover
12 in. (305mm)
Minimum
Ceiling Support
6 in. (152mm) Flue
Connector
6 in. (152mm) Class A
Chimney Connector
Adapter
3 in. to 6 in.
(76-152mm)
Top Vent Kit
All three installations are approved for mobile home
installations. Must use 3 or 4 inch (76 to 102mm) “L” or
“PL” Listed pellet venting or Listed double wall pipe and
Quadra-Fire Outside Air Kit in mobile homes. Single wall
pipe is approved for residential installations only.
*NOTE:
Clearance to combustibles are for standard pellet
pipe. If pellet pipe manufacturer allows reduced
clearances to their pipe, reduced clearances are
allowed.
B. Vertical into Existing Class A Chimney
NOTE:
A chimney connector shall not pass through an attic
or roof space, closet or similar concealed space, or a
floor or ceiling.