Page 10
7036-135E
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
E. Minimum Opening for Masonry and Zero
Clearance Fireplaces
Location
Inches
Millimeters
A
Insert side to combustible side wall
6
152
B
Insert top to max. 2-1/4 inch face trim
0
0
C
Insert side to max. 2-1/4 inch face trim
0
0
Location
Inches
Millimeters
F
Rear Width
24
610
G
Depth
15
381
H
Height
23-7/8
606
I
Front Width
34
864
Figure 10.2
Figure 10.3
C. Masonry and Zero Clearance Fireplaces
Location
Inches
Millimeters
D
Floor protection hearth extension from
door opening
6
152
E
Floor protection to the side of door
opening
6
152
D. Floor Protection
F
G
H
I
F. Mantel Projections
J
K
Mantel
Face
Trim
D
E
A
C
B
Side
W
a
ll
Figure 10.4
Built-In Vertical
Figure 10.1
se two
degree elbows to
clear heat shield and hopper
in
mm
in
mm
in
mm
The maximum mantel depth
(J)
is 12 inches (305mm) with
a minimum vertical height
(K)
of 12 inches (305mm).
However if your mantel has a depth of 10 inches (254mm)
then the vertical minimum height is 10 inches (254mm).