Mt. Vernon Pellet Insert (AE)
5
Venting Systems
Figure 15.2
A.
D
irect Connect Without Outside Air
B.
D
irect Connect With Outside Air
NOTE:
In Canada, where passage through a wall or partition of
combustible construction is desired, the installation shall
conform to CAN/CSA-B365.
Outside Air
through
Rear Wall
Figure 15.1
Fire Risk.
Inspection of Chimney:
• Masonry chimney must be in good condition.
• Meets minimum standard of NFPA 211
• Factory-built chimney must be 6 inch (152mm)
UL103 HT.
WARNING
CAUTION
Never draw outside combustion air from:
• Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage
NOTE:
•
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
•
Illustrations/diagrams are not drawn to scale.
•
Actual installation may vary due to individual design
preference.
NOTE;
Use metal plate
around exhaust vent pipe
and seal all edges with
non-flammable insulation
such as fiberglass, mineral
wool or ceramic material.
Do not use high tempera-
ture caulking materials to
seal any edge to prevent
future serviceability.