Explorer III Wood Stove

CAUTION

THE STRUCTURAL INTEGRITY OF THE MOBILE HOME 

FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED
Do NOT cut through:

•  Floor joist, wall, studs or ceiling trusses.

•  Any supporting material that would affect the structural integ-

rity.

Asphyxiation Risk

NEVER INSTALL IN A SLEEPING ROOM.
Consumes oxygen in the room.

WARNING

You must use a Quadra-Fire Outside Air Kit Part 

OAK-ACC for installation in a mobile home.

1.  An outside air inlet must be provided for combustion.
2.  Appliance must be secured to the mobile home structure 

by bolting the legs to the floor.  

3. Appliance must be grounded with #8 solid copper 

grounding wire or equivalent and terminated at each end 

with N.E.C. approved grounding device.

4.  Appliance must be installed with an approved UL103 HT 

ventilated  chimney  connector,  UL103  HT  chimney,  and 

terminal cap with spark arrestor.  Never use a single wall 

connector (appliance pipe) in a mobile home installation.  

Use  only  double-wall  connector  pipe,  Dura-Vent  DVL, 

Selkirk  Metalbestos  DS  or  Security  DL  double-wall 

connector or any listed double-wall connector pipe.

5.  In Canada, this appliance must be connected to a 6 inch 

(152mm)  factory-built  chimney  conforming  to  CAN/ULC-

629M, STANDARD FOR FACTORY BUILT CHIMNEYS. 

6.  Follow the chimney and chimney connector manufacturer’s 

instructions when installing the flue system for use in a 

mobile home.

7.  Maintain clearance to combustibles.
8.  Floor protection requirements must be followed precisely.
9.  Use  silicone  to  create  an  effective  vapor  barrier  at  the 

location where the chimney or other component penetrates 

to the exterior of the structure.

NOTE:

    Offsets  from  the  vertical,  not  exceeding  45°,  are 

allowed per Section 905(a) of the Uniform Mechanical Code 

(UMC). Offsets greater than 45° are considered horizontal and 

are also allowed, providing the horizontal run does not exceed 

75% of the vertical height of the vent. Construction, clearance 

and termination must be in compliance with the UMC Table 

9C. This installation must also comply with NFPA 211.

NOTE:

 Top sections of chimney must be removable to allow 

maximum clearance of 13.5 feet (411cm) from ground level 

for transportation purposes.

10.  Burn  wood  only.    Other  types  of  fuels  may  generate 

poisonous gases (e.g., carbon monoxide).

11.  If appliance burns poorly while an exhaust blower is on 

in home, (i.e., range hood), increase combustion air.

12.  Installation shall be in accordance with the Manufacturers 

Home & Safety Standard (HUD) CFR 3280, Part 24.

Approved for USA Installation only!

Mobile Home Installation

Summary of Contents for EXPLR-III-PBK

Page 1: ...s Do not touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as fireplace Alert children and adults to hazards of high tempe...

Page 2: ...fications 3 E Non Combustible Materials 3 F Combustible Materials 3 2 Getting Started 4 A Design and Installation Considerations 4 B Fire Safety 4 C Negative Pressure 5 D Tools And Supplies Needed 5 E...

Page 3: ...s Material which will not ignite and burn composed of any combination of the following Steel Plaster Brick Iron Concrete Tile Glass Slate Materials reported as passing ASTM E 136 Standard Test Method...

Page 4: ...e or air conditioning Imbalances of the HVAC air handling system Upper level air leaks such as Recessed lighting Attic hatch Duct leaks WARNING Asphyxiation Risk Negative pressure can cause spillage o...

Page 5: ...thout fully assembling all components Operating appliance without legs attached if supplied with appliance Do NOT Over fire If appliance or chimney connector glows you are over firing Any such action...

Page 6: ...nsible for use and operation ATTENTION INSTALLER Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjunction with not instead of the instructions con...

Page 7: ...Figure 7 1 Front View Figure 7 2 Side View 8 3 16 28 5 16 31 3 8 13 1 16 20 1 16 Figure 7 2 Top View 30 1 8 3 28 5 8 24 1 8 Center of Flue Figure 7 4 Side View with horizontal flue 3 Dimensions and Cl...

Page 8: ...door and measure 8 inches 203mm from the side edge of the opening in the face of the appliance See exception In Canada similar floor protection must be provided 18 inches 457mm in front and 8 inches 2...

Page 9: ...1 2 241 6 153 27 686 12 305 N A N A 52 1 2 1334 18 457 INSTALLATION HORIZONTAL THROUGH THE WALL SINGLE WALL PIPE N A N A 43 1 2 1105 25 1 2 648 N A N A 52 1 2 1334 N A For alcove only Six inch diamete...

Page 10: ...mney should Install through the warm space enclosed by the build ing envelope This helps to produce more draft espe cially during lighting and die down of the fire Penetrate the highest part of the ro...

Page 11: ...um 3 ft 91cm Minimum Wall or Parapet Flat Roof F 2 10 3 Rule These are safety requirements and are not meant to assure proper flue draft This appliance is made with a 6 inch 152mm diameter chimney con...

Page 12: ...el black or 26 gauge blued steel or an approved air insulated double wall venting pipe Thimble A manufactured or site constructed device installed in combustible walls through which the chimney connec...

Page 13: ...ide dimension frame from 2 x 2 framing lumber to fit into wall opening Inside opening of frame should be no less than 14 inch x 14 inch 356mm x 356mm Figure 13 1 4 Attach the wall spacer to the chimne...

Page 14: ...ppliance in a mobile home The listed connectors must conform to each other to ensure a proper fit and seal Flue Gas Direction Crimped End Toward Appliance Secure pipe sections with a minimum of 3 scre...

Page 15: ...ter to the appliance using 4 screws Figure 15 1 15 2 3 Floor Rear Installation Cut a 4 inch 102mm hole in outside wall or floor to accommodate outside air piping Use 4 inch 102mm aluminum metal flex o...

Page 16: ...et under the bottom left rear corner See Owner s Manual for detailed operating instructions for the blower and snap disc Shock Risk Do NOT remove grounding prong from plug Route cord away from applian...

Page 17: ...olt from each side of the flue transition and retrieve nuts attached to bolts 3 Turn flue transition to horizontal position Inspect rope gasket to ensure a leak free seal Re attach 4 Remove upper flue...

Page 18: ...inch 152mm factory built chimney conforming to CAN ULC 629M STANDARD FOR FACTORY BUILT CHIMNEYS 6 Follow the chimney and chimney connector manufacturer s instructions when installing the flue system f...

Page 19: ...sulation Blanket SRV7060 238 30 2 Baf e Blanket SRV7060 233 Y 30 3 Baf e Plate SRV7060 250 30 4 Baf e Board SRV7060 148 Y 30 5 Secondary Tubes Qty 3 req SRV7060 226 Y 30 6 Baf e Cover Plates SRV7060 2...

Page 20: ...eration DO NOT DISCARD Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com CONTACT INFORMATION This prod...

Reviews: