18
7062-197G
August 13, 2018
Explorer I
Convection Shroud
Flue Cover
Flue Transition
Figure 18.1
D. Reversible Collar & Horizontal Flue Shield
Tools Required:
#2 & #3 Phillips head screwdriver; 1/2"
wrench
The flue collar is reversible for either a top or rear venting
installation. The appliance is shipped with the flue collar in
the top vent position
(Figure 18.1)
.
Converting Collar Fo
r Rear Vent Installation
and Installing Required Horizontal Flue Shield
1.
Remove flue cover from convection shroud (5 Phillips
screws) as shown in
Figure 18.1
.
2. Remove convection shroud from appliance (4 Phillips
screws) as shown in
Figure 18.1
.
3.
Remove, rotate 180 degrees and install cast flue
transition in the horizontal position as shown in
Figures
18.1 and 18.2
.
4.
Install convection shroud on to the appliance
(Figure
18.2)
.
5.
Rotate 180 degrees and install the flue cover (Use
second set of provided holes) as shown in
Figure 18.2
.
Figure 18.2
C. Optional Fire Screen
An optional fire screen is available for the Explorer III.
Optional Fire Screen Part SCR-7061 may be used ONLY in
U.S. residential installations. Follow all safety warnings to
prevent any hazards.
Fire Risk.
•
Do not leave the fire unattended when the
door is unlatched or when using the fire
screen.
•
Unstable firewood could fall out of the
firebox creating a fire hazard to your home.
WARNING