50
Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19
K. Appliance Break-In
Follow the initial break-in procedure below to cure the
materials used to manufacture the fireplace and the
finishing materials around it.
• The fireplace should be run three to four hours
continuously on high flame and high fan.
• Turn the fireplace off and allow it to cool completely.
• Remove fixed glass assembly. See Section 9.A.
• Clean fixed glass assembly.
• Replace the fixed glass assembly and run continuously
on high an additional 12 hours.
NOTICE!
This product comes equipped with a fan that
provides remote control of heat output. See Section L.
Set the fan speed to high on the RC400 remote control
during the first three to four hours of break-in operation.
This break-in will ensure optimum speed control of the fan
during subsequent use.
Note:
The
IntelliFire™ Touch
system has a safety feature
that automatically shuts down the fireplace after 9 hours of
continuous operation without receiving a command from
the remote control. If this occurs, restart the appliance.
NOTICE!
Open windows for air circulation during fire
-
place break-in.
• Some people may be sensitive to smoke and odors.
• Smoke detectors may activate.
L. Heat Management
Heat Output
Heat Output is managed through the RC400 remote con-
trol that comes standard with the fireplace.
• Turn the appliance on and off.
• Adjust the height of the flame by varying the input using
the remote control.
• Adjust the fan speed.
For more information, see the instructions that accompany
the remote control.
NOTICE!
Set the fan speed to high on the RC400 remote
control during the first three to four hours of break-in
operation. This break-in will ensure optimum speed control
of the fans during subsequent use.