E. Hearth Extension
1/2 in.
Figure 3.16
Minimum Required 1/2 in. Gap to Bottom of Front
Y
X
Figure 3.17 Hearth - Combustible Material Exception
NO VINYL /
ADHESIVE FLOORING
• Combustible flooring may be located in front of the
appliance. Exception - no vinyl / adhesive flooring.
See Figure 3.17.
• 1/2 inch gap under the bottom of the front must be
maintained. See Figure 3.16.
• A minimum 1/4 inch gap from the bottom of the appliance
to the metal floor of the solid fuel firebox is
REQUIRED.
See side view in
Figure 3.18.
• Combustible flooring underneath the appliance is
acceptable with a 1/4 inch gap. See Figure 3.18.
Figure 3.18
Solid Fuel Floor Clearance
SIDE VIEW
MINIMUM 1/4 IN. REQUIRED
COMBUSTIBLE FLOOR UNDERNEATH APPLIANCE
Appliance Size
Depth (X)
Width (Y)
25 in.
16 in
25-3/4 in.
30 in.
16 in
30-3/4 in.
35 in.
16 in
35-3/4 in.
Vinyl / Adhesive Flooring - Minimums
Mantels - Combustible
Figure 3.15 Minimum Vertical and Maximum Horizontal
Dimensions - Combustible
Measurement to bottom
of appliance:
= 29-1/4 in. (25")
= 32-3/4 IN. (30")
= 36-1/4 IN. (35")
Measurement
from surround
opening.
12 in.
12 in.