background image

Page 2

Quadra-Fire  •  COLBAY-FS-B  •  250-5195 Rev. R  •  10/11

and Welcome to the Quadra-Fire Family

!

Hearth & Home Technologies welcomes you to our tradition 

of  excellence!    In  choosing  a  Quadra-Fire  appliance,  you 

have our assurance of commitment to quality, durability, and 

performance.
This  commitment  begins  with  our  research  of  the  market, 

including  ‘Voice  of  the  Customer’  contacts,  ensuring  we 

make  products  that  will  satisfy  your  needs.  Our  Research 

and  Development  facility  then  employs  the  world’s  most 

advanced technology to achieve the optimum operation of 

our stoves, inserts and fi replaces.  And yet we are old-fash-

ioned when it comes to craftsmanship.  Each appliance is 

meticulously  fabricated  and  gold  and  nickel  surfaces  are 

hand-fi nished for lasting beauty and enjoyment.  Our pledge 

to quality is completed as each model undergoes a quality 

control inspection.   From design, to fabrication, to shipping: 

Our guarantee of quality is more than a word, it’s Quadra-

Fire tradition, and we proudly back this tradition with a Lim-

ited Lifetime Warranty.  
We wish you and your family many years of enjoyment in the 

warmth and comfort of your hearth appliance.  Thank you for 

choosing Quadra-Fire.

SAMPLE OF SERIAL NUMBER / SAFETY LABEL

LOCATION: ON BACK OF APPLIANCE

Date

DO NOT REMOVE THIS LABEL / NE PAS 

ENLEVER L’ÉTIQUETTE 

Made in U.S.A. / Fait Aux États-Unis 

MINIMUM CLEARANCES TO COMBUSTIBLES 

ESPACE MINIMUM AUX COMBUSTIBLES 

Minimum clearances required from combustible construction for all 

appliance surfaces.  

Espaces minimum exigés de la construction combustible aux surfaces 

de l’appareil. 

250-5184 

 

This appliance equipped only for altitudes 0-2000’ (0-610m) in USA; and in Canada for altitudes of 0-4500’ (0-1370m). In USA for Altitudes above 2000’, the vent 

configuration, orifice, or combination of both may need to be changed. See Owner’s Manual for information on making these changes. 

Cet appareil est équipé pour les altitudes de 0-2000’ (0-610m) aux États-Unis; et au Canada pour les altitudes de 0-4500’ (0-1370m). Pour les altitudes au dessus de 2000’ 

aux États-Unis, la configuration du ventilateur, son orifice ou les deux peuvent possiblement avoir à être changé. Voyez le manuel du propriétaire pour les informations 

sur ces changements. 

 

This appliance must be installed in accordance with local codes, if any (and Commonwealth of Massachusetts approved); if none, follow the National Fuel Gas Code, ANSI 

Z223.1 or Canadian Installation Codes, CAN/CGA-B149. Install and use only in accordance with manufacturer’s installation and operating instructions. NOTE: Have the gas 

supply line installed in accordance with local building codes by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts, 

installation must be performed by a licensed plumber or gas fitter.) 

Cet appareil doit être installé en accord avec les codes locaux, s’il-y-a lieu (et approuvé par dans la République de Massachusetts); sinon lisez ANSI Z223.1/CAN 1-B149. 

Installez et utilisez en accords avec les instructions d’installation et d’opération du manufacturier. 

REMARQUE: Le conduit gaz doit être installé conformément aux codes 

de construction locaux. L'installation doit être effectuée par un technicien qualifeé et/ou muni d'une licence de manière à respecter les règlements municipaux. (Dans la 

République de Massachusetts, l'installation doit être effectuée par un plombier ou un installateur d'appareils à gaz agrée.) 

Keep burner and control compartment clean. See installation and operating instructions accompanying this appliance. This vented gas fireplace heater is not for use with air filters. 

Due to high surface temperatures, keep children, clothing and furniture away. 

Gardez le brûleur et le compartiment de contrôle propres. Vérifiez les instructions d’installation et d’opération qui accompagnent cet appareil. Cet appareil de chauffage au gaz n’est 

pas pour l’usage avec des filtres d’air. Du aux surfaces de températures élevées, gardez les enfants, les vêtements et les meubles à distance éloignée

FAN TYPE VENTED CIRCULATOR / VENTILATEUR CIRCULATOIRE 

Blower Electrical Rating / Évaluation du Ventilateur Électrique: 

115 V., 1.5 Amps, 60 Hz, 150 Watts 

Thermal Efficiency / Efficacité Thermique* 

  

84% NG (blower on / avec ventilateur allumé) 

 

86% LP (blower on / avec ventilateur allumé) 

* With Maximum horizontal length. / Avec longueur horizontale maximum. 

P.4.1-02 Canada Minimum pipe

 

(P.4.1-02 Le canada tuyau minimum) 

 

65.42% NG / 65.96% LP 

APPROUVÉ POUR LE CANADA ET LES ÉTATS-UNIS: 

ANSI Z21.88a-2001 / CSA 2.33a-M01 Fournaises au Gaz avec Ventilation, et les sections 

applicable de UL 307b Appareils de Chauffage Au Gaz pour les Maisons Mobiles et les 

Véhicules Motorisés, CAN/CGA 2.17-M91 “Gas Fired Appliances for use at High Altitudes”. 

Cet appareil est manufacturé pour l’opération avec le Gaz Naturel. Pour une conversion 

au gaz propane les pièces du Manufacturier #842-4041 et ses instructions doivent être 

utilisées. Cet appareil peut être utilisé dans une chambre à coucher ou salle de séjour; au 

Canada, l’installation d’un thermostat à distance est exigée. 

APPROVED FOR CANADA AND USA TO: 

ANSI Z21.88a-2001 / CSA 2.33a-M01 Vented Gas Fireplace Heaters, and applicable 

sections of UL307b Gas Burning Heating Appliances for Manufactured Homes 

and Recreational Vehicles, CAN/CGA 2.17-M91 “Gas Fired Appliances for use 

at High Altitudes.” This appliance is manufactured for operation with Natural 

Gas. For conversion to propane Manufacturer’s Part #842-4041 and instructions 

must be used. This appliance may be installed in a bedroom or bedsitting room; 

in Canada remote thermostat installation is required. 

HEARTH: A non-combustible hearth pad is not required. However, the 

floor beneath the stove must be stable, level, and strong enough to support 

the stove without a tipping hazard. 

CHEMINÉE: Un coussinet non-combustible de cheminée n’est pas 

exigé. Cependant, le plancher en dessous du poêle doit être droit, à 

niveau et assez fort pour supporter le poêle sans le hasard de 

basculer. 

 

  

For use with Natural Gas 

For use with Propane 

  

Usage Au Gaz Naturel 

Usage Au Gaz Propane 

  

0-2000’ 

0-2000’ 

Top Vent: Input Rate on “HI” (BTU/Hr) 

30,000 

30,000 

Puissance Évaluée à “HI” (BTU/Hr) 

 

Input Rate on “LO” (BTU/Hr) 

21,000 

24,500 

Puissance Évaluée à “LO” (BTU/Hr) 

 

Maximum Output (BTU/Hr)** 

25,250 

25,800 

Puissance Maximum (BTU/Hr)** 

 

Main Burner Orifice 

.1065 (36 DMS) 

.0635 (52 DMS) 

Orifice du Brûleur Principal 

Minimum Inlet Pressure (Inches W.C.) 

4.5” 

11” 

Pression Minimum de la Valve (pouces W.C.) 

Maximum Inlet Pressure (Inches W.C.) 

7.0” 

14” 

Pression Maximum de la Valve (pouces W.C.) 

Manifold Pressure on “HI” (Inches W.C.) 

3.5”                                            10”                   Pression du Collecteur d’ Échappement à “HI”  

 

 

 

 

(pouces W.C.) 

**Max Venting, Blower On 

 

 

** Ventilation Maximum, Ventilateur Allumé 

 

This appliance must be properly connected to a venting system in accordance with the manufacturer's installation instructions. 

Cet apprareil doit être correctement raccordé à un système d'évacuation, conformément aux instructions du fabricant. 

This appliance must be installed in accordance with the current Standard CAN/CSA Z240 MH, Mobile Housing or with Manufactured Home Construction and Safety Standard, 

Title 24 CFR, Part 3280, or when such standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installation Standard. 

WARNING: Do not operate the appliance until all sections have been assembled and installed in accordance with the manufacturer's instructions. 

Installer l'appareil selon la norme CAN/CSA-Z240, Serie MM, Maisons mobiles ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces 

normes ne sont pas pertineutes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard.

 

AVERTISSEMENT: Ne pas utiliser l'appareil tant que toutes les sections n'ont pas ete assemblees et installees selon les instructions du fabricant. 

A.  Side of stove top to side wall 

6 in. (152 mm) 

        Du coté du poêle au coté du mur 

A*.  In an Alcove 

6-3/4 in. (171 mm) 

        Dans l’alcôve 

B.  Rear of control box to back wall 

2 in. (51 mm) 

        Le contrôle arrière au mur arrière 

C.  Flue pipe to back wall 

6 in. (152 mm) 

        Du tuyau de cheminée au mur arrière 

D.  Flue pipe to side wall 

14 in. (356 mm) 

        Du tuyau de cheminée au mur du coté 

E.  Rear corner of stove top to side wall 

2 in. (51 mm) 

        Du coin arrière du poêle au mur de coté 

F.  Min. Floor to ceiling height (std. room) 

84 in. (2134 mm) 

        Hauteur minimum du plancher au plafond (pièce standard) 

G.  Top of stove to alcove ceiling 

19 in. (483 mm) 

        Du dessus du poêle au plafond de l’alcôve 

H.  Maximum alcove depth 

36 in. (914 mm) 

        Profondeur maximum de l’alcôve 

I.  Minimum alcove width 

36 in. (914 mm) 

        Largeur minimum de l’alcôve 

G- 

Alcove height 

Hauteur De 

l’Alcôve 

A* 

A* 

Date of Manufacture / Date du Manufacturier 

2005 2006 2007 

Feb  Mar  Apr  May  Jun  Jul  Aug  Sep  Oct  Nov  Dec 

Jan 

 

SA

MP

LE

 

MODEL / MODÈLE:  

COLUMBIA BAY 

Report  / Rapport  

061-S-19b-5 

  SERIAL  NO. 

800 West Jefferson Street

 Lake City, MN 55041

www.quadrafire.com

VENTED GAS FIREPLACE HEATER.  

NOT FOR USE WITH SOLID FUEL  

FOURNAISE AU GAZ AVEC VENTILATION 

NE PAS UTILISER AVEC LE COMBUSTIBLE SOLIDE 

002

Barcode

Summary of Contents for COLBAY-FS-B

Page 1: ...anufactured home USA only or mobile home and must be installed in accordance with the manufacturer s instructions and the manufactured home construction and safety standard Title 24 CFR Part 3280 or S...

Page 2: ...mum 65 42 NG 65 96 LP APPROUV POUR LE CANADA ET LES TATS UNIS ANSI Z21 88a 2001 CSA 2 33a M01 Fournaises au Gaz avec Ventilation et les sections applicable de UL 307b Appareils de Chauffage Au Gaz pou...

Page 3: ...rmination 12 G Vertical Termination 15 A Fuel Conversions 22 B Gas Pressures 24 C Gas Connection 24 A Recommendation for Wire 26 B Connecting to the Appliance 26 C Standing Pilot Ignition System Wirin...

Page 4: ...put BTU Minimum Input BTU Ori ce Size DMS Ef ciency Up To P 4 30 000 21 000 36 84 73 3 30 000 24 500 52 86 75 1 Manufactured Home or Mobile Home installation may occur only after the home is site loca...

Page 5: ...uilding at a minimum height of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in pri...

Page 6: ...glass door and set aside on pro tective surface Remove log set and component pack from rebox Report to your dealer any parts damaged in shipment particularly the condition of the glass fi Keep applian...

Page 7: ...speci cations in manual Model A A B C D E F G H I Columbia Bay FS Inches 6 6 3 4 2 6 14 2 84 19 36 36 Millimeters 152 171 515 152 356 51 2134 483 914 914 NOTE Flooring beneath appliance may reach 90 d...

Page 8: ...o 9 12 2 0 Over 9 12 to 10 12 2 5 Over 10 12 to 11 12 3 25 Over 11 12 to 12 12 4 0 Over 12 12 to 14 12 5 0 Over 14 12 to 16 12 6 0 Over 16 12 to 18 12 7 0 Over 18 12 to 20 12 7 5 Over 20 12 to 21 12 8...

Page 9: ..._____________________________________ _ _ QMIN RMAX 1 cap 3 feet 2 x Q ACTUAL 2 caps 6 feet 1 x Q ACTUAL 3 caps 9 feet 2 3 x Q ACTUAL 4 caps 12 feet 1 2 x Q ACTUAL QMIN termination caps x 3 RMA X 2 te...

Page 10: ...nnected to the ue Diagonal runs have both vertical and horizontal vent aspects when calculating the effects Use the rise for the vertical aspect and the run for the horizontal aspect See Two 45 elbows...

Page 11: ...If the vertical dimension from the center line of the ue vent to the center of the 90 elbow is 7 ft 2m the horizontal run to the outer wall ange must not exceed 13 ft 4m EXAMPLE 2 If the vertical dim...

Page 12: ...t vent sections per installation instructions Maintain all clearances to combustibles Do NOT allow vent to sag below connection point to appliance Maintain speci ed slope if required Improper support...

Page 13: ...of non hardening mastic around its outside edges so as to make a seal between it and the wall attach termination cap to the exterior wall with the four wood screws provided The arrow on the vent cap s...

Page 14: ...st be sealed with silicone with a minimum of 300 F continuous exposure rating Termination caps shall not be recessed into a wall or siding Fire Risk Explosion Risk Maintain vent clearance to combustib...

Page 15: ...on vertical runs is 1 ft 305mm ADDITIONAL RESTRICTION This installation may not have two horizontal sections connected by 90 elbows Check the installation instructions for required 1 in 25mm clearanc...

Page 16: ...sure that all pipe and elbow connections are in their fully twist locked position Assemble as instructed NOTE 1 If an offset is necessary in the attic to avoid obstructions it is important to support...

Page 17: ...ng sealant above and below the joint between the storm collar and the pipe OPTIONAL HIGH WIND TERMINATION CAP SECURE FLASHING WITH NON HARDENING SEALANT AND ROOFING NAILS CLEARANCE CEILING FIRESTOP NA...

Page 18: ...pport box to make a seal between it and the roof Clean out any combustible material from inside the support box Complete the cathedral ceiling installation by following the same procedures outlined in...

Page 19: ...p Ensure that you are drilling into the metal on the chimney Twist lock the high wind termination cap onto the top adapter Pull the flex pipe down through the ceiling support box until it protrudes ap...

Page 20: ...retro connector to mount directly on the masonry and provide the correct clearances to combustibles Secure the flashing to the top of the masonry chimney using a bead of non hardening sealant adhesiv...

Page 21: ...needed Be careful to ensure that the connector is centered in the opening and the mounting holes line up with the masonry wall Secure the top adapter to the flashing Use three sheet metal screws throu...

Page 22: ...th care With a 5 8 in wrench remove ori ce retaining nut Replace with appropriate ori ce KIT CONTENTS fi TOOLS REQUIRED Power drill a 90 handle is helpful 2 Phillips bit 5 32 in Allen wrench 5 8 in op...

Page 23: ...e explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The quali ed service agency is responsible for the proper installation of this conversio...

Page 24: ...g NOTE A listed and Commonwealth of Massachusetts approved 1 2 inch 13mm T handle manual shut off valve and exible gas connector are connected to the 1 2 inch 13mm control valve inlet NOTE The gap bet...

Page 25: ...s Do not use open ame After the gas line installation is complete all connections must be tightened and checked for leaks with a commercially available non corrosive leak check solution Be sure to rin...

Page 26: ...short as possible by removing any excess wire length 7 Low voltage and 110 VAC voltage cannot be shared within the same wall box 16 gauge 65 feet 18 gauge 40 feet 20 gauge 25 feet 22 gauge 18 feet Sh...

Page 27: ...trols Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Shock hazard Replace damaged wire with type 105O C rated wire Wire must have high temperature ins...

Page 28: ...accessories may be used safely IMPORTANT PREVENT PERMANENT STAINING 2 Screws 2 Screws Use a soft cloth and a window cleaning solution to clean all fingerprint oils from the gold or nickel surface of...

Page 29: ...sed with the brick set Install the left and right brick panels Use the screw placement shown in to secure them in place Reassemble appliance While still breakable the logs do not become fragile until...

Page 30: ...he existing door from the appliance Remove the crown from the existing door by removing four screws on the back side of the door assembly Pull crown off door face Install replacement door with glass o...

Page 31: ...eded retaining all fasteners and remove the blower Reassemble blower in housing using fasteners previously removed Reinstall blower housing to appliance Turn power supply back on TOOLS REQUIRED Philli...

Page 32: ...uch as to cause a sooty flame Improper adjustment can cause sooting in the firebox and or on the outside of a house with a horizontal termination After adjustment tighten nut to lock in place The vert...

Page 33: ...baf e adjustment Ensure that there are no gas leaks Ensure that the glass is sealed and in the proper posi tion Ensure that the ow of combustion and ventilation air is not obstructed front grilles and...

Page 34: ...ppliance May need to remove face front first 5 Push in gas control knob slightly and turn clockwise to the OFF position Do not force 6 Wait five 5 minutes to clear out any gas Smell for gas including...

Page 35: ...ting to sensitive individuals CAUTION Prevent accidental appliance operation when not attended Unplug or remove batteries from remote control if absent or if appliance will not be used for an extended...

Page 36: ...the gas valve is fully inserted and tight hand tighten plus 1 4 turn Disconnect the thermocouple from the valve place one millivolt lead wire on the tip of the thermocouple and the other meter wire o...

Page 37: ...into the system Check for proper vent connection at ue collar and all vent joints c Horizontal vent improperly pitched The horizontal vent cap should slope down only enough to prevent any water from e...

Page 38: ...ers Use a hard water deposit glass cleaner on white lm Do NOT clean glass when hot Turn off appliance after 3 4 hours of operation and ALLOW TO COOL Remove and clean glass assembly Replace glass assem...

Page 39: ...rforation Sand and repaint as neces sary 2 Replace appliance if rebox has been perforated Burner Ignition and Operation 1 Verify burner is properly secured and aligned with pilot or igniter 2 Clean of...

Page 40: ...Page 40 Quadra Fire COLBAY FS B 250 5195 Rev R 10 11...

Page 41: ...2 Dimensions are actual appliance dimensions Use for reference only For clearances refer to Section 3 A B F G H I J K C D E A 22 1 2 572 G 11 1 4 286 B 28 1 2 724 H 7 3 4 197 C 16 406 I 5 127 D 18 3 4...

Page 42: ...n 133 mm 25 1 4 in 641 mm 37 1 4 in 946 mm 49 1 4 in 1251 mm 13 1 4 in 337 mm 13 1 4 in 337 mm 6 5 8 in 168 mm 6 5 8 in 168 mm 6 5 8 in 168 mm 6 5 8 in 168 mm SLP45 SLP90 SLP12 SLP6 SLP4 SLP24 SLP36 S...

Page 43: ...op SLP WS Wall Firestop SLP HVS Pipe Support Hanger 950 Vinyl Protector Kit SL Pipe DRC RADIUS Decorative Radius Cover HTI DV WT Wall Thimble RF4 8 Roof Flashing TERMINATION KITS SLP TRAP2 Trapezoid T...

Page 44: ...n the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distribu...

Page 45: ...V D KHDWLQJ DSSOLDQFH VRPH FKDQJHV LQ FRORU RI LQWHULRU DQG H WHULRU VXUIDFH ILQLVKHV PD RFFXU 7KLV LV QRW D IODZ DQG LV QRW FRYHUHG XQGHU ZDUUDQW DPDJH WR SULQWHG SODWHG RU HQDPHOHG VXUIDFHV FDXVHG E...

Page 46: ...ce Do NOT discard this manual CAUTION Important operating and maintenance instructions included Read understand and follow these instruc tions for safe installation and operation Leave this manual wit...

Reviews: