Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15
15
Fire Risk.
When lining air-cooled factory-built chimneys:.
• Run chimney liner approved to UL 1777 Type HT
requirements (2100 degrees F)
• Re-install original factory built chimney cap ONLY
• DO NOT block cooling air openings in chimney
• Blocking cooling air will overheat the chimney
WARNING
Floor
Protector
Thimble,
12 in. (305mm)
Of Brick
Ceiling Joist
Combustible Wall
Airtight
Cleanout Door
Fireclay Flue Liner
With Air Space
Sheathing
Eave
1 in. (25mm) Clearance
With Firestop
Rafter
Flashing
Concrete Cap
Outside Air
Termination Cap
Outside Air Rear Vent
Spark Arrestor Cap
24” Min.
F. Masonry Chimney
WARNING
ONLY use connector:
• Within the room, between appliance and ceiling or wall.
Connector shall NOT pass through:
• Attic or roof space
• Closet or similar concealed space
• Floor or ceiling
Maintain minimum clearances to combustibles
Fire Risk.
Follow Chimney Connector Manufacturer’s
Instructions for Proper Installation.
Figure 4.7