background image

The Quadra-Fire 7100FP meets the 2015 US Enviornmen

-

tal Protection Agency’s crib wood emission limits for wood 

heaters sold after May 15, 2015.

Model:

7100FP

Laboratory:

OMNI Test Laboratories, Inc.

Report No:

061-S-41-2

Type:

Wood Fireplace

Standard:

UL 127 and ULC S610-M87 and 
(UM) 84-HUD, Manufactured  
Home Approved.

•  Installation and use of any damaged appliance. 
•  Modification of the appliance.
•  Installation  other  than  as  instructed  by  Hearth  &  Home 

Technologies.

•  Installation and/or use of any component part not approved by 

Hearth & Home Technologies.

•  Operating appliance without fully assembling all components.
•  Do NOT Overfire - If appliance or chimney connector glows, 

you are overfiring.

Any such action that may cause a fire hazard.

Listing and Code Approvals

A.  Appliance Certification

NOTE:  Hearth & Home Technologies, manufacturer of 

this appliance, reserves the right to alter its products, their 

specifications and/or price without notice.

C.  Mobile Home Approved 

  • 

This appliance is approved for mobile home installa

-

tions when not installed in a sleeping room and when 

an outside combustion air inlet is provided.

  • 

The structural integrity of the mobile home floor, ceil

-

ing, and walls must be maintained. 

  • 

The appliance must be properly grounded to the frame 

of the mobile home with #8 copper ground wire.

  • 

Outside Air Kit must be installed in a mobile home in

-

stallation.

Improper  installation,  adjustment,  alteration,  service  or 

maintenance can cause injury or property damage. 

For assistance or additional information, consult a qualified 

installer, service agency or your dealer.

Quadra-Fire is a registered trademark of Hearth & Home 

Technologies.

WARNING

Fire Risk.

Hearth & Home Technologies disclaims any 

responsibility for, and the warranty will be voided by, 

the following actions: 

B.  BTU & Efficiency Specifications

D.  Glass Specifications

This fireplace is equipped with 5mm ceramic glass.  Replace 

glass  only  with  5mm  ceramic  glass.    Please  contact  your 

dealer for replacement glass.

This wood heater needs periodic inspection and repair for 

proper operation. It is against federal regulations to operate 

this wood heater in a manner inconsistent with operating 

instructions in this manual.

EPA Certification #: 571 4-1-03

EPA Certified Emissions: 3.1 grams per hour

*LHV Tested Efficiency: 77.6 %

**HHV Tested Efficiency: 71.8%

***EPA BTU Output: 12,100 to 58,800 / hr.

****Peak BTU/Hour Output: 92,400

Vent Size: 8 inches

Firebox Size: 3.4 cubic feet

Recommended Log Length: 24 inches

Fuel

Seasoned Cord Wood

* * Weighted average LHV (Low Heating Value) efficiency using 

Douglas Fir dimensional lumber and data collected during EPA 

emission test.  LHV assumes the moisture is already in a vapor 

state so there is no loss in energy to vaporize.

****

Weighted average HHV (High Heating Value) efficiency using 

Douglas Fir dimensional lumber and data collected during EPA 

emission test.  HHV includes the energy required to vaporize the 

water in the fuel.

***

A range of BTU outputs based on EPA Default Efficiency and 

the burn rates from the low and high EPA tests, using Douglas 

Fir dimensional lumber.

****

A peak BTU out of the appliance calculated using the maxi

-

mum first hour burn rate from the High EPA Test and the BTU 

content of cordwood (8600) times the efficiency.

6

Quadra-Fire • 7100 FP Owner’s Manual • 433-3600 • Rev J • 09/21/15

Summary of Contents for 7100FP-GD-B

Page 1: ...nty Comply with all minimum clearances to com bustibles as specified Failure to comply may cause house fire WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death WARNING HOT SURFACES Glass and other surfaces are hot during operation AND cool down Hot glass will cause burns DO NOT touch glass until it...

Page 2: ...on 21 5 Fan Replacement 21 6 Timer Assembly Replacement 22 7 Timer Removal Replacement 24 5 Troubleshooting A FAQs 26 B Troubleshooting Table 28 6 Reference Materials A Service Parts 29 B Contact Information 36 1 Welcome A Congratulations 3 B LIMITED LIFETIME WARRANTY 4 2 Product Specific Information A Fireplace Certification 6 B BTU Efficiency Specifications 6 C Glass Specifications 6 3 Important...

Page 3: ...e glass only with 5mm ceramic available from your dealer Optional Fire Screen Part SCR 433 may be used ONLY in USA Chimney sections at any level require a 2 inches 51mm minimum air space clearance between the framing and chimney section Minimum Clearances To Combustible Material WITHIN ENCLOSURE AREA Appliance to backwall 1 2 13mm Appliance to sidewall 1 25mm Duct boots to framing 0 0mm Top stando...

Page 4: ...s on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period for parts and labor for covered components is produced in the...

Page 5: ... as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratches melted items or other external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes R...

Page 6: ...er service agency or your dealer Quadra Fire is a registered trademark of Hearth Home Technologies WARNING Fire Risk Hearth Home Technologies disclaims any responsibility for and the warranty will be voided by the following actions B BTU Efficiency Specifications D Glass Specifications This fireplace is equipped with 5mm ceramic glass Replace glass only with 5mm ceramic glass Please contact your d...

Page 7: ...e without fully assembling all components Improper installation adjustment alteration service or maintenance can cause injury or property damage 1 Clear Space Combustible materials must not be stored on the hearth extension Room furnishings such as drapes curtains chairs or other combustibles must be at least 4 ft 1219 mm from the open front of the fireplace Combustible materials are materials mad...

Page 8: ...iquids overload with wood burn trash or large amounts of scrap lumber permit too much air to the fire Symptoms of over firing may include one or more of the following air supply to the fire If you suspect a chimney fire call the fire department and evacuate your house Contact your local chimney professional and have your fireplace and chimney inspected for any damage Do not use your fireplace unti...

Page 9: ...PERVISE children in same room as fireplace Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away HOT SURFACES Glass and other surfaces are hot during operation AND cool down Automatic Combustion Air Control Handle Auxiliary Convection Air Lever ACC Override Le...

Page 10: ...e way to the right start the fire and then move the combustion air control to the desired burn level The fire will automatically go to that level once it is fully established This allows for less interaction with the fire by the homeowner and more efficient use of fuel while maintaining the desired heat output After the fireplace becomes hot you may prefer to not activate the ACC when reloading fu...

Page 11: ...om the duct and put it into the room as heated air Moving the lever all the way to the LEFT will cause the room air to be pulled into the bottom grille of the fireplace and re circulated into the room as heated air NOTICE If you live in an area with very cold winter months you will want to use room air as opposed to bringing in extremely cold air from outside of the home This will eliminate creati...

Page 12: ...place is hot and a good coal bed is established approximately 30 minutes after fuel is lit High Burn Setting The fan may be left on throughout the burn Medium or Medium High Burn Setting The fan should be left off until a good burn is established then turned on medium or high rate Low Burn Setting The fan tends to cool off the fireplace Leave fan off until the burn is well established then if you ...

Page 13: ...od can be as much water as it is wood having a moisture content of around 50 Imag ine a wooden bucket that weighs about 8 pounds Fill it with a gallon of water put it in the firebox and try to burn it This sounds ridiculous but that is exactly what you are doing if you burn unseasoned wood Dead wood lying on the forest floor should be considered wet and requires full seasoning time Standing dead w...

Page 14: ...m creosote The creosote vapors condense in the relatively cool chimney flue of a newly started or a slow burning fire As a result creosote residue ac cumulates on the flue lining When ignited creosote creates an extremely hot fire which may damage the chimney or even destroy the house The chimney shall be inspected at least annually be fore lighting or once every two months during heating season W...

Page 15: ... NOT store flammable materials close to the fireplace use gasoline lantern fuel kerosene charcoal lighter fluid or similar liquids to start or freshen up a fire in this fireplace Keep all flammable liquids well away from the fireplace while it is in use Combustible materials may ignite E Lighting Instructions To start a fire light easily ignitable tinder or paper which will ignite the fast burning...

Page 16: ...system at the fireplace connection and at the chimney top In the event of a chimney fire Hearth Home Technologies recommends replacement of the chimney and inspection of the adjacent structure to the provisions of NFPA Level III inspection criteria WARNING Risk of Asphyxiation and Fire Annual inspection by qualified technician recommended Check condition of doors surrounds and fronts condition of ...

Page 17: ...replace to cool completely Remove baffle and ceramic blanket from fireplace before cleaning chimney refer to Section 5 C 3 Baffle Removal and Installation Close the door tightly Remove the top of the termination cap as shown in Figure 4 1 to clean the cap and chimney The creosote or soot should be removed from the chimney with a brush specifically designed for the size of chimney in use Reinstall ...

Page 18: ... Replace if this condition is present Inspect glass gasket Confirm glass does not move around in glass frame Warning Risk of Fire Do not remove ashes until the fire is out and the fireplace is cold Ashes should be placed in metal container with tight fitting lid The closed container of ashes should be placed on a noncombustible floor or on the ground well away from all combustible materials pendin...

Page 19: ...ely a few turns at a time until the glass panel is tightened snugly DO NOT OVERTIGHTEN OR CROSS THREAD SCREWS Replace the door on the fireplace After the first burn recheck the tightness of the screws NOTICE Remove all labels from glass before lighting the first fire in your fireplace Latch Cam Spacing Washers Door Handle Shaft Fiber Handle Right Door Locknut Left Door Black Washer DO NOT REMOVE S...

Page 20: ...e coals are completely cooled remove all old firebrick and ash from unit and vacuum out firebox Remove new brick set from box and lay out to diagram shown in Figure 4 3 Lay bottom bricks in unit Install rear bricks on the top of the bottom bricks Slide top of bricks under clip on back of firebox wall and push bottom of brick back Install side bricks Slide top of brick under clips on side of firebo...

Page 21: ...en wrench remove the front manifold tube retainer bolt on the air channel under the end of the front tube See Figure 4 6 NOTICE Soak the bolt with penetrating oil for at least 15 minutes before trying to remove it To remove manifold tube slide the tube to one side until one end is out of its hole Then while lifting that end of the fiber board baffle pull tube up over the air channel and out of hol...

Page 22: ...en access door Remove both doors outside air knobs fascia and brick Remove two Phillips head screws and pry open access door in the bottom of the fireplace with a flat head screwdriver See Figure 4 11 Remove two screws and take off access cover shown in Figure 4 12 NOTICE The timer assembly included in this kit comes with the air chamber cover attached Figure 4 13 You will need to disconnect air c...

Page 23: ...e Figure 4 16 Remove Screws from Timer Mounting Plate Rotate assembly up and out through access door Arm must be in this position when re installing Figure 4 17 Hand in Access Door Figure 4 18 Removing Timer Assembly Remove old air chamber cover Place the cover under the bottom of the firebox Using a 7 16 wrench attach the two 1 4 20 bolts as shown in Figure 4 19 If installing a new timer skip to ...

Page 24: ... Replacement Loosen set screw on timer remove two screws and remove timer See Figure 4 21 Figure 4 20 Timer Box Installed D cut side of timer shaft must face away from the Linkage Timer Arm Place linkage control arm over timer shaft and tighten set screw Figure 4 23 Tighten set screw Figure 4 23 Linkage Control Arm Installed Rotate linkage control arm into final position and re attach to mounting ...

Page 25: ...cription Qty 1 Door Linkage 1 2 Linkage Control Arm 1 3 Bushing 2 4 Washer SAE 10 2 5 Screw 8 32 x 1 2 PH PHL TC 2 6 Linkage Timer Arm 1 7 Attachment Nut Set Screw 1 8 Screw 6 32 x 1 4 PH PHL TC 2 9 Mounting Bracket 1 10 Timer Mechanical 12 hours 1 25 Quadra Fire 7100 FP Owner s Manual 433 3600 Rev J 09 21 15 ...

Page 26: ...onry chimney Try holding a burning rolled up newspaper as close to the flue outlet as pos sible for a few minutes then light the paper under the kindling The heat generated from the burning rolled up newspaper should help get the draft established Still other factors can affect how well your flue system performs Neighboring structures high winds tall trees even hillsides can affect air currents ar...

Page 27: ... Outside air closed Overhead fan operating Overhanging tree Bird s nest or leaves in termination cap Structural changes in chimney area Creosote buildup in flue Strong win d s a r o u nd chimney termination Unsealed can lights Combustion air control Figure 5 1 Factory built Fireplaces Troubleshooting 27 Quadra Fire 7100 FP Owner s Manual 433 3600 Rev J 09 21 15 ...

Page 28: ...heck and clean chimney if needed Check door rope for seal Open air controls ACC Smoke in the house during refueling Open air controls ACC to establish a lively coal bed Open doors SLOWLY Add progressively larger wood to establish a hot fire Fuel burns too fast ACC not working properly Wood too dry mix in less seasoned wood after the fire is established User larger diameter wood Check baffle cerami...

Page 29: ...Active Woodburning Fireplace Part number list on following page MISSION HILL FASCIA VALLEY FORGE FASCIA 1 2 3 4 5 6 7 8 9 12 10 11 13 14 15 16 17 18 7100FP BK B 7100FP GD B and 7100FP NL B Aug 2006 Active 7100FP BK 7100FP GD and 7100FP NL Mar 2005 July 2006 09 15 29 Quadra Fire 7100 FP Owner s Manual 433 3600 Rev J 09 21 15 ...

Page 30: ...SRV480 1940 Y 7 Brick Assembly Complete Set Pkg of 27 BRICK 433 7 1 Brick 9 x 3 25 x 1 25 Angled see diagram Qty 2 Req 433 6080 7 2 Brick 6 25 x 4 5 x 1 25 Qty 5 Req 433 6090 7 3 Brick 9 x 2 x 1 25 Qty 2 Req 433 6110 7 4 Brick 6 25 x 3 5 x 1 25 Qty 2 Req 433 6120 7 5 Brick 9 x 4 5 x 1 25 Qty 16 Req 832 2370 Brick Uncut Clay Pkg of 6 832 3030 8 Fascia Mission Hill Pre 0071580458 DF 7100MH Post 0071...

Page 31: ...e Top 433 1610 13 2 Glass Frame Bottom 433 1620 13 3 Glass Assembly Qty 2 req 433 5750 Y Gasket Rope 1 4 Black Glass Field Cut to Size 10 Ft 834 1460 Y 13 4 Hinge Pin Gold 229 1240 Nickel 229 1250 10 Y 13 5 Washer 1 4 Sae Pkg of 24 28758 24 Y Door Handle Kit HANDLES 433 Y 13 6 Handle Door Left 433 2030 13 7 Handle Door Right 433 0770 13 8 Fiber Handle SRV433 1380 Y 13 9 Key Cam Latch 430 1151 13 1...

Page 32: ...Y Brick Retainer Assembly SRV433 5860 Y Bypass Lever Assembly SRV433 5850 Y Chimney Air Kit CAK4A Outside Air Shield 33271 Y Collar Set 1 4 229 0750 Component Pack Includes Clamp Connector Knob Owners Manual Epa Label Sales Ef ciency Light Switch Light Switch Cover Plate Fan Speed Control Touch Up Paint Quadra Fire Warranty Card 433 5180 Control Arm Assembly 433 5880 Face Board Assembly Non combus...

Page 33: ...T ZONE WOOD Dv Adapter 7010 172 Fan Heat Zone 7015 003 Return Air Grille 12 x 6 7015 110 Unit Collar 659 125 Lintel Bar LINTEL 433 Template Metal TMP 433 TR Top Vent Kit TR TVK FASTENERS Avk Rivnut Repair Kit 1 4 20 3 8 16 Rivnut Tools RIVNUT REPAIR Y Nut Capped Push 1 4 Pkg of 24 7000 157 24 Y Nut Keps Lock 8 32 Pkg of 40 226 0060 40 Y Nut Ser Flange Small 1 4 20 Pkg of 24 226 0130 24 Y Screw PH ...

Page 34: ...This page intentionally left blank 34 Quadra Fire 7100 FP Owner s Manual 433 3600 Rev J 09 21 15 ...

Page 35: ...This page intentionally left blank 35 Quadra Fire 7100 FP Owner s Manual 433 3600 Rev J 09 21 15 ...

Page 36: ...019099 6048195 6053165 6145502 6170481 6237588 6296474 6374822 6413079 6439226 6484712 6543698 6550687 6601579 6672860 6688302 6688302B2 6715724B2 6729551 6736133 6748940 6748942 6769426 6774802 6796302 6840261 6848441 6863064 6866205 6869278 6875012 6880275 6908039 6919884 7047962 7216645 D320652 D445174 D462436 Canada 1297749 2195264 2225408 2313972 Australia 780250 780403 1418504 or other U S a...