Page 36
7047-148C
December 20, 2011
R
51I ACC Wood Insert
Minimum Width of Cavity Opening - Front 29-1/16
738
Minimum Width of Cavity Opening - Rear
25-1/2
648
Minimum Height
20-3/4
528
Minimum Depth from Front to Rear
17-9/16
446
Inches
Millimeters
The following modifications of factory-built fireplaces are
permissible:
•
The fireplace must not be altered. Cutting any sheet
metal parts of the fireplace in which the fireplace insert is
to be installed is prohibited per ANSI Z21.88 except that
the damper may be removed to accommodate a direct-
connect starter pipe or chimney liner,
• E
xternal trim pieces which do not affect the operation
of the fireplace may be removed providing they can be
stored on or within the fireplace for reassembly if the
insert is removed.
•
The permanent metal warning label provided in the
component pack must be attached to the back of the
fireplace, with screws or nails, stating that the fireplace
may have been altered to accommodate the insert,
and must be returned to original condition for use as a
conventional fireplace.
Figure 36.2
.
•
If the hearth extension is lower than the fireplace opening,
the portion of the insert extending onto the hearth must
be supported.
•
Manufacturer designed adjustable support kit can be
ordered from your dealer.
•
Final approval of this installation type is contingent upon
the authority having jurisdiction.
Damper
Smoke Shelf or Baffle
Ember Catches
Fire Grate
Viewing Screen/Curtain
Doors
The following parts may be removed:
Fire Risk.
When lining air-cooled factory-built chimneys:.
• Run chimney liner approved to UL 1777 Type
HT requirements (2100 degrees F)
• Re-install original factory built chimney cap
ONLY
• DO NOT block cooling air openings in chimney
• Blocking cooling air will overheat the chimney
WARNING
Prefabricated Metal Chimney (Cont’d)
LINER CONNECTOR
FLUE
GAS
DIRECTION
CRIMPED
END
TOWARDS
STOVE
Figure 36.1
NOTICE: In Canada when using a factory-built chim
-
ney it must be safety listed, Type UL103 HT (2100oF)
[1149oC] CLASS “A” or conforming to CAN/ULC-
S629M, STANDARD FOR 650oC FACTORY-BUILT
CHIMNEYS.
NOTE: Refer to chimney liner manufacturer for recom-
mendations on supporting the liner. Installtion into
fireplaces without a permit will void the listing.
H. Altering the Fireplace
G. Securing Chimney Components
All joints should be secured with 3 sheet metal screws or
rivets per pipe manufacturers instructions. The sections must
be attached to the insert and to each other with the crimped
(male) end pointing toward the insert.
Figure 3.1
.
WARNING! Risk of Fire!
Follow venting manufacturer’s clearances and instructions
when installing venting system.
250-2061
WARNING
THIS FIREPLACE MAY HAVE BEEN ALTERED
TO ACCOMMODATE AN INSERT. IT MUST BE
RETURNED TO ITS ORIGINAL CONDITION
BEFORE USE AS A SOLID FUEL BURNING
FIREPLACE.
250-2061
Heath & Home Technologies
250-2061
5.5 in. width x 2 in. height
NON. ANOD. ALUM BLACK LETTERS ON SILVER
with 1/8 in. holes on both sides.