Page 22
7047-148C
December 20, 2011
R
51I ACC Wood Insert
5
Service Parts Replacement
A. Glass Replacement - Door Assembly
(Replace with 5mm ceramic glass only)
1. Ensure that the fire is out and the appliance is cool to the
touch.
2. Protect a table or counter top with padding or towels.
Protect your hands and wear gloves to prevent injury.
3. Remove the door with the broken glass by lifting the door
up and off of the hinges.
4.
Lay door face down on a table or counter making sure the
handle hangs over the edge so the door lays flat, on a soft
surface.
5. Remove the screws from each glass retainer and remove
the glass. (If screws are difficult to remove, soak with
penetrating oil first).
6. Center the glass with edges evenly overlapping the open
-
ing in the door, (i.e. same space top and bottom, left and
right sides).
7. Replace the glass retainers. Be careful not to cross
thread the screws.
8. Tighten each retainer just a few turns until each is
secured. Check again for centering of glass in door
frame. Continue to tighten each retainer alternately, a
few turns at a time, until the glass is secure. DO NOT
OVERTIGHTEN - can cause glass to break.
9. Replace the door on the appliance.
Quadra-Fire appliances are equipped with ceramic super
heat-resistant glass, which can only be broken by impact or
misuse.
WARNING! Risk of Fire or Injury!
Use only glass that is specified in the manual, DO NOT
replace with any other material. Glass breakage will occur.
CAUTION!
Handle glass with care.
• Inspect the gasket to ensure it is undamaged.
• Do NOT strike, slam or scratch glass.
• Do NOT operate appliance with glass & door assembly
removed.
• Do NOT operate with glass cracked, broken or
scratched.
1.
Using a 5/32 Allen wrench remove the 4 screws from the
blower housing, 2 on each side. and pull the housing away
from the appliance.
Figure 22.1.
2. Remove the blower shield assembly using a Phillips head
screwdriver and remove the 4 screws. Disconnect snap
disc from the wire harness.
Figure 22.2.
3. Turn the blower assembly upside down and disconnect the
blower the the wire harness.
4. Remove the 4 blower mounting screws using a Phillips head
screwdriver. Slide blower off of blower mounting bracket.
Figure 22.3.
5. Install new blower and attach to housing and appliance in
reverse order.
B. Blower Replacement
Assemblée
Bouclier ventilateur
Retirez les 4 vis
Remove 4 screws and
pull housing away from
appliance
Figure 22.1
Figure 22.2
Blower Mounting Bracket
Remove 4 screws
Figure 22.3
Shock Risk
.
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded 3 prong
receptacle.
• Route cord away from appliance.
• Do NOT route cord under or in front of appliance.
CAUTION