background image

28

02/23

7037-807C

Service Parts

R

43ST-ACC-AU

Beginning Manufacturing Date: May 2021 

Ending Manufacturing Date: Active

IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer 

or distributor. 

Hearth and Home Technologies does not sell directly to consumers

Provide model number and serial number when requesting service parts from your dealer 

or distributor.

Stocked 

at Depot

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

10

Rear Channel Assembly

SRV7033-002

Y

11

Tube Support Rack

SRV7033-148

12

Brick Retainer

SRV7033-149

13

Ceramic Fiber Blanket, 1/2 “ Thick

832-3390

Y

14

Baffle Board - 9-1/2” W x 15-3/4” H

Qty: 2

SRV7037-112

Y

Baffle Protection Channel

SRV7033-298

15

Heat Shield

SRV7037-169

Label, Burn Rate

SRV7033-160

16

Label, Start-Up, Acc

SRV7033-166

17

Panel Assembly, Side, Right

SRV7037-010

18

Tube Channel Top - Access Cover

SRV7033-237

19

Tube, Channel Assembly

Manifold Tubes

SRV7033-023

Y

Gasket, Manifold

Pkg of 4

7038-168/4

Y

20.1

Burn Rate Control Assembly

SRV7037-004

Y

20.2

Spring Handle, 1/4”

Nickel

250-8340

Y

20.3

Door Gasket - Front & Rear Air Timer Doors

7033-282

Y

20.4

Timer Air Control Assembly

SRV7037-021

Y

Rear Air Door Assembly

SRV7037-013

Y

20.5

Rear Air Control Arm Assembly

SRV7037-005

Y

20.6

Knob - Start-Up Control Knob

SRV7000-343

20.7

Air Control Rod Guide

SRV7033-210

20.8

Latch, Magnet - For Air Control

SRV229-0631

20.9

Timer Arm Assembly

SRV7033-034

Y

20.10

Timer (Only) Replacement Assembly

SRV480-1940

Y

Additional service part numbers appear on following page.

 & Associated Parts

Baffle Protection Channel

#20 Burn Rate Controls 

Fiber baffle

Ceramic blanket

This tab sits behind the front tube.

Baffle protection Channel sits

In between Front tube and 

Fiber baffle.

Side view

Front, looking into unit

20.1

20.2

20.3

20.4

20.5

20.6 20.7

20.8

20.9

20.10

Summary of Contents for 43ST-ACC-AU

Page 1: ...ed Failure to comply may cause house fire If the information in these instructions is not followed exactly a fire could result causing property damage personal injury or death WARNING WARNING HOT SURF...

Page 2: ...AGE PARTICULATE EMISSION FACTOR WHEN TESTED IN ACCORDANCE WITH AS NZS 4013 0 4 g kg 1 0 g kg MAXIMUM AVERAGE HEAT OUTPUT 10 kW 12 kW APPROVED FUEL BURN ONLY WOOD WITH A MOISTURE CONTENT LESS THEN 25 d...

Page 3: ...eneral Maintenance 17 D Correct Baffle Blanket Placement 19 4 Troubleshooting Guide 20 5 Service Part Replacement 21 A Glass Replacement Door Assembly 21 B Firebrick Replacement 21 C Door Handle Assem...

Page 4: ...ective in materials or workmanship during the applicable warranty period HHT will at its option repair or replace the covered components HHT at its own discretion may fully discharge all of its obliga...

Page 5: ...d is not covered under warranty Damage to printed plated or enamelled surfaces caused by fingerprints accidents misuse scratches melted items or other external sources and residues left on the plated...

Page 6: ...d to improper chimney or venting installation HOW TO CLAIM To make a claim against this warranty contact your local distributor during regular business hours See addresses below for a dealer nearest y...

Page 7: ...D KINDLING LIGHT THE PAPER ADD MORE WOOD REDUCE AIR CONTROLS Set to desired heat output LOW BURN RATE CONTROL Upper Right Corner AUTOMATIC COMBUSTION CONTROL ACC Middle right hand side LOW The applian...

Page 8: ...Size 6 inches Firebox Size 2 3 cubic feet Recommended Wood Length 18 inches Fuel Orientation Front to Back Approved Fuel Softwood and Hardwood only with a Moisture content less than 25 dry basis Impr...

Page 9: ...r wood sizzles in the fire even though the surface is dry it may not be fully cured Splitting wood before it is stored reduces drying time Wood should be stacked so that both ends of each piece are ex...

Page 10: ...amount of heat needed to dry and rekindle the next load of wood It is best to open the Burn Rate Air and Start Up Air Controls before reloading This livens up the coal bed and reduces excessive emissi...

Page 11: ...teAir Control spring handle up to high position for 5 minutes Then activate the ACC timer system by pushing the knob all the back toward the appliance to HI then pull forwards towards the front of the...

Page 12: ...sticks of kindling on top of the paper 6 Make sure that no matches or other combustibles are in the immediate area of the appliance Be sure the room is adequately ventilated and the flue unobstructed...

Page 13: ...NOT burn treated wood or wood with salt driftwood May generate carbon monoxide if burn material other than wood May result in illness or possible death WARNING When burning your first fire you will ex...

Page 14: ...o find a dealer ISSUES SOLUTIONS Odor from appliance When first operated this appliance may release an odor for the first several hours This is caused by the curing of the paint and the burning off of...

Page 15: ...vent cap blockage and creosote build up Firebrick Ash Removal WEEKLY or after every 25 loads of wood Ashes must be cool before you can dispose of the ashes in a non combustible container Firebrick is...

Page 16: ...apidly move the ARS latch handle up and down to help remove any ash from the door Use a small brush to clean off the top of the door if any ash remains Be sure to replace the cap before operating the...

Page 17: ...e The chimney connector and chimney should be inspected once every 2 months during the heating season to determine if a creosote or soot buildup has occurred If creosote or soot has accumulated it sho...

Page 18: ...leaner left on during the next firing can permanently stain the glass and damage the finish on metal surfaces A portion of the combustion air entering the firebox is deflected down over the inside of...

Page 19: ...CORRECT POSITION Ceramic Blanket and Baffle Board MUST be in contact with the back of the firebox and even with each other in the front WARNING Fire Risk Firebox damage due to improper baffle placeme...

Page 20: ...uate vent height refer to Chimney Height Section Open window below the appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to Seasoned Wood Section Bed of coals...

Page 21: ...is out and the appliance is cool to the touch 2 Protect a table or counter top with padding or towels Protect your hands and wear gloves to prevent injury 3 Remove the door with the broken glass by l...

Page 22: ...install the baffle pieces one piece at a time Be sure the baffle boards are even with the front manifold tube and is resting on all tubes Figure 22 3 5 To re install the ceramic blanket it is easier t...

Page 23: ...hannel assembly a clearance of 483mm is required on the right side of appliance in order to remove the tubes with the appliance in place If space is not available the appliance will have to be disconn...

Page 24: ...24 02 23 7037 807C A Service and Maintenance Log Date of Service Performed By Description of Service 6 6 Reference Materials...

Page 25: ...25 02 23 7037 807C Date of Service Performed By Description of Service...

Page 26: ...Parts List Service Parts R 43ST ACC AU Beginning Manufacturing Date May 2021 Ending Manufacturing Date Active Step Top Model Wood Stove Part number list on following page 02 23 1 2 3 4 5 6 7 8 9 10 1...

Page 27: ...4 5 x 1 25 Qty 11 Reg 832 0550 4 2 Brick 6 x 4 5 x 1 25 Qty 4 Reg SRV7128 002 4 3 Brick 4 5 x 4 5 x 1 25 Qty 2 Reg SRV7128 001 4 4 Brick 9 x 4 5 x 1 25 with angle Qty 1 Reg SRV7128 806 4 5 Brick 9 x 3...

Page 28: ...t SRV7037 010 18 Tube Channel Top Access Cover SRV7033 237 19 Tube Channel Assembly Manifold Tubes SRV7033 023 Y Gasket Manifold Pkg of 4 7038 168 4 Y 20 1 Burn Rate Control Assembly SRV7037 004 Y 20...

Page 29: ...KIT NL 21 1 Ash Pan Assembly SRV7033 008 21 2 Legs Queen Anne Black 831 1240 Nickel LEGS QANL 21 3 Ash Pan Leg ARS Ash Pan Removal System SRV7033 050 21 4 Leg Mount Kit SRV7037 132 Component Pack Leg...

Page 30: ...Door Assembly Required to Complete Option Black DR 31 43BK FH Y Nickel DR 31 43NL FH Y 23 1 Hinge Pins 1 2 Black 7000 606 2 Y Nickel SRV430 5320 23 2 Rope Door 3 4 x 84 Field cut to Size 7 Ft Length...

Page 31: ...ption DR 31RCT Y 25 1 Hinge Pins 1 2 Black 7000 606 2 Y 25 2 Glass Assembly SRV7044 027 Y Gasket Glass Tape Field cut to Size 5 Ft Length 832 0460 Y 25 3 Glass Frame Set Qty of 2 SRV7044 191 25 4 Scre...

Page 32: ...39 Outside Air Shield SRV33271 Y Upgrade Door Nickel Handles Hinge Pins Logo Nickel UK DRNL Logo Quadra Fire Pkg of 10 7000 649 10 Cast Legs Black Set of 4 TRAD LEG BK FASTENERS Avk Rivnut Repair Kit...

Page 33: ...33 02 23 7037 807C...

Page 34: ...maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We...

Reviews: