background image

PLEASE LEAVE THIS MANUAL WITH THE OWNER !!

Listed by W arnock Hersey

THIS UNIT APPRO VED FO R M OBILE HO M ES

FAILURE TO FOLLOW  THESE INSTRUCTIONS M AY

RESULT IN PROPERTY DAM AGE, BODILY INJURY,

OR EVEN DEATH.

CAUTION: IN A M OBILE HOM E INSTALLATION, THE
STRUCTURAL INTEGRITY OF THE M OBILE HOM E
FLOO R, W ALL, AND CEILING/ROO F M UST BE
M AINTAINED.

YOUR SIERRA CRICKET 5300 HAS BEEN TESTED
BY WARNOCK-HERSEY LABORATORIES TO ANSI/UL
STANDARD 1482, UL 737.

W ARNING: DO NOT INSTALL IN SLEEPING ROOM
IF THE UNIT IS IN A M OBILE HO M E.

SAFETY NO TICES

<

CAUTION: HO T W HILE IN OPERATION. KEEP
CHILDREN, CLOTHING AND FURNITURE AW AY.
CONTACT M AY CAUSE SKIN BURNS.

<

IF THIS HEATER IS NOT PROPERLY INSTALLED,
A HOUSE FIRE M AY RESULT.

<

CONTACT LOCAL BUILDING  O FFICIALS ABOUT
RESTRICTIONS AND INSTALLATION INSPECTION
REQUIREM ENTS IN YOUR AREA.

<

FAILURE TO COM PLY W ITH OW NERS' M ANUAL
INSTRUCTIONS W ILL VOID YOUR W ARRANTY!

<

DO  NOT USE CHEM ICALS OR FLUIDS TO START
OR “FRESHEN UP” THE FIRE!

<

DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS.

DO NOT CONNECT TO  ANY AIR DISTRIBUTION DUCT

OR  SYSTEM .
DO NOT CONNECT THIS APPLIANCE TO A CHIM NEY

FLUE SERVING ANOTHER APPLIANCE.

Sierra Cricket Model 5300
Wood Heater Insert Manual
Installation & Operating Instructions

Please read this entire manual before installation. Save these instructions.

GENERAL INFORMATION

W e wish to welcom e you as a new owner of a SIERRA
W oodstove.  You join m any thousands of happy owners who
have been heating with SIERRA stoves since 1972.  SIERRA
stoves have changed a great deal during that tim e, and all of
our knowledge and experience have culm inated in this stove,
the SIERRA CRICKET Model 5300. Please read this entire
m anual before you install and use your new room  heater,
especially if you have owned another woodstove in the past.
W e at SIERRA wish you m any happy years of warm th and
com fort.

Designed with you, the consum er, in m ind, your SIERRA
5300 provides the versatility of five possible installation
applications, including both m asonry and zero clearance
fireplaces, freestanding with optional pedestal, corner or
alcove placem ent, and m obile hom e approval.
Its optional jacket and blower package insures good
clearances to com bustibles, and extrem ely clean glass and
the ability to m eet the m ost stringent clean air requirem ents
with catalytics insures ease of m aintenance.

This m anual describes the installation, operation and
m aintenance of the SIERRA CRICKET m odel num ber 5300
non-catalytic wood heater.

 

Your SIERRA generates a lot of heat, so treat it with care.
Read this m anual thoroughly before installing and  operating
your stove.

 

SAFETY NOTICE

If this appliance is not properly installed, a house fire m ay
result. For your safety, follow the installation instructions.
Check with local building or fire officials about restrictions and
installation inspection requirem ents in your area.

 

It is best to have a professional install your Sierra Stove. If you
prefer to install it yourself (see Installation Instructions), be
sure to obtain the proper perm its. Have the local building
officials inspect the stove and chim ney pipe for safety and
code com pliance after the installation is com plete.

Summary of Contents for Cricket 5300

Page 1: ...stoves have changed a great deal during that time and all of our knowledge and experience have culminated in this stove the SIERRA CRICKET Model 5300 Please read this entire manual before you install and use your new room heater especially if you have owned another woodstove in the past W e at SIERRA wish you many happy years of warmth and comfort Designed with you the consumer in mind your SIERRA...

Page 2: ... to small or large in diameter or too short can cause your stove to spill smoke when the door is opened Have your existing chimney inspected before attaching the cricket to it Some chimney must be relined or replaced before they are safe to use This room heater must be connected to 1 a chimney complying with the requirements for type H chimneys in the standard for chimneys factory built residentia...

Page 3: ...ing are general guidelines for a safe installation and are based on recommendations of the National Fire Protection Association NFPA Contact your local building code agency or fire safety inspector for specific details Local codes may vary by area 1 The chimney should have a fire clay liner in good condition Loose or cracked liner sections can be hazardous If the chimney does not have a liner one ...

Page 4: ...r surface of brick wall to but not beyond the inner surface of chimney flue liner and shall be firmly cemented in place B Solid insulated listed factory build chimney length of the same inside diameter as the chimney connector and having 1 inch or more of insulation with a minimum 9 inch air space between the outer wall of the chimney length and combustibles C Sheet steel chimney connector minimum...

Page 5: ...5 Your local building code agency or fire safety inspector can refer you to a qualified professional who can inspect the chimney for you Typical Factory Built or Masonry Chimney Installations ...

Page 6: ... HC Preway Models DW 36 DW 36A DL36DW DW 42 FF42 DL42DW BE48 PB48 FF48 BE41 FF41 BE41ST B142D FF36 B136SEM DL360A5 BE41SEM B136D 3M B136D DL36DOA PB4250 DL36D SL36PB Martin Models BC3642 BC3642M BB3642 BB3642C A39 AC39 A33 AC33 A AC36 A42 AC42 DBB36 DBC36 BW 36B BW 42B B 36 C 36 C 36M DBB361 DBC361 M42 M36 BB4250 BB4250C BC4250 BW 4245A LF36B Superior Models SP38C 1 RD 3300 RD 3800 RD 4300 RC 3310...

Page 7: ...ipe should extend into the fireplace chimney at least 18 DO NOT USE GLASS OR FIBERGLASS AS IT WILL MELT DUE TO EXTREME HEAT 7 Adjust the stove pipe to approximately the height of the flue collar 8 Slide the unit into the fireplace and center the flue collar under the stove pipe 9 Slide the stove pipe or slip joint into the flue collar as far as possible DO NOT BREAK THE SEAL OF THE REFRACTORY CEME...

Page 8: ... liner is neither too small or too large for the stove you wish to use Either your SIERRA woodstove dealer or a qualified chimney sweep should first inspect your chimney If your chimney is lined with a clay tile liner which is no smaller than 6 x 6 or larger than 8 x 12 inside measurements you may install the Cricket in your fireplace The general accepted rule is the cross sectional area of the ch...

Page 9: ...h to the flue collar of the stove ad extend straight up through the ceiling and the roof Make sure all the manufacturers specifications are followed closely especially when passing through any combustible walls ceilings or roof Normally an installation using manufacturer s chimney is beyond the expertise of the do it yourselfer Jacket Installation An optional jacket is available for your Cricket w...

Page 10: ...the R value of the proposed alternate floor protector a Use the formula in step 1 to convert values not expressed as R b For multiple layers add R values of each layer to determine the overall R value 3 If the overall R value of the system is greater than the R value of the specified floor protector the alternate is acceptable EXAMPLE The specified floor protector should be 3 4 inch thick material...

Page 11: ...temperature paint is bonding to the metal It is normal will stop when the paint is cured and will reoccur every time you repaint or touch up the paint on your stove 1 Crumble three or four full sheets of newspaper and place them on the firebrick floor of your Sierra stove 2 Crisscross two layers of dry kindling on the paper Add a few larger splits of dry wood on top of the kindling 3 Make sure the...

Page 12: ...ned or back draft whether or not there is combustion present 3 Opening a window slightly on a calm windless day alleviates any of the above symptoms 4 The house is equipped with a well sealed vapor barrier and tight fitting windows and or has any powered devices that exhaust house air 5 There is excessive condensation on windows in winter 6 A ventilation system is installed in the house b If these...

Page 13: ... a Limited Five Year W arranty Please read it carefully fill out the short registration form and return it within 30 days of purchase to Sierra Products Inc 5061 Brooks St Ste B Montclair CA 91763 Keep a Hotter Fire for Cleaner Glass Here are nine hints for keeping your window glass as clean as possible 1 A hotter fire near the window keeps it clean don t expect any stove window to stay perfectly ...

Reviews: