4300 Wood Stove Series (ACC)
B. Outside Air Kit Installation
1. Remove all materials from packing box.
2. Using a #2 Phillips screw driver attach the fl ex adapter
to the stove using 4 screws.
Figure 14.1.
3. For
fl oor installations remove circular” knock-out” in the
base of the pedestal.
4.
Floor & Rear Installation:
Cut a 4 inch (102mm)
hole in outside wall or fl oor to accommodate outside
air piping. Use 4 inch (102mm) aluminum metal fl ex or
rigid piping to directly connect outside air to appliance
intake. Use the supplied termination cap with a rodent
screen. Seal between the wall (or fl oor) and the pipe
with silicone to prevent moisture penetration.
Items Needed for Installation (not supplied)
• 4 inch fl ex aluminum pipe, or if using alternate material,
then it shall be made from durable, non-combustible,
heat resistant material up to 350
o
F. Cut the pipe to
the required length for your installation.
• Phillips head screw driver
•
Silicone
sealant
• Drills and saws necessary for cutting holes through
the wall or fl ooring in your home.
Figure 14.1 - Floor & Rear Installation
A source of air (oxygen) is necessary in order for combus-
tion to take place. Whatever combustion air is consumed
by the fi re must be replaced. Air is replaced via air leak-
age around windows and under doors. In homes that have
tightly sealed doors and windows, an outside air source is
needed. An optional Outside Air Kit is available.
WARNING
Do not draw outside combustion air from:
• Wall,
fl oor or ceiling cavity
• Enclosed space such as an attic or garage
• Close proximity to exhaust vents or
chimneys
Fumes or odor may result
Fire Risk.
Asphyxiation Risk.
Asphyxiation Risk.
Outside air inlet must be located to prevent block-
age from:
• Leaves
•
Snow or ice
• Other
debris
Block may cause combustion air starvation
Smoke spillage may set off alarms or irritate sensi-
tive individuals.
WARNING
Asphyxiation Risk.
Length of outside air supply duct shall NOT exceed
the length of the vertical height of the exhaust fl ue.
•
Fire will not burn properly
•
Smoke spillage occurs when door is opened due
to air starvation.
WARNING
Included in OAK-ACC:
Termination cap, (2) wire ties, flex
adapter, and fasteners
Included in SRV7033-041
:
Cover plate and sealing rope (see
Floor Installation Alternative below,
Figure 14.2
)
Figure 14.2 - Floor Installation Alternative
5.
Floor Installation Alternative:
In some instances you may
not be able to install the fl ex pipe as show in
Figure 14.1.
If that is the case, you will need to order SRV7033-041
which includes a cover plate and sealing rope as shown in
Figure 14.2.
The goal is to seal the pedestal so no room
air can leak into the pedestal or cold air infi ltration.
Summary of Contents for 4300 Series
Page 40: ...Page 40 7037 135L August 3 2015 ...
Page 41: ...August 3 2015 7037 135L Page 41 ...
Page 42: ...Page 42 7037 135L August 3 2015 ...
Page 43: ...August 3 2015 7037 135L Page 43 ...
Page 45: ...August 3 2015 7037 135L Page 45 ...
Page 46: ...Page 46 7037 135L August 3 2015 ...
Page 47: ...August 3 2015 7037 135L Page 47 ...
Page 48: ...Page 48 7037 135L August 3 2015 ...
Page 49: ...August 3 2015 7037 135L Page 49 ...
Page 50: ...Page 50 7037 135L August 3 2015 4300 Wood Stove Series ACC C Warranty Policy ...
Page 51: ...August 3 2015 7037 135L Page 51 4300 Wood Stove Series ACC ...