background image

 

154.013UK User Manual 

DMX Connection 
 

The B12P has a male XLR and female XLR on the rear panel (1, 4) for DMX512 control or 
connection to other B12P units for Master/Slave operation. Connect in sequence from 

female XLR to male XLR using good quality 3-pin XLR leads which are suitable for DMX. 
 

DMX Functions 

 

Channel 

Value 

Description 

CH1 

000 - 010 

No function 

011 - 050 

Auto program 1 

051 - 100 

Auto program 2 

101 - 150 

Auto program 3 

151 - 200 

Auto program 4 

201 - 255 

Auto program 5 

CH2 

000 - 039 

All colours 

040 - 049 

Red 

050 - 059 

Green 

060 - 069 

Blue 

070 - 079 

Yellow 

080 - 089 

Cyan 

090 - 099 

Purple 

100 - 109 

White 

110 - 119 

Red + Green 

120 - 129 

Red + Blue 

130 - 139 

Red + White 

140 - 149 

Green + Blue 

150 - 159 

Green + White 

160 - 169 

Blue + White 

170 - 179 

Red + Green + White 

180 - 189 

Red + Blue + White 

190 - 199 

Green + Blue + White 

200 - 209 

Red + Green + Blue 

210 - 255 

Red + Green + Blue + White 

CH3 

000 - 255 

Speed setting 

CH4 

000 - 255 

Master dimming 

CH5 

000 - 255 

Red dimming 

CH6 

000 - 255 

Green dimming 

CH7 

000 - 255 

Blue dimming 

CH8 

000 - 255 

White dimming 

Summary of Contents for B12P

Page 1: ...B12P Item ref 154 013UK Rechargeable Mini PAR Light User Manual Version 1 0 ...

Page 2: ...ock do not expose any components to moisture If liquids are spilled on the casing stop using immediately allow unit to dry out and have checked by qualified personnel before further use Avoid impact extreme pressure or heavy vibration to the case No user serviceable parts inside Do not open the case refer all servicing to qualified service personnel Safety Check for correct mains voltage and condi...

Page 3: ...ternal Settings Using the menu buttons 6 the B12P can be set to run in various modes These are outlined in the table below Function Display Press Up Down Press Enter Up Down DMX address setting DMX start address IP slave ID setting Auto 1 static colours Colours setting Auto 2 colour change Speed setting Auto 3 fade programs Colours setting flashing Speed setting Auto 4 sound activated Sequence set...

Page 4: ... program 2 101 150 Auto program 3 151 200 Auto program 4 201 255 Auto program 5 CH2 000 039 All colours 040 049 Red 050 059 Green 060 069 Blue 070 079 Yellow 080 089 Cyan 090 099 Purple 100 109 White 110 119 Red Green 120 129 Red Blue 130 139 Red White 140 149 Green Blue 150 159 Green White 160 169 Blue White 170 179 Red Green White 180 189 Red Blue White 190 199 Green Blue White 200 209 Red Green...

Page 5: ...oved to activate the CR2025 button cell Point the handset toward the front of the B12P unit at a range of no more than 5m for remote control Master slave operation A B12P fixture operating in one of the standalone modes may be connected onto further B12P units by DMX lead XLR XLR as a master unit The slave units must be set to IP mode to mimic the operation of the master unit The LED display will ...

Page 6: ...attery life 3 4 hours Recharge time 5 hours Dimensions 90 x 120mmØ Weight 437g Disposal The Crossed Wheelie Bin symbol on the product means that the product is classed as Electrical or Electronic equipment and should not be disposed with other household or commercial waste at the end of its useful life The goods must be disposed of according to your local council guidelines Errors and omissions ex...