background image

14

Connections

AC Power Cord

Insert the molded receptacle of the AC power cord into 
the AC power inlet on the back of the BASIS 914lz. Plug 
the AC line connector into the AC outlet. The power 
supply will accept from 100 to 240 Volts AC, 47 to 440 
Hertz, without any changes. If a different type of IEC 
power cord is required than supplied with your 914lz, 
contact QSC’s Technical Services Department.

CobraNet

Connect one end of a category-5 cable terminated with 
a RJ45 plug into the 

CobraNet

 receptacle. Insert the 

RJ45 plug into the receptacle with the lock-tab oriented 
toward the bottom of the BASIS 914lz and push firmly 
until the connector locks into place (usually an audible 
“click” can be heard). Connect the other end to the 
appropriate CobraNet network port.

QSControl

Connect one end of a category-5 cable terminated with 
an RJ45 plug into the 

QSControl

 receptacle. Insert the 

RJ45 plug into the receptacle with the lock-tab oriented 
toward the bottom of the BASIS 914lz and push firmly 
until the connector locks into place (usually an audible 
“click” can be heard). Connect the other end to the 
appropriate QSControl.net network port.

Analog Audio Inputs

Four balanced combo (XLR/TRS) inputs are provided, 

CH 

1 INPUT

 - 

CH 4 INPUT

. They accept line level signals. 

Plug the input signal XLR or 1/4” TRS connectors into 
the input receptacles. Connection pin-out is printed on 
the rear label for reference. Refer to the illustrations for 
balanced and unbalanced connections. Use balanced 
audio inputs whenever possible.

Omni In

The

 

two

 Omni In

 

connectors are two-pin terminal block 

connectors. They accept contact closure, TTL logic sig-
nals, 0-5 VDC control voltages, or 10k ohm variable 
resistors. The contact closure and logic devices accom-
modate on/off or state-change events; the variable 
resistor input provides full 8-bit resolution allowing for 
incremental-change events. Refer to the illustrations for 
connection recommendations. NOTE! +48 volts is the 
absolute maximum that can be applied to the + pin 
without damage. Voltage is with respect to chassis or 
the - pin.

Analog audio input- bal-
anced connection.

CobraNet and QSControl 
connection. Accepts rugge-
dized or normal shell-less 
RJ45 plugs.

Omni In connections. Vari-
able input must be 10k ohm 
variable resistor. Contact clo-
sure input can be a switch or 
relay contacts. These inputs 
can operate software 
“devices”. Negative (-) termi-
nal is at chassis potential.

Analog audio input- unbal-
anced connection. Note 
jumper wire between - and 
ground.

Summary of Contents for BASIS 914lz

Page 1: ...TD 000200 00 rev B BASIS 914lz 4X16 CobraNet Enabled Control and Monitoring Signal Processor Hardware Manual TD 000200 00...

Page 2: ...cord 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE...

Page 3: ...interface for accessing a few critical functions A single QSControl net server computer can support several clients running QSC s latest Venue Manager software Thus the sound system can be operated v...

Page 4: ...an be easily updated over the network In the future QSC will be adding new capabilities to both BASIS and QSControl net Our latest code releases and access to up to date information on BASIS and QSCon...

Page 5: ...ing to the proper rules To learn more about CobraNet and appropriate network topologies please visit http www qscaudio com products network resources htm and http www peakaudio com CobraNet background...

Page 6: ...loyments QSControl net is a TCP IP standards compliant network system and therefore supports operation on network repeaters switches and routers When implementing the Two Wire Interface the QSControl...

Page 7: ...would have to physically connect your computer first to one BASIS box and then to the other With this elementary connection you don t have a true network It is just like making RS 232 connections exc...

Page 8: ...riate destination anywhere on the network Though the example shows only two BASIS 914lz units as many devices may be connected as there are available switch ports All BASIS units will be able to commu...

Page 9: ...ol net traffic and a separate VLAN for CobraNet audio traffic This config uration essentially provides a dedicated network for BASIS 914lz control and monitoring including the system controller and a...

Page 10: ...ith its own network switch Therefore traffic segmentation is physical rather than logical Example 5 also pro vides an additional level of fault tolerance although at the expense of additional network...

Page 11: ...ment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack Mounting Rack mount...

Page 12: ...ws 95 98 and ME platforms are not supported Note If system is used for real time adjustments and configuration of audio systems we recommend all Windows Power Options located in the Windows Control Pa...

Page 13: ...ntroller computer CobraNet Connection Loss If you are operating with a valid CobraNet network and the connection to the network is disrupted audio will momentarily mute allow ing the BASIS 914lz to sy...

Page 14: ...Analog Audio Inputs Four balanced combo XLR TRS inputs are provided CH 1 INPUT CH 4 INPUT They accept line level signals Plug the input signal XLR or 1 4 TRS connectors into the input receptacles Con...

Page 15: ...then push into the receptacle until it is firmly seated tighten the retaining screws finger tight LED Indicators When the BASIS 914lz is plugged into a properly functioning AC outlet it will power up...

Page 16: ...er side of the display are used to navigate through the menus The rotary select accept knob is active for many displayed items allowing you to scroll through choices by rotating the control and accept...

Page 17: ...creen accessed becomes the new power up default Boot Screen Right side buttons serve as up down navigation Arrow characters indicate right side button context If additional menus are available the arr...

Page 18: ...ecify the installation directory or accept the default location 9 You will be prompted to select an installation accessible by everyone non secure or an installation accessible only to you secure Sele...

Page 19: ...applied to the BASIS 19 Click on the sign of the BASIS 914lz in the inventory root then the sign of the Flashed Configs Click on the config with the loudspeaker icon A view of applicable device tabs...

Page 20: ...the network This is currently 16 bit 20 bit and 24 bit Audio via inbound bundles may be in any combination of these resolu tions and the BASIS will process the data accordingly All DACs will process...

Page 21: ...unicate with the BASIS 914lz if it is in safe mode You may communicate only using TFTP Telnet or RS 232 RS 232 Serial Port I O Interface The RS 232 connector on the rear panel is used as a serial port...

Page 22: ...d click OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the lett...

Page 23: ...opening a Telnet session 1 To open the Telnet session Click START select RUN type Telnet followed by a space then the IP address of the BASIS 914lz you want to communicate with in the text box and cli...

Page 24: ...u 5 7 11 8 21 3 27 3 dBV 3 5 9 5 19 1 25 1 Program Outputs 16 Connector Type 8 HD 15 dataport connections Cable Type QSC DataPort cable QSC p n DPC x x designates cable length in feet Available stock...

Page 25: ...passive resistive controls RS 232 Port Female DB9 Connector QSControl net Neutrik Ethercon RJ45 Ruggedized Data Connector CobraNet Neutrik Ethercon RJ45 Ruggedized Data Connector Indicators QSControl...

Page 26: ...26 Dimensions...

Page 27: ......

Page 28: ...ts suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products wi...

Reviews: