INST APD0595 A140618 Wireless Smoke Heat Alarm Install Guide

interference that may cause undesired operation of the device.
This equipment has been tested and found to comply with the limits 
for  a  Class  B  digital  device,  pursuant  to  Part  15  of  FCC  Rules.  These 
limits  are  designed  to  provide  reasonable  protection  against  harmful 
interference in a residential installation. This equipment generates, uses 
and can radiate radio frequency energy and if not installed and used 
in  accordance  with  the  instructions,  may  cause  harmful  interference 
to  radio  communications.  However,  there  is  no  guarantee  that 
interference will not occur in a particular installation. If this equipment 
does cause harmful interference to radio or television reception, which 
can  be  determined  by  turning  the  equipment  off  and  on,  the  user  is 
encouraged  to  try  to  correct  the  interference  by  one  or  more  of  the 
following measures:

•  Reorient or relocate the receiving antenna.
•  Increase the separation between the equipment and the receiver
•  Connect the equipment into an outlet on a circuit different from 

that to which the receiver is connected.

•  Consult  the  dealer  or  an  experienced  radio/television  technician 

for help

“For your information, The National Fire Alarm Code, NFPA 72, reads as 
follows:
“11.5.1 Required Detection.”
“Where required by applicable laws, codes, or standards for a speci

fi

 c 

type of occupancy, approved single- and multiple-station smoke alarms 
shall be installed as follows:

1.  In a sleeping rooms and guest rooms
2.  Outside of each separate dwelling unit sleeping area, within 6.4 m 

(21 ft) of any door to a sleeping room, the distance measured along 
a path of travel

3.  On every level of a dwelling unit, including basements
4.  On every level of a residential board and care occupancy (small 

facility), including basements and excluding crawl spaces and un

fi

  

nished attics

5.  In the living area(s) of a guest suite
6.  In the living area(s) of a residential board and care occupancy.

(Reprinted with permission from NFPA 72®, National Fire Alarm Code 
Copyright  ©  2007  National  Fire  Protection  Association,  Quincy,  MA 
02269. This reprinted material is not the complete and of

fi

  cial position 

of the National Fire Protection Association, on the referenced subject 
which is represented only by the standard in its entirety.)
(National Fire Alarm Code® and NFPA 72

®

 are registered trademarks of 

the National Fire Protection Association, Inc., Quincy, MA 02269.) 

15

Guide d'installation du détecteur de chaleur et de fumée sans 

fi

 l INST APD0595 A140618

4.  Réinstallez le détecteur sur la base de montage en tournant le détecteur 

dans le sens horaire jusqu’à ce que les repères soient alignés.

5.  Après la mise sous tension, la DEL verte devrait clignoter une fois toutes 

les 12 secondes environ, pour indiquer un fonctionnement normal. Si les 
piles ne sont pas correctement installées, le détecteur ne fonctionnera pas 
et les piles risquent d'être endommagées. Si vous ne parvenez pas à mettre 
le détecteur sous tension, véri

fi

 ez que les piles sont correctement installées 

et qu'elles sont bien chargées.

6.  Testez le détecteur (comme décrit plus loin).

DES EXPOSITIONS CONSTANTES À DES TEMPÉRATURES ÉLEVÉES OU BASSES 
OU À UNE HUMIDITÉ ÉLEVÉE PEUVENT RÉDUIRE LA DURÉE DE VIE DES PILES.

PROGRAMMATION

Reportez-vous au guide de programmation approprié du panneau de commande 
compatible pour connaître la procédure adéquate et requise pour enregistrer le 
détecteur de fumée/chaleur sans 

fi

 l dans le système.

EMPLACEMENTS  RECOMMANDÉS  POUR  LE  DÉTECTEUR  DE  CHALEUR  ET  DE 
FUMÉE

Selon  la  National  Fire  Protection  Association  (NFPA),  la  principale  menace 
d’incendie dans une maison d'habitation survient la nuit, quand tout le monde 
est  endormi.  La  menace  principale  pour  les  personnes  se  trouvant  dans  les 
chambres à coucher vient des incendies survenant dans le reste de l’habitation. 
Le  meilleur  emplacement  pour  un  détecteur  de  fumée  se  situe  donc  entre 
les  chambres  à  coucher  et  le  reste  de  l’habitation.  Dans  les  habitations  avec 
seulement une chambre à coucher sur un étage, le détecteur doit être installé 
tel que l'indique la Figure 2. Dans les maisons d'habitations ayant plus d’une 
chambre  à  coucher  ou  des  chambres  sur  plus  d’un  étage,  il  est  nécessaire 
d'installer plus d’un détecteur de fumée, comme le démontre la Figure 3.
En plus des détecteurs de fumée installés hors des chambres à coucher, l’appareil 
doit être installé à chaque étage supplémentaire de la maison, y compris au sous-
sol. Ces installations sont illustrées dans la Figure 4. Le détecteur de fumée de 
la salle de séjour doit être installé dans le salon ou près de l’escalier menant au 
niveau supérieur, ou aux deux endroits. Le détecteur de fumée du sous-sol doit 
être installé tout près de l’escalier qui mène à l'étage supérieur. S’il est installé sur 
un plafond à solives apparentes, le détecteur devrait être placé sous les solives. 
Le détecteur doit être placé par rapport à l’escalier de manière à intercepter la 
fumée provenant d’un incendie au sous-sol avant que la fumée n’entre dans 
l’escalier.
Les détecteurs de fumée sont optionnels s’il n’y a pas de porte entre la salle de 
séjour et la salle de jeux (Figure 5). La fumée d’un incendie s’élève généralement 
au plafond, se répand sur toute la surface du plafond et commence à s'amonceler 
à partir du plafond. L’angle où le plafond et le mur se rejoignent est un espace 

Summary of Contents for IQSmoke

Page 1: ...ns an integrated fixed 41 F temperature freeze sensor that will send a warning signal based on temperature detected This detector is designed to provide protection with 70 foot spacing capability The detector can send alarm tamper and battery condition messages to the system s receiver Refer to the wireless system s instruction for the maximum number of transmitters that can be supported CONTENTS ...

Page 2: ...oke Heat Alarm contains a sounder which generates the ANSI S3 41 temporal 3 pattern in an alarm condition In alarm a message is also sent to the control panel and the detector s ID is displayed at the console During an alarm condition pressing the detector s hush button will silence the sounder see table below The mounting base installation is simplifi ed by the incorporation of features compatibl...

Page 3: ...anel will display a loss of supervision message Low Battery Detection The Wireless Smoke Heat Alarm is powered by 3 AAA Duracell Procell or 3 AAA Energizer E92 batteries included The detector regularly checks for a low battery If a low battery is detected the transmitter sends a low battery message to the control panel which displays the detector s ID at low battery In addition the yellow LED of t...

Page 4: ...ions non autorisés pourraient entraîner l annulation de l autorisation d exploiter l équipement Cetappareilestconformeàlapartie15delaréglementationdelaFCCetauxnormes RSS sur les appareils exempts de licence d Industrie Canada Son fonctionnement est soumis aux deux conditions suivantes 1 Ce dispositif ne doit pas causer d interférences nuisibles et 2 cet appareil doit accepter toute interférence re...

Page 5: ...incluses trois 3 piles AAA PC2400 Duracell Procell ou trois 3 piles AAA Energizer E92 Liste de matériels homologués réglementaires UL 217 Garantie deux 2 ans Accessoires inclus Trousse de matériel de montage INFORMATIONS RÉGLEMENTAIRES 5 penetrating In most fires this dead air space measures about 0 1m 4in along the ceiling from the corner and about 0 1m 4in down the wall Detectors should not be p...

Page 6: ...échapper même si elles sont averties suffisamment tôt pour qu une évacuation soit possible Pour ces personnes d autres stratégies tellesquedesmesuresdeprotection uneévacuationouunsecoursassistéseraient nécessaires Un détecteur alimenté par piles doit avoir des piles du type spécifié en bon état et convenablement installées Les détecteurs de fumée doivent être régulièrement testés pour s assurer qu...

Page 7: ...ur L extérieur du détecteur peut être essuyé avec un chiffon humide Après nettoyage réinstallez et testez votre détecteur à l aide du bouton de test Si le nettoyage ne restaure pas le fonctionnement normal de l alarme le détecteur doit être remplacé 7 INST APD0595 A140618 Wireless Smoke Heat Alarm Install Guide TESTING THE DETECTOR NOTE Before testing notify the central station that the detector s...

Page 8: ... or 2 minutes Planning and practicing for fire conditions with a focus on rapid exit from the residence are important Drills should be held so that all family members know the action to be taken SAFETY TIPS Make a home escape plan Draw a map of your home showing all doors and windows Discuss the plan with everyone in your home 17 Guide d installation du détecteur de chaleur et de fumée sans fil IN...

Page 9: ... DE FUM E SgIL NgY A PAS DE PORTE ENTRE LE SALON ET LA SALLE DE JEUX NSTALLATION D UN D TECTEUR DE FUM E REQUISE NTR E HAMBRE 3ALON 3ALLE Ë MANGER AVE NTR E HAMBRE 100 4 i Fig 5 QVWDOODWLRQ GDQV XQH PDLVRQ j GHPL QLYHDX Fig 4 8Q GpWHFWHXU LQVWDOOp j FKDTXH pWDJH 9 INST APD0595 A140618 Wireless Smoke Heat Alarm Install Guide Know at least two ways out of every room if possible Make sure all doors a...

Page 10: ...a base de montage en tournant le détecteur dans le sens horaire jusqu à ce que les repères soient alignés 5 Après la mise sous tension la DEL verte devrait clignoter une fois toutes les 12 secondes environ pour indiquer un fonctionnement normal Si les piles ne sont pas correctement installées le détecteur ne fonctionnera pas et les piles risquent d être endommagées Si vous ne parvenez pas à mettre...

Page 11: ...lacez les piles dès que les bips sonores recommencent Assurez vous de remplacer les anciennes piles par des neuves INSTALLATION ET REMPLACEMENT DES PILES Pour remplacer les piles 1 Déposez le détecteur de son socle de fixation en le tournant dans le sens antihoraire Enlevezlespilesetmettez lesaurebutselonlesréglementations locales 2 Afin de garantir une mise hors tension appropriée attendez 20 sec...

Page 12: ...r le bouton pour l arrêter pendant 5 à 10 minutes Test de fumée Clignote en rouge chaque seconde ANSI S3 41 temporel 3 appuyez sur le bouton pour l arrêter pendant 5 à 10 minutes Tester le détecteur Clignote en rouge chaque seconde ANSI S3 41 temporel 3 Alarme de gel Clignote en jaune 3 fois toutes les 4 secondes Désactivé Défaut du détecteur Clignote en jaune toutes les 4 secondes Un bip sonore t...

Reviews: