background image

qolsys.com/qz2160840

Force Calibration: 

- Force calibration is set automatically when first 

actuated.   

- To manually re-calibrate, Tap and hold the touch 

sense button for 5 beeps, then quickly Tap it 5 
times in a row.  The water valve will open/close 
1 to 2 cycles, followed by 2 beeps.

If you are installing the IQ Water Valve 
outdoors, the touch sense button 
should be disabled to prevent rain 
drops from activating it.

Document#: IQWATERVALVE-QG-12-20 
Revision#: 06/01/21 
Issue Date: JUNE 2021 
Qolsys Product #: QZ2160-840 & QZ2160-724

[email protected]

Qolsys Inc. proprietary.   

Reproduction without permission is not permitted.

FCC ID: 2AUZX-BVSZWU

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired 

operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference 

that may cause undesired operation of the device.

Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences et (2) cet appareil doit accepter toute 

interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil.

CONTACT TECH SUPPORT

GOT QUESTIONS?

TROUBLESHOOTING

OUTDOOR INSTALLS

Touch 
Sense 

Button

To Disable the Button: 

- Tap and hold the touch sense 

button for 3 beeps, then quickly 
Tap 3 times in a row.

- If successful, the Yellow LED will flash once, then the Red LED 

with 1 beep.  The LED will then slowly flash Yellow indicating the 
touch sense button has been locked.

To Re-Enable the Button: 

- Tap and hold the touch sense button for 3 beeps, then quickly Tap 

3 times in a row. 

- If successful, the Yellow LED will flash once, then the Red LED 

with 3 beeps.  The LED will then slowly flash Green (if enrolled) 
indicating the touch sense button has been unlocked.

LED Status: 

- Flashing Yellow:  Not yet included into the Z-Wave network or the 

touch sense button has been disabled. 

- Flashing Green:  Included into the Z-Wave network.

Factory Default: 

- Option 1:  Use the IQ Panel to “Clear” the IQ Water Valve.  This will 

remove it from the Z-Wave network and restore factory defaults. 

- Option 2:  Tap and hold the touch sense button for 10 beeps, then 

quickly Tap it 5 times in a row.  If successful the Yellow LED will 
flash once, followed by the Green LED and a long beep.

Scan for more info

Summary of Contents for IQ Water Valve

Page 1: ...2160 724 EU Dimensions 14 8 x 9 6 x 13 3mm Weight 603g Waterproof Dustproof IP66 Usage For Indoor Outdoor Water Valve On Off Operating Temperature 14 122 F 10 50 C Relative Humidity 8 80 Operating Distance Up to 130ft indoors and 450ft outdoors Frequency Type Z Wave Plus 700 series 908 4 MHz US 868 42 MHz EU Motor Torque Adaptive output max 8n m Touch Sense Button x1 LED Indicator 3 color LED Gree...

Page 2: ...dle Align the fork with the handle and press down firmly to engage spring loaded gear Then tighten thumb screws STEP 4 PLUG IN TO AN OUTLET STEP 2 POSITION THE IQ WATER VALVE OVER THE TOP OF THE HANDLE Connect the 5 5mm circular power jack from the DC adapter turn clockwise to secure water seal cover Then plug in to an outlet On lower profile valves if needed insert the spacer between the fork and...

Page 3: ...s of the DSK or scan the QR Code from the box x1 Tap the touch sense button 1 time quickly to open the valve The IQ Water Valve will auto calibrate based on the amount of force needed to open close the ball valve Touch it again 1 time to close the valve Open close the valve from the Panel Settings Other Z Wave Devices to ensure proper communication range and function This is a quick guide for expe...

Page 4: ...e undesired operation of the device Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS s Son fonctionnement est soumis aux deux conditions suivantes 1 cet appareil ne doit pas provoquer d interférences et 2 cet appareil doit accepter toute interférence y compris celles pouvant causer un mauvais fonctionnement de l appareil CONTACT TECH SUPPORT GOT QUESTIONS TROUBLESHOO...

Reviews: