background image

TURN MAIN WATER 
VALVE TO THE OFF 
POSITION

STEP 

3

PRESS DOWN 
FIRMLY & TIGHTEN 
THUMB SCREWS 

STEP 

1

Plug in the IQ Siren 

at desired location

This is a quick guide for experienced installers only.  Refer to http://dealers.qolsys.com (login required) 

Make sure the thumb 

screws are facing the 

same side as the water 

valve handle

Align the fork with the handle and press down firmly to 
engage spring loaded gear.  Then tighten thumb screws

STEP 

4

PLUG-IN TO 
AN OUTLET

STEP 

2

POSITION THE  IQ WATER 
VALVE OVER THE TOP OF 
THE HANDLE

Connect the 5.5mm circular power 

jack from the DC adapter, turn 

clockwise to secure water seal cover.  

Then plug-in to an outlet

On lower profile valves, 

if needed, insert the 

spacer between the fork 

and the water valve 

handle.   

This spacer ensures the 

fork will engage the 

spring loaded gear inside 

the IQ Water Valve

Summary of Contents for IQ Water Valve

Page 1: ...2160 724 EU Dimensions 14 8 x 9 6 x 13 3mm Weight 603g Waterproof Dustproof IP66 Usage For Indoor Outdoor Water Valve On Off Operating Temperature 14 122 F 10 50 C Relative Humidity 8 80 Operating Distance Up to 130ft indoors and 450ft outdoors Frequency Type Z Wave Plus 700 series 908 4 MHz US 868 42 MHz EU Motor Torque Adaptive output max 8n m Touch Sense Button x1 LED Indicator 3 color LED Gree...

Page 2: ...dle Align the fork with the handle and press down firmly to engage spring loaded gear Then tighten thumb screws STEP 4 PLUG IN TO AN OUTLET STEP 2 POSITION THE IQ WATER VALVE OVER THE TOP OF THE HANDLE Connect the 5 5mm circular power jack from the DC adapter turn clockwise to secure water seal cover Then plug in to an outlet On lower profile valves if needed insert the spacer between the fork and...

Page 3: ...s of the DSK or scan the QR Code from the box x1 Tap the touch sense button 1 time quickly to open the valve The IQ Water Valve will auto calibrate based on the amount of force needed to open close the ball valve Touch it again 1 time to close the valve Open close the valve from the Panel Settings Other Z Wave Devices to ensure proper communication range and function This is a quick guide for expe...

Page 4: ...e undesired operation of the device Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS s Son fonctionnement est soumis aux deux conditions suivantes 1 cet appareil ne doit pas provoquer d interférences et 2 cet appareil doit accepter toute interférence y compris celles pouvant causer un mauvais fonctionnement de l appareil CONTACT TECH SUPPORT GOT QUESTIONS TROUBLESHOO...

Reviews: